30
Installation Procedure
English
Instal
lation Pr
oc
edur
e
Option
SEG13
SEG14
SEG15
SEG16
SEG17
SEG18
Explanation
PAGE
Use of external control
Setting the output of external
control / External heater signal /
Cooling operation signal /
Free Cooling control signal
S-Plasma ion
Buzzer control
Hours of filter usage
Indication
and Details
Indication Details Indication Details Indication
Details
Indication
Details
Indication Details Indication
Details
2
0
Disuse
0
External control
(Thermo On)
0
Disuse
0
Use
buzzer
2
1000 Hour
1
ON/OFF
control
1
External control
(Operation On)
2
External heater
signal (*4)
2
OFF
control
3
External heater
signal (*4)
4
Cooling operation
signal (*5)
1
Use
1
Disuse
buzzer
6
2000 Hour
3
Window
ON/OFF
control
5
Free Cooling control
(Cooling Thermo On) (*6)
6
Free Cooling control
(Cooling/Dry Thermo
On) (*6)
Option
SEG19
SEG20
SEG21
SEG22
SEG23
SEG24
Explanation
PAGE
Individual control of a
remote controller
Heating setting compensation / Removing condensate water
in heating mode
Adjusted EEV step of
stopped unit during
oil return /defrost
mode.
Motion detect sensor
Indication and
Details
Indication Details Indication Details Indication
Details
Indication Details Indication
Details
Heating Setting
Compensation
Removing Condensate
Water in Heating Mode
3
0 or 1
channel 1
0
Default
Disuse
0
Default
0
Disuse
1
2 °C
Disuse
1
Turn out in 30min.
without motion
2
channel 2
2
5 °C
Disuse
2
Turn out in 60min.
without motion
3
Default
Use (*7)
3
Turn out in 120min.
without motion
3
channel 3
4
Turn out in 180min.
without motion
4
2 °C
Use (*7)
1
Adjusted
EEV
positon
5
Turn out in 30min.
without motion or
*advanced function
4
channel 4
6
Turn out in 60min.
without motion &
*advanced function
5
5 °C
Use (*7)
7
Turn out in 120min.
without motion &
*advanced function
8
Turn out in 180min.
without motion &
*advanced function
* Advanced function: Controlling cooling/heating current or power saving with motion detect.
(*1)
When Cooling or dry mode is off. The indoor fan operate in setting minutes.
(*2)
Minimizing fan operation when thermostat is off
- Fan operates for 20 seconds at an interval of 5 minutes in heat mode.
- Fan stops or operates Ultra low in Cooling when thermostat is off.
(*3)
1: Fan is turned on continually when the hot water heater is turned on,
3: Fan is turned off when the hot water heater is turned on with cooling only indoor unit
Cooling only indoor unit: To use this option, install the Mode Select switch(MCM-C200) on the outdoor unit and fix
it as cool mode.
DVM TK Wind-Free 1way IM EN_DB68-07553A-00.indb 30
2017-12-01 오후 2:19:09