E-
11
ENGLISH
Drain Hose
Drilling a Hole in the Wall
◆
Drill a hole of 70mm in diameter to the outside.
◆
The drilling should be done at a distance of less than
150mm from the floor facing the indoor unit.
◆
Extend the drain hose to the drain hose connected to
the drain pan, and fix it with the tape or a cable-tie to
prevent separation. Then make a covering of it so
that water cannot flow outwardly.
CAUTION
1. As the draining is of natural drain type, make the drain hose direct downward.
2. If there is any foreign substance in the drain plate, it may clog the drain pipe. Therefore, be sure to
remove the foreign substance inside after installation.
3. After completion of installation, be sure to pour water into the drain pan, and then check the draining
condition. (There is no problem in draining when the draining is completed within 20 seconds.)
Foamed Polyethylene
Insulator
Vinyl Chloride
(Outer diameter ø16mm)
Piping Material
Drain hose
Drain pan
Indoor and outdoor
unit connection
Insulation
Band
Less than
150mm
ø70mm
APV48QOAN_E_IM_00000 2008.10.20 11:5 PM Page 11