Field setting mode
Field Setting Value (FSV) Table
NOTE
•
Reset the power after changing the Field Setting Value.
Code 10∗∗ : Upper and lower temperature limits of each operation mode of wired remote controller
Heating(Water Out, Room), Cooling(Water Out, Room), DHW(Tank)
Code 20∗∗ : Water law design and external room thermostat Heating(2 WL’s for floor & FCU),
Cooling(2 WL’s for floor & FCU), WL & Thermostat types
Field Setting Value
Main Menu &
Code
Sub Menu Function
Description Sub Code Default
Min
Max
Step
Unit
Remote
Controller
Setting Range
Code 10∗∗
Water Out Temp for Cooling
Max
∗∗11
25
18
25
1
˚C
Min
∗∗12
16
5
18
1
˚C
Room Temp for Cooling
Max
∗∗21
30
28
30
1
˚C
Min
∗∗22
18
18
28
1
˚C
Water Out Temp for Heating
Max
∗∗31
55
37
55
1
˚C
Min
∗∗32
25
15
37
1
˚C
Room Temp for heating
Max
∗∗41
30
18
30
1
˚C
Min
∗∗42
16
16
18
1
˚C
DHW Tank Temp
Max
∗∗51
50
50
70
1
˚C
Min
∗∗52
40
30
40
1
˚C
Water Law
Code 20∗∗
Outdoor Temp for Water Law
(Heating)
Point
1
∗∗11
-10
-20
5
1
˚C
Point
2
∗∗12
15
10
20
1
˚C
Water Out Temp for WL1
Heating (WL1-Floor)
Point
1
∗∗21
40
17
55
1
˚C
Point
2
∗∗22
25
17
55
1
˚C
Water Out Temp for WL2
Heating (WL2-Fan Coil Unit)
Point
1
∗∗31
50
17
55
1
˚C
Point
2
∗∗32
35
17
55
1
˚C
Heating Water Law for Auto
Mode
WL Type
∗∗41
1(WL1)
1
2
-
-
Outdoor Temp for Water Law (Cooling) Point
1
∗∗51
30
25
35
1
˚C
Point
2
∗∗52
40
35
45
1
˚C
Water Out Temp for WL1
Cooling (WL1-Floor)
Point
1
∗∗61
25
5
25
1
˚C
Point
2
∗∗62
18
5
25
1
˚C
Water Out Temp for WL2
Cooling (WL2-Fan Coil Unit)
Point
1
∗∗71
18
5
25
1
˚C
Point
2
∗∗72
5
5
25
1
˚C
Cooling Water Law for Auto Mode WL Type
∗∗81
1(WL1)
1
2
-
-
External Thermostat
Application
#1 (Floor)
∗∗91
0(No)
0
4
1
-
#2 (FCU)
∗∗92
0(No)
0
4
1
-