Troubleshooting
Samsung Electronics
65
4-
5
-11 In
case
of
heating
at
the
cooling
mode
or
cooling
at
the
heating
mode
1
.
T
roub
l
eshooting
procedure
Change
the
setting
temperature
of
remote
contro
l
.
Operate
it
with
a
heating
mode
as
soon
as
the
defrosting
is
shed.
After
3
minutes,
coo
l
ing
and
heating
start
automatica
ll
y.
No
No
No
Yes
Yes
Yes
Is
the
T
hermo
?
Is
the
unit
in
the
defrosting
operation?
Is
the
compressor
in
3
minutes
Check
the
resistance
va
l
ue
of
4-WAY
va
l
ve
coi
l
.
G
o
to
the
next
page
4-WAY
va
l
ve
main
body
error
Attach
the
sensor
correct
l
y.
Over
shortage
of
the
refrigerant
Connect
the
connecter
correct
l
y.
4-WAY
va
l
ve
coi
l
error
Exchange
the
outdoor
PCB.
No
Yes
Yes
Yes
OK
Yes
No
No
No
N
G
No
Is
much
frost
in
the
indoor
heat
exchanger?
Does
the
4-WAY
va
l
ve
operate
norma
ll
y?
Is
the
outdoor
air
sensor
and
outdoor
heat
exchanger
attached
correct
l
y?
Is
the
4-WAY
va
l
ve
connector
connected
correct
l
y?
Dose
the
vo
l
tage
of
AC220
V
app
l
y
to
the
connector
of
4-WAY
va
l
ve
coi
l
during
the
operation?