![Samsung AEGIS WF-M592NMH Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/samsung/aegis-wf-m592nmh/aegis-wf-m592nmh_service-manual_358435023.webp)
24 _ Removal and Reassembly
Part
Figure
Description
DRAIN PUMP
1. Insert the (-) screwdriver into the upper part
of the Filter Cover and push it downwards
to release the catch.
2. Remove the remaining water through the
drainage hose.
Place a bowl under the drainage hose,
or the remaining water may flow out.
3. Separate the Drain Filter by turning it
counterclockwise.
Since the remaining water may flow
out, place a bowl underneath it when
separating the filter..
4. Remove the 1 screws holding the Drain
Pump.
5. Remove the remaining water through the
drainage hose.
WF-M592NMH-YLP.indb 24
2010-2-22 13:29:52