Disassembly and Reassembly
3-9
No.
Parts
Procedure
Remark
4
Drain Pump & Hose
2) Remove the 2 screws and separate the Drain
Hose that is on the side lower part of Indoor
Unit (Use +Screw Driver)
5
Fan & Motor
1) Remove the hex nut which is fixed to top of
Fan and separate the Fan from the Motor.
(Use Monkey Spanner)
2) Remove the 3 hex nuts which is fixed to Motor
and separate the Motor from the Indoor Unit.
(Use Monkey Spanner)
6
Temperature Sensor
1) Remove the 6 screws which is fixed to
Evaporator and separate the Partition.
2) Separates the Temperature Sensor which is
fixed to Evaporator Pipe with the fixing clip
together by the hand.