38
A
Setting an indoor unit address and
installation option (Cont.)
Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXX
Q
02 series installation option(Detailed)
F4
F3
F1
F2
V2
V1
1(L) 2(N)
2
1
HOT
COIL
AC
POWER
OUTDOOR
COMMUNICATION
Wire Remote
Controller
DC 12 V
* The output of hot coil terminal is AC 220 V / 230 V
(The same as Indoor Unit’s input Power)
COM1 COM2
(+) L
N
(-)
X
The external output of SEG15 is generated by MIM-B14 connection. (Refer to the manual of MIM-B14.)
Option SEG1
SEG2
SEG3
SEG4
SEG5
SEG6
Explanation
PAGE
MODE
-
Use of external room temperature
sensor / Minimizing fan operation
when thermostat is off
Use of central control
FAN RPM compensation
Indication
and Details
Indication Details Indication
Details
-
Indication
Details
Indication
Details
Indication
Details
Use of
External
room
temperature
sensor
Minimizing
fan operation
when
thermostat
is off
0
2
0
Disuse
Disuse
0
Disuse
0
Disuse
1
Use
Disuse
1
RPM
compensation
2
Disuse
Use (
*1
)
1
Use
2
High ceiling
KIT
3
Use
Use (
*1
)
Option SEG7
SEG8
SEG9
SEG10
SEG11
SEG12
Explanation
PAGE
Use of drain pump
Use of hot water
heater
EEV Step when heating
stops
Indication
and Details
Indication Details Indication
Details
Indication
Details
Indication
Details
1
0
Disuse
0
Disuse
0
Default
value
1
Use
1
Use (
*2
)
1
Noise
decreasing
setting
2
When an
indoor unit
stops, drain
pump will
operate for
3min
2
--
3
Use (
*2
)
X
The output of hot water heater in SEG9 is generated from the hot coil part of the terminal board in duct models.