16 _ Removal and Reassembly
3-2. STANDARD DISASSEMBLY DRAWINGS
► This is a standard disassembly diagram and may differ from the actual product.
Use this material as a reference when disassembling and reassembling the product.
Part
Figure
Description
ASSY COVER TOP
1. Remove the two screws holding the Top
Cover at the back of the unit.
2. Remove the top-cover by lifting it up after
pulling it back about 15mm.
3. Then, the Water (Pressure) Sensor, Noise
Filter and Water Valve can be replaced.
Water valve
Noise filter
Sensor pressure