background image

QUESTIONS OR COMMENTS?

COUNTRY 

CALL 

OR VISIT US ONLINE AT 

EGYPT

08000-7267864 

16580

www.samsung.com/eg/support

ALGERIA

021 36 11 00

www.samsung.com/n_africa/support

IRAN

021-8255 [CE]

www.samsung.com/iran/support

SAUDI ARABIA

8002474357

www.samsung.com/sa/support 

www.samsung.com/sa_en/support (English)

PAKISTAN

0800-Samsung (72678) 

www.samsung.com/pk/support

TUNISIA

80-1000-12 

www.samsung.com/n_africa/support

U.A.E

800-SAMSUNG (800 - 726 7864)

www.samsung.com/ae/support (English) 

www.samsung.com/ae_ar/support (Arabic)

OMAN

800-SAMSUNG (800 - 726 7864)

KUWAIT

183-CALL (183-2255)

BAHRAIN

8000-GSAM (8000-4726)

QATAR

800-CALL (800-2255) 

TURKEY

444 77 11

www.samsung.com/tr/support

JORDAN

0800-22273 

06 5777444

www.samsung.com/Levant/support 

(English)

SYRIA

18252273

www.samsung.com/Levant/support 

(English)

MOROCCO

080 100 22 55

www.samsung.com/n_africa/support

SOUTH AFRICA

0860 SAMSUNG  (726 7864)

www.samsung.com/support

BOTSWANA

8007260000

NAMIBIA

08 197 267 864

ZAMBIA

0211  350370

MAURITIUS

23052574020

REUNION

262508869

MOZAMBIQUE

847267864 / 827267864

NIGERIA

0800-726-7864

www.samsung.com/africa_en/support

Ghana

0800-10077 

0302-200077

Cote D’Ivoire

8000 0077

www.samsung.com/africa_fr/support

SENEGAL

800-00-0077

CAMEROON

7095-0077

KENYA

0800 545 545 

www.samsung.com/support

UGANDA

0800 300 300

TANZANIA

0800 755 755 / 0685 889 900

RWANDA

9999

BURUNDI

200

DRC

499999

SUDAN

1969

This product is not manufactured for Iran. SVC Warraty will not be 

applicable and the user will be responsible for service  

expenses when the product is used in Iran. 

PAC_아프리카 중동향AP80S0A_IBIM_34514A-02_EN.indd   56

2015-04-23   오후 2:19:01

Содержание AP80S0A Series

Страница 1: ...www samsung com Levant support English SYRIA 18252273 www samsung com Levant support English MOROCCO 080 100 22 55 www samsung com n_africa support SOUTH AFRICA 0860 SAMSUNG 726 7864 www samsung com s...

Страница 2: ...02 EN ES FR PT AR AP80S0A Series AP0AS0A Series Air Conditioner user installation manual imagine the possibilities ThankyouforpurchasingthisSamsungproduct PAC_ AP80S0A_IBIM_34514A 02_EN indd 57 2015 0...

Страница 3: ...Basic operation 12 Adjusting the air flow direction 14 Turbo operation 14 Smart saver operation 15 Timer function 15 Cleaning and maintaining the air conditioner 16 Troubleshooting 19 Safety precautio...

Страница 4: ...ult in electric shock fire explosion problems with the product or injury Install a switch and circuit breaker dedicated to the air conditioner X X Failing to do so may result in electric shock or fire...

Страница 5: ...FOR POWER SUPPLY CAUTION When not using the air conditioner for a long period of time or during a thunder lightning storm cut the power at the circuit breaker X X Failing to do so may result in elect...

Страница 6: ...ner for long periods of time in badly ventilated locations or near infirm people X X Since this may be dangerous due to a lack of oxygen open a window at least once an hour If any foreign substance su...

Страница 7: ...dge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with t...

Страница 8: ...e turned off If ELB have already been installed in the switch box of the building you don t need to install the auxiliary power switch Operational temperature and humidity range When the air condition...

Страница 9: ...de up down orientation Control panel Air outlet Air filter Removes the dust of incoming air Air intake Intakes the outdoor air To open the panel Hold the upper part of the panel and then pull it sligh...

Страница 10: ...air conditioner with the control panel if this function is set Press the Temp and Fan Speed buttons for 3 seconds f f You will hear ring and the Lock icon will appear on the indoor unit display f f On...

Страница 11: ...ease the temperature by 1 C 3 Press the Fan Speed button to adjust the fan speed f f Each time you press the Fan Speed button the fan speed will change in order of High Auto Low 4 Press the Mode butto...

Страница 12: ...ound Not supported by this model Turbo Long Turbo Set quick and powerful cooling Long Set the long function to spread out the cool air further away Not supported by this model Temperature Adjusts the...

Страница 13: ...rate automatically according to the desired temperature and current temperature and control the fan speed in Auto mode Dry In Dry mode indoor humidity can be removed efficiently to refresh the humid i...

Страница 14: ...eral type High Auto Low Duct type Turbo Auto High Auto Auto Dry Auto Fan General type Low High Duct type High Turbo Press the button to adjust the desired temperature Cool You can adjust the desired t...

Страница 15: ...ction provides you with quick and powerful cooling Press the button to select theTurbo operation f f will be displayed on the indoor unit display and theTurbo operation will operate for 30 minutes Can...

Страница 16: ...n also be adjusted Smart saver operation andTurbo operation cannot be selected at the same time Timer function You can turn the air conditioner off at your desired time Press the button when the air c...

Страница 17: ...you have a problem with the odor contact a service center Do not clean the control panel with alkaline detergent Do not clean the surface with sulfuric acid hydrochloric acid or organic solvent thinn...

Страница 18: ...is too heavy use warm water mixed with detergent Do not scrub the filter too hard since it may get damaged 3 Dry the air filter in a ventilated area f f Do not dry the air filter in a place with dire...

Страница 19: ...exchanger 2 Clean the condensate drain pipe 2 Outdoor unit Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with...

Страница 20: ...ng signal Cool air does not come out of the air conditioner Check if the set temperature is higher than the current temperature Press the Temp or button on the remote controller to set the temperature...

Страница 21: ...the status of the air conditioner usage especially when the outdoor temperature is below 20 C noise can be generated due to changes in refrigerant flow You don t have to worry since it is normal Water...

Страница 22: ...nits if damaged If problems occur switch the unit off and disconnect it from the power supply f f In order to prevent electric shocks fires or injuries always stop the unit disable the protection swit...

Страница 23: ...ions provided in the wiring diagram included in the manual f f Always verify that electric connections cable entry section of leads protections are compliant with the electric specifications and with...

Страница 24: ...30 when carrying it Do not lay the product down sideways f f The surface of the heat exchanger is sharp Be careful not to get injured during moving and installing the product When moving with a crane...

Страница 25: ...o obstacle against the wind around the air intake and air outlet f f Install the unit horizontally at a stable rigid place When installing the unit at a place subjected to oscillation noise may occur...

Страница 26: ...ace exposed to direct sunlight f f Choose a place where the unit could not come into contact with snow and rain f f For repair services and the ventilation secure service area as shown in the figure f...

Страница 27: ...t Sea breeze Sea f f If you cannot avoid installing the outdoor unit by the seashore construct a protection wall around to block the sea breeze Protection wall Outdoor unit Sea breeze Sea Protection w...

Страница 28: ...waves generate If not malfunction of the control system may occur due to the effect of the electromagnetic wave For example The remote control sensor of the indoor unit may not be received well of ele...

Страница 29: ...rformance designed Keep in mind that SAMSUNG logo is located on the front side of outdoor unit AP80S0 X When there are no tall obstacles around the outdoor unit f f Maximum height of the obstacle Fron...

Страница 30: ...more 500 or more 10 or more 200 or more Front Case 2 50 or more 50 or more Front 100 or more 500 or more Case 3 200 or more The height of the wall is unlimited 300 or more Pipe length between the ind...

Страница 31: ...In abnormally harsh environments such as windy areas sufficient countermeasures to guard against excessive wind should be taken to ensure the unit s correct operation When installing ducts The frame f...

Страница 32: ...install anti vibration pad or frame between the base ground and the bottom of the outdoor unit to prevent the vibration noise from transferring through the base ground Anchor bolt fixing dimensions F...

Страница 33: ...he outdoor unit cannot be fixed on the ground fix the side of the outdoor unit or use extra structure to fix it You must pay extra attention on waterproofing and constructing drainage on the ground wh...

Страница 34: ...oles for refrigerant pipes on the left right and rear side of the indoor unit and you may choose any one of the holes depending on your installation location Choose a side for the easier pipe connecti...

Страница 35: ...of the pipe exceeds 6m install S trap every 6m Indoor unit Less than 20m Less than 30m Indoor unit Outdoor unit Outdoor unit Less than 6m Indoor unit S trap Install S trap every 6m of height differen...

Страница 36: ...refrigerant pipe Outer diameter mm inch Minimum thickness mm Temper grade 6 35 1 4 0 7 C1220T O Soft 9 52 3 8 0 7 12 70 1 2 0 8 15 88 5 8 0 8 19 05 3 4 1 0 22 23 7 8 0 9 C1220T 1 2H Semi soft or C122...

Страница 37: ...en brazing the pipes as shown in the picture f f If you do not perform nitrogen flushing when brazing the pipes oxide may form inside the pipe It can cause the damage of the important parts such as co...

Страница 38: ...pipe Yoke Flaring bar Copper pipe Flare nut Outer diameter D mm Depth of the flare A mm Flare tool Clutch type Wing nut type 6 35 1 0 1 5 1 5 2 0 9 52 1 0 1 5 1 5 2 0 12 70 1 0 1 5 1 5 2 0 15 88 1 0...

Страница 39: ...no cracks when bending the pipe Do not fasten the flare nut with excessive strength Pipe bending 1 Perform bending of the pipe using the bender which has a specified bending radius 2 Be sure to take f...

Страница 40: ...on Insulation of the gas and liquid pipes can be in contact with each other but they should not be pressing each other When contacting the gas side and liquid side pipe use thicker insulation Insulati...

Страница 41: ...be no grounding effect Ground wire of telephone and lightning rod The electric potential of ground wire may rise abnormally when lightening strikes f f The ELB for ground fault protection should be c...

Страница 42: ...ut W 6 600 9 800 Running current A 12 0 16 5 Heating Power input W Running current A Starting current A Power cable Type Equivaletnt to H07RN F or higher Below 20m mm2 4 0 Not included 4 0 Not include...

Страница 43: ...for air conditioner Earth Earth Earth Earth Communication cable between indoor and outdoor unit Power supply cable Indoor unit Distributing board Outdoor unit Power cable When using power supply R S T...

Страница 44: ...16 5 16 22 22 24 Allowance mm 0 2 0 2 0 2 0 3 0 3 0 3 0 4 D Standard dimension mm 5 6 7 1 9 11 5 13 3 13 5 17 5 Allowance mm 0 3 0 2 0 3 0 2 0 3 0 2 0 5 0 2 0 5 0 2 0 5 0 2 0 5 0 4 d1 Standard dimensi...

Страница 45: ...thethickcableonthebottom Securethe powercablewiththecabletie Screw Tightening torque kgf cm M3 5 0 6 0 M3 5 8 0 10 0 M4 12 0 15 0 M5 20 0 25 0 M6 25 0 30 0 When removing the outer sheath of the power...

Страница 46: ...ing a circuit breaker that can cut the electric circuit in case of a short circuit the allowable grounding resistance can be 30 500 Note 2 Grounding at dry place f f The grounding resistance is should...

Страница 47: ...ities Gas pipe water pipe Service pipe underground cable If the grounding wire is paralle to the grounding pole for the lightning rod make sure they are at least 2m apart from each other Avoid sandy g...

Страница 48: ...he outdoor unit is done initially from the factory but you must test for gas leakage after the installation 1 Purge the pipe and run vacuum test Pressure should not increase for a minute 2 Insert the...

Страница 49: ...refrigerant based on the below pressure table Purpose of pressure table If additional refrigerant filling is needed due to the leakage of the refrigerant or re installation add refrigerant using press...

Страница 50: ...of the switch settings Disuse Use K2 Option Not set Always on K3 Option Not set Always on Disregard communication error K4 Use it for displaying the product in exhibition Do not use this setting othe...

Страница 51: ...splay 1 Cooling test operation 2 End KEY operation No display K3 Number of pressing KEY operation 7 Segment display 1 Reset operation Same as reset status K4 Number of pressing Displayed contents Disp...

Страница 52: ...u checked for any gas leakage Are the length and the height difference between the refrigerant pipes within the allowable range Have you properly insulated pipes Is the quantity of the additional refr...

Страница 53: ...mode Inspect the compressor sound during the initial operation If roaring sound is heard stop the operation If roaring sound is heard and the pressure does not change back lashing of the compressor ma...

Страница 54: ...rossing error E221 Outdoor temperature sensor Open or short E256 Discharge sensor Open or short E416 Compressor stop by discharge temperature s protection control E425 Reverse phase or phase open E451...

Страница 55: ...t both sides of core wire of the power cable into the connection sleeve f f Method 1 Push the core wire in to the sleeve from both sides After peeling off the tube wire you must insert a contraction t...

Страница 56: ...hod 2 5 Apply heat to the service tube to contract it Service tube 6 After tube contraction work is completed wrap it with the insulation tape to finish Insulation tape In case of extending the electr...

Отзывы: