Samsung AEX160EDEHA Скачать руководство пользователя страница 40

Samsung Electronics

39

Wired remote controller

 (cont.)

Error mode

Contents

Measure

Product operation in 

error condition

Error type

Outdoor unit/

Compressor/Indoor 

unit

COM1/COM2 cross installation 

error

Check that wired remote controller is connected to the 
COM2 terminal of the indoor unit

Normal operation

Wired remote 

controller error

Communication error between 

the Master and Salve wired 

remote controllers

Check  the option switch for defining the Master and 
salve(Only one Master can exist)

Normal operation

Wired remote 

controller error

Wired remote controller COM2 

option setting error 

Check that Com1, Com2 setting DIP switch is set to Com2

Normal operation

Wired remote 

controller error

5&0+;*$B60B(B$BLQGG

Содержание AEX160EDEHA

Страница 1: ...HYDRO UNIT 1 Precautions 2 Product Specifications 3 Disassembly and Reassembly 4 Troubleshooting 5 PCB Diagram 6 Wiring Diagram 7 Schematic Diagram 8 Reference Sheet Model AEX160EDEHA AEX140EDEHA AEX...

Страница 2: ...4 Troubleshooting 37 4 1Wired remote controller 37 4 2Troubleshooting by symptoms 40 4 2 1 Communication error after nishingTracking 40 4 2 2 EEPROM circuit failure 41 4 3 Hydro unit Mono 42 4 3 1 EE...

Страница 3: ...tage under over error E466 62 4 5 9 GAS leak error E554 63 4 5 10The other errors 64 4 5 11 In case of heating at the cooling mode or coolin g at the heating mode 65 4 5 12 Outdoor unit is not powered...

Страница 4: ...short circuit O Fasten the valve caps of service valves and charging valves of outdoor unit as much as possible using adjustable wrenches O Check the status of the components assembly after repair ser...

Страница 5: ...ation by an unqualified person may cause a water leakage electric shock or fire and so on O The electric work must be done by service agent or similarly qualified persons according to national wiring...

Страница 6: ...Brazing with the refrigerant still remaining in the product or pipe may cause poor result and generate harmful gas Furthermore pressure of the refrigerant may increase and cause damage to the leaking...

Страница 7: ...icity Permanent magnet strong magnetic rotor Double rotor compression cylinder Nd Fe B Neodium Iron Boron magnet SAMSUNG s double rotor compressor has the upper and lower rotors designed symmetrically...

Страница 8: ...an run the system after connecting water pipes only Q Integrated Heating Cooling system Plate Heat exchanger is a integral part in heating cooling system For user s convenience PHE is integrated into...

Страница 9: ...ating 1 A 5 8 4 9 4 2 Heating 2 A 6 9 5 8 5 0 Cooling 1 A 9 4 8 1 6 8 Cooling 2 A 8 5 7 4 6 4 Power Supply V Hz 3 380 415 50 3 380 415 50 3 380 415 50 COP EER 95 Heating 1 W W 4 30 4 50 4 70 Heating 2...

Страница 10: ...2 A 19 4 16 3 14 0 12 1 7 0 Cooling 1 A 26 4 22 6 19 1 12 7 8 8 Cooling 2 A 23 8 20 8 18 1 12 0 8 1 Power Supply V Hz 1 220 240 50 1 220 240 50 1 220 240 50 1 220 240 50 1 220 240 50 COP EER 95 Heati...

Страница 11: ...93 09348A DB93 09348A DB93 09348A 11 ELCB for Hydro unit SG 52NH 40A SG 52NH 40A SG 52NH 30A for DHW tank SG 52NH 20A SG 52NH 20A SG 52NH 20A 12 Magnet Contactor Spec CMC 25C 2P 3EA 25A CMC 25C 2P 3EA...

Страница 12: ...Outdoor Unit DB68 03207A 1 ASSY USER MANUAL DB68 03238A 1 Essential Offer Hydro unit ASSY INSTALLATION MANUAL DB68 03239A 1 Pattern sheet DB98 32365A 1 service valve DB96 13833A B 1 wall mounting bra...

Страница 13: ...ctronics Q Hand Tool sets 3 Disassembly and Reassembly Item Remark Screw Driver Adjustable wrench Screw Driver Nipper Electric Motion Driver L Wrench Torque Lench Latchet Lench RC160MHXGA_SM_E_34513A...

Страница 14: ...m it Use Screw Driver 2 Remove pressure sensor by adjustable wrench Use adjustable wrench 230kgf cm 3 Pull the manometer out 4 Pull the LED display up and out 3 1 Hydro Unit Q AEN160YD AEN080YD Be sur...

Страница 15: ...4 Samsung Electronics No Parts Procedure Remark 5 Remove the connector from the PCB board 6 Remove the upper case of the controller 7 Remove 5 screws Set a side the drain pan and hydro unit RC160MHXGA...

Страница 16: ...ark 3 Water Pump 1 Remove 4 screws Use Screw Driver 2 Remove the cabi control top 3 Remove the flow switch and connector 4 Remove a pipe from the backup Heater Use adjustable wrench 380kgf cm Use the...

Страница 17: ...lectronics No Parts Procedure Remark 5 After removing insulation material remove the Thermostat 6 Remove 2 screws Use Screw Driver 7 Remove 2 screws Use Screw Driver 8 Pull the water pump pipes up out...

Страница 18: ...on vessel and the backup heater by adjustable wrench Use adjustable wrench 150kgf cm Use the Torque Wrench when you assemble it 2 Remove 2 screws Use Screw Driver 3 After removing the nut Pull the bra...

Страница 19: ...mostats 3 Remove the Thermostat conector on the PCB of the Control box 4 Remove the pipe from the Backup Heater Use adjustable wrench 380kgf cm Use the Torque Wrench when you assemble it 5 Remove 6 sc...

Страница 20: ...s Procedure Remark 6 Control Box 1 Remove 4 Thermostats Set a side the terminal block and PBA case Use Screw Driver 2 Remove Conectors 3 Remove 3 screws Use Screw Driver 4 Pull the cabi control bottom...

Страница 21: ...ssembly 20 Samsung Electronics No Parts Procedure Remark 7 Backup Heater 1 Remove the Drain Hose 2 After removing 4 screws set a side the backup heater and the unit Use Screw Driver RC160MHXGA_SM_E_34...

Страница 22: ...e screws on the CABI FRONT RH Use type screw driver 2 CABI TOP 1 Unscrew and remove the nine screws on each side of the CABI TOP Use type screw driver 3 CABI INSTALL FRONT 1 Unscrew and remove the scr...

Страница 23: ...ssembly 22 Samsung Electronics No Parts Procedure Remark 4 GUARD COND 1 Pull the sensor from Guard Cond 2 Unscrew and remove the four screws on the GUARD COND Use type screw driver RC160MHXGA_SM_E_345...

Страница 24: ...msung Electronics 23 No Parts Procedure Remark 5 CABI BACK RH 1 Pull the sensor from the CABI BACK RH 2 Unscrew and remove the nine screws on each side the CABI BACK RH Use type screw driver RC160MHXG...

Страница 25: ...sembly and Reassembly 24 Samsung Electronics No Parts Procedure Remark 6 CABI INSTALL BACK 1 Unscrew and remove the 8 screws on the CABI FRONT LF Use type screw driver RC160MHXGA_SM_E_34513A 1 _1 3 in...

Страница 26: ...Disassembly and Reassembly Samsung Electronics 25 No Parts Procedure Remark RC160MHXGA_SM_E_34513A 1 _1 3 indd 25...

Страница 27: ...isassembly and Reassembly 26 Samsung Electronics No Parts Procedure Remark 7 FAN 1 Turn the two nuts as shown in the picture and remove them Use adjustable wrench RC160MHXGA_SM_E_34513A 1 _1 3 indd 26...

Страница 28: ...sung Electronics 27 No Parts Procedure Remark 8 MOTOR 1 Remove the fan 2 Unscrew and remove the eight motor screws Use type screw driver 3 Disconnect the motor wire from the Ass y Control Out RC160MHX...

Страница 29: ...ssembly and Reassembly 28 Samsung Electronics No Parts Procedure Remark 9 BRACKET MOTOR 1 Unscrew and remove the two screws on the BRACKET MOTOR Use type screw driver RC160MHXGA_SM_E_34513A 1 _1 3 ind...

Страница 30: ...tronics 29 No Parts Procedure Remark 10 CONTROL OUT 1 Disconnect the six connectors form the ASSY CONROL OUT 2 Unscrew and remove the three screws on the CONTROL OUT Use type screw driver 3 Separate t...

Страница 31: ...coolant first 2 Unscrew and remove the four screws on the SERVICE VALVE Use type screw driver 3 Separate the pipe from the Entrance Exit using a welder When removing the compressor heat exchanger and...

Страница 32: ...Remark 12 COMPRESSOR 1 Unscrew and remove the nut on the COVER TERMINAL Use adjustable wrench 2 Separate the compressor wire 3 Separate the COMPRESSOR FELT SOUND 4 As shown in the picture unscrew and...

Страница 33: ...ly and Reassembly 32 Samsung Electronics No Parts Procedure Remark 13 ASSY COND OUT 1 Unscrew remove the two screws on each side of the ASSY COND OUT Use type screw driver RC160MHXGA_SM_E_34513A 1 _1...

Страница 34: ...en 1 fixing screw of the Cover Control and detach the Cover Control 2 Loosen fixing screws and detach the Cabinet Upper 3 Loosen 1 screw fixed to assemble Control Box with Cabinet Side RH 4 Loosen 6 f...

Страница 35: ...sassembly and Reassembly 34 Samsung Electronics No Parts Procedure Remark 5 Loosen 2 screws fixed on the Guide Condenser 6 Loosen fixing screws of the Cabinet Front RC160MHXGA_SM_E_34513A 1 _1 3 indd...

Страница 36: ...d 2 Detach the Fan Propeller 3 Loosen 4 fixing screws to detach the Motor 4 Disconnect the wire between Ass y Control Out and Motor 5 Loosen 2 fixing screws and detach the Bracket Motor 3 Ass y Contro...

Страница 37: ...etach the Heat Exchanger Before you disassemble the pipes and Condenser be sure that there should be no refrigerant remained in the unit 1 Loosen xing screw CCW and detach the Heat Exchanger 5 Compres...

Страница 38: ...nication cable connection status Operation Off Communication error Communication error between indoor outdoor INVlMAIN MICOM 1 min Check MAIN MICOM Check INVERTER MICOM Communication error Outdoor tem...

Страница 39: ...PCB Operation Off Outdoor unit protection control error Inverter OTP error Check EEPROM DATA Check the normal operation of PCB Operation Off Outdoor unit protection control error AC ZERO CROSSING SIG...

Страница 40: ...COM2 terminal of the indoor unit Normal operation Wired remote controller error Communication error between the Master and Salve wired remote controllers Check the option switch for defining the Maste...

Страница 41: ...rm between the lines square wave with amplitude over 0 7V as shown in the following picture 0 7V 0 7V Good Bad Check the communication cable and replace the indoor unit PCB Remove the communication ca...

Страница 42: ...OM circuit failure Failure EEPROM component failure EEPROM circuit parts missing damaged soldering failure 4 2 2 EEPROM circuit failure No Yes Are the EEPROM circuit components in good conditions miss...

Страница 43: ...een EEPROM and MICOM Outdoor unit display Yes Are there any problems such as short or dewetting between EEPROM PIN If you restart after reentering model options and power reset does the error occur ag...

Страница 44: ...o The thermistor needs to be replaced No Re start after put the connetor in the PBA Yes Does wired remocon room thermistor connector come out of the PBA Is the resistance value Deviated from the temp...

Страница 45: ...start after put the connetor in the PBA Yes 1 How to check After putting out the thermistor from the PBA Measure its resistance value B W two terminal The thermistor needs to be replaced No Is the res...

Страница 46: ...o Re start after put the connetor in the PBA Yes 1 How to check After putting out the thermistor from the PBA Measure its resistance value B W two terminal The thermistor needs to be replaced No Is th...

Страница 47: ...laced Is it OPEN Yes Check water pump operates properly Does flow S W connector come out of the PBA Yes After putting out the connector F S from the PBA Measure its status is OPEN or SHORT Re start af...

Страница 48: ...etor in the PBA Yes 1 How to check Flow S W needs to be replaced Yes Is it short No Measure status of PBA is OPEN or SHORT Does flow S W connector come out of the PBA Yes After putting out the connect...

Страница 49: ...cted from the connector in PCB Restart the system after replacing the PCB Restart the system after connecting to the PCB connector Temperature sensor failure replace Remove the temperature sensor conn...

Страница 50: ...eform between the lines square wave with amplitude over 0 7V as shown in the following picture 0 7V 0 7V Good Bad Check the communication cable and replace the Control KIT unit PCB Remove the communic...

Страница 51: ...t decimal C 6 OLP sensor 6 Two digits One digit First decimal C 7 Cond sensor 7 Two digits One digit First decimal C 8 Current 8 Two digits One digit First decimal C 9 Fan RPM 9 Three digits Two digit...

Страница 52: ...eck OLP sensor Open Short E320 9 z MAIN Detection of Outdoor Freezing when Comp Stop Check Outdoor Cond E403 10 z MAIN Protection of Outdoor Overload when Comp Stop Check Comp when it start E404 11 z...

Страница 53: ...r Inverter PBA E474 30 z z MAIN INVERTER PFC Overload Error Check Outdoor Inverter PBA E484 31 z MAIN Input current sensor error E485 32 MAIN INVERTER IPM is over heated Check Outdoor Inverter PBA E50...

Страница 54: ...le and exchange the POUSPM kit PCB Remove the communication cable connecting the outdoor unit to indoor unit and measure the signal on LINE 2 of the outdoor unit with a scope Reconnect the cable conne...

Страница 55: ...BA and INVERTER PBA 2 Is the power cable connected correctly 2 Check procedure Does the communication error occur Yes No Normal operation Is the communication power cable connected properly between MA...

Страница 56: ...condition Check the sensor cable and connector Does the value of resistance satisfy the each temperature condition Yes No Exchange the temperature sensor Power on Yes Is the wire of sensor broken or i...

Страница 57: ...e of FAN cable housing normal Resistance of FAN cable housing at the normal temperature 10 C 30 C wire pin number Resistance Remark RED BLACK 1 3 over 1M 300V motor power WHITE BLACK 4 3 1K 2K 15V con...

Страница 58: ...No No Cont Exchange INVERTER PCB Exchange the FAN motor Is the Pin voltage 6 3 of CN90 and 91 changed high 4 5V and low 0 1V in case of making manual rotation slowly Is the Pin voltage 7 3 of CN90 an...

Страница 59: ...resistance between each phase for compressor smaller than 2 Yes No 3 Is the resistance normal between each phase for compressor Exchange the compressor Is the value of resistance mega between compress...

Страница 60: ...obstacle Yes No 3 Does the fan of outdoor unit work normally Does the compressor work normal Yes No Are the service valves fully opened Yes No Open the service valves Primary current trip error E462...

Страница 61: ...e connection of compressor correctly Are the service valves fully opened Yes No Open the service valves 4 Is there any obstacle around indoor and outdoor unit Is the indoor unit installed well accordi...

Страница 62: ...n and measured value of temperature sensor normal reposition the sensor reposition the sensor cont Is the value of resistance mega between compressor and outdoor unit body Yes No Exchange the compress...

Страница 63: ...rrectly 2 Check procedure Is the power cable connected correctly Yes No Connect the power cable Yes No Check whether a fuse has blown Yes No Exchange the fuse Is the reactor connected correctly Check...

Страница 64: ...o Normal operation Yes No Are the service valves fully opened Yes No Open the service valves Is the evaporator sensor of indoor unit connected correctly Yes No Connect the sensor s connector Yes No Ch...

Страница 65: ...or air temperature is over 35 C Check the outdoor temperature E441 Cooling operation is not available since the outdoor air temperature is lower than 15 C E465 Compressor over load error Compressor is...

Страница 66: ...resistance value of 4 WAY valve coil Go to the next page 4 WAY valve main body error Attach the sensor correctly Over shortage of the refrigerant Connect the connecter correctly 4 WAY valve coil error...

Страница 67: ...f DC300V apply to the connector of outdoor fan during the operation of outdoor unit The over shortage of refrigerant t Capacity Load estimation error Connect the connector Outdoor fan error Check the...

Страница 68: ...nit power supply N R N S N T 220Vac Yes Check connection of the outdoor unit terminal block No Is the outdoor unit power voltage L N 220Vac Yes Check the connection wires and connectors of the indoor...

Страница 69: ...39 MAIN PCB CN31 INVERTER PCB Is the FUSE on INVERTER PCB blown Check and correct the wire or socket connection Check Fuses listed blow 3 FUSES in EMI PCB 1 FUSE in MAIN PCB No Is there miss connectio...

Страница 70: ...F1 F2 Communication signal F2 V1 DC12V V2 GND F3 Communication signal F3 F4 Communication signal F4 1 WATER TANK sensor 2 GND 1 HEATER OUT sensor 2 GND 3 6 Not used TB A POWER IN HEATER TB B TERMINAL...

Страница 71: ...70 Samsung Electronics 5 2 Outdoor Unit MAIN PCB 1 5 6 2 3 4 15 7 16 9 11 13 8 10 12 14 This Document can not be used without Samsung s authorization RC160MHXGA_SM_E_34513A 1 _5 8 indd 70...

Страница 72: ...l 5 DC 12V 1 4 Motor signal 5 DC 12V G 1 TXD 2 RXD 3 GND 4 DC 5V 5 DC 12V 6 INV SMPS signal 1 Temp signal 2 GND 1 High Pressure temp signal 3 GND 4 DC 5V 1 DC 12V 2 GND 1 COM1 2 COM2 1 DC 12V 2 GND 3...

Страница 73: ...eer debugging 1 DC 360V 2 N C 3 GND 4 DC 15V 5 FAN RPM 6 FAN RPM feedback 1 DC 360V 2 N C 3 GND 4 DC 15V 5 FAN RPM 6 FAN RPM feedback 1 COMP U phase RED 2 COMP V phase BLU 3 COMP U phase YEL 1 2 DCL R...

Страница 74: ...onics 73 R AC 380 400V WHT S AC 380 400V BRN T AC 380 400V BLK 1 3 AC 220 240V RST AC POWER 3phase CN100 AC POWER 2 1 EMI PCB This Document can not be used without Samsung s authorization RC160MHXGA_S...

Страница 75: ...onics Heater PCB 1 2 AC POWER INPUT 1ACPOWERLINE LIVE 2ACPOWERLINE NEUTRAL AC POWER OUTPUT 1ACPOWERLINE LIVE 2ACPOWERLINE NEUTRAL This Document can not be used without Samsung s authorization RC160MHX...

Страница 76: ...RE 12V 200mW 5000mA 1FormA 10ms 5ms 1 PC SNA FUSE02 3601 000263 FUSE CARTRIDGE 250V 3 15A TIME LAG GLASS 5x20mm 1 PC SA F101 3602 001012 FUSE BLOCK 500V 100MOhm 1 PC SNA IC83 3704 001601 SOCKET IC 8P...

Страница 77: ...SNA F102 3601 001308 FUSE 250V 1 6A TIME LAG PLASTIC 8 4x7 6mm 1 PC SNA DB93 11369C ASSY PCB SMD EHS Outdoor Main 14KW REMKO 1 PC SNA SOLDER CREAM 0202 001459 SOLDER CREAM S3X58 M405 D20 38um 96 5Sn 3...

Страница 78: ...P 100ohm 5 1 10W TP 1608 1 PC SNA R203 2007 000076 R CHIP 330ohm 5 1 10W TP 1608 1 PC SNA R309 2007 000076 R CHIP 330ohm 5 1 10W TP 1608 1 PC SNA R310 2007 000076 R CHIP 330ohm 5 1 10W TP 1608 1 PC SN...

Страница 79: ...007 000614 R CHIP 24Kohm 1 1 10W TP 1608 1 PC SNA R418 2007 000614 R CHIP 24Kohm 1 1 10W TP 1608 1 PC SNA R117 2007 000683 R CHIP 3 3Kohm 1 1 10W TP 1608 1 PC SNA R114 2007 000701 R CHIP 3 6Kohm 1 1 1...

Страница 80: ...X7R TP 1608 1 PC SNA C311 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 PC SNA C312 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 PC SNA C403 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1...

Страница 81: ...RADIAL 4 7uH 10 6 5x7 5mm 1 PC SNA RY12 3501 001163 RELAY MINIATURE 12V 200mW 5000mA 1FormA 10ms 5ms 1 PC SNA RY13 3501 001163 RELAY MINIATURE 12V 200mW 5000mA 1FormA 10ms 5ms 1 PC SNA RY11 3501 00126...

Страница 82: ...uF 20 35V WT TP 8x11 5mm 5 1 PC SNA C117 2401 003585 C AL 220uF 20 35V WT TP 8x11 5mm 5 1 PC SNA C120 2401 003585 C AL 220uF 20 35V WT TP 8x11 5mm 5 1 PC SNA C121 2401 003585 C AL 220uF 20 35V WT TP 8...

Страница 83: ...PHOTO COUPLER TR 100 600 200mW SOP 4 TP 1 PC SNA PC400 0604 001002 PHOTO COUPLER TR 100 600 200mW SOP 4 TP 1 PC SNA PC401 0604 001002 PHOTO COUPLER TR 100 600 200mW SOP 4 TP 1 PC SNA PC402 0604 00100...

Страница 84: ...CHIP 3 3Kohm 5 1 10W TP 1608 1 PC SNA R111 2007 000082 R CHIP 3 3Kohm 5 1 10W TP 1608 1 PC SNA R600 2007 000082 R CHIP 3 3Kohm 5 1 10W TP 1608 1 PC SNA R300 2007 000084 R CHIP 4 7Kohm 5 1 10W TP 1608...

Страница 85: ...5 R CHIP 100Kohm 5 1 4W TP 3216 1 PC SNA R909 2007 000285 R CHIP 100Kohm 5 1 4W TP 3216 1 PC SNA R802 2007 000308 R CHIP 10ohm 5 1 8W TP 2012 1 PC SNA R804 2007 000308 R CHIP 10ohm 5 1 8W TP 2012 1 PC...

Страница 86: ...1 PC SNA C504 2203 000257 C CER CHIP 10nF 10 50V X7R TP 1608 1 PC SNA C505 2203 000257 C CER CHIP 10nF 10 50V X7R TP 1608 1 PC SNA C814 2203 000257 C CER CHIP 10nF 10 50V X7R TP 1608 1 PC SNA C301 220...

Страница 87: ...4 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 PC SNA C800 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 PC SNA C802 2203 005249 C CER CHIP 100nF 10 50V X7R TP 1608 1 PC SNA C804 2203 005249...

Страница 88: ...09 2301 001285 C FILM LEAD PPF 680nF 10 275V BK 31x11x21mm 1 PC SNA C10 2301 001285 C FILM LEAD PPF 680nF 10 275V BK 31x11x21mm 1 PC SNA C01 2301 001853 C FILM LEAD 2200nF 10 275V BK 18X28X31 1 PC SNA...

Страница 89: ...FUSE L 3602 001012 FUSE BLOCK 500V 100MOhm FUSE L 3601 000416 250V 1A FAST ACTING GLASS 5 2x20mm FUSE N 3602 001012 FUSE BLOCK 500V 100MOhm FUSE N 3601 000416 250V 1A FAST ACTING GLASS 5 2x20mm JP01...

Страница 90: ...Samsung Electronics 89 6 Wiring Diagram 6 1 Hydro unit Sensor part This Document can not be used without Samsung s authorization RC160MHXGA_SM_E_34513A 1 _5 8 indd 89...

Страница 91: ...90 Samsung Electronics 6 2 Outdoor Unit 3Phase 2FAN Model Diagram This Document can not be used without Samsung s authorization RC160MHXGA_SM_E_34513A 1 _5 8 indd 90...

Страница 92: ...Wiring Diagram Samsung Electronics 91 1Phase 2FAN Model This Document can not be used without Samsung s authorization RC160MHXGA_SM_E_34513A 1 _5 8 indd 91...

Страница 93: ...2SC2412K 0 2W 2 1 3 C B E EXT_CTRL_1_HEATING EXT_CTRL_1_COOLING EXT_CTRL_2_HEATING R93 J 680 1 10W 2 1 150mA 75V 1N4148WS D180 2 1 EXT_CTRL_2_COOLING R94 0 1W J 1K 2 1 Neutral_ SOLAR_PUMP_OP VCC VCC...

Страница 94: ...96 03AV CN01 3 2 1 V 0 5 2 A 1 F FUSE L 2 1 FUSE N V 0 5 2 A 1 F 2 1 560V INR14D561K VA01 2 1 560V INR14D561K VA03 2 1 VA02 2 560V INR14D561K 1 JUMPER JP01 2 1 JUMP wire_hole_2 4 TE1 1 OPTION SELECT P...

Страница 95: ...tage A A 115V 60hz 1 B B 220V 60Hz 1 C C 208 230V 60Hz D D 200 220V 50Hz E E 220 240V 50Hz F F 208 230V 60Hz 3 G G 380 415V 50Hz 3 H H 380V 60Hz 3 J J 460V 60Hz 3 K K 220 240V 50 60Hz 1 M M 127V 50Hz...

Страница 96: ...T S 3 For PHE in temp T S 4 For PHE out temp T S 5 For discharge temp T S 6 For cond temp T S 7 For ambient temp sensor S V Service valve inch Accum Accumulator PHE T S 3 T S 4 S V S V 4WAY v v T S 5...

Страница 97: ...and or domestic law Samsung Electronics Co Ltd Aug 2012 Printed in Korea Code No DB68 03317A 1 GSPN Global Service Partner Network Area Web Site Eurpoe CIS Mideast Africa gspn1 samsungcsportal com As...