8-4
8-2 Refrigerating Cycle Diagram
■
CONDENSER
High temperature and high pressure gas state coolant discharged from the compressor is converted to a liquid state as it is cooled down
by the heat emission in the outdoor condenser unit, and sent to the evaporator.
■
COMPRESSOR
Low temperature and low pressure coolant is compressed and sent to the cycling system
■
EVAPORATOR
Liquid coolant sucked in through the capillary tubes cools down the room by absorbing the surrounding heat as it evaporates (converting
from liquid to gas). (Absorbing heat required for evaporation)
■
SERVICE VALVE
You can open the valve by turning the need valve counterclockwise using hex wrench, and it is used for vacuum, gas purging, coolant
injection, coolant purging, and indoor-outdoor unit connection.
■
ACCUMULATOR
Accumulator prevents the flow of liquid-state coolant into the compressor. (Liquid-state coolant flowing into the compressor will overload
the compressor.)
Indoor Unit
Outdoor Unit
Heat exchanger
Evaporator
Liquid pipe
Gas pipe
3-way valve
3-way valve
Electronic expansion valve
Compressor
4-way valve
Cooling
Heating
Leak check points
Aux accumulator
Fan
Heat exchanger
Evaporator
Fan
Содержание AC071MN4PKH
Страница 12: ...ProductSpecifications 2 9 2 3 4 Filter specifications Item Description CodeNo Remark FILTER AIR DB63 03764A ...
Страница 101: ...PCBDiagramandPartsList 5 4 5 1 3 Outdoor PCB Main PCB AC090 100 120 140MXAD H 1 2 3 4 5 6 8 9 10 11 12 ...
Страница 103: ...PCBDiagramandPartsList 5 6 Outdoor Unit PCB cont PF 4 INVERTER PCB SINGLE PHASE I AC090 100MXADKH 4 1 2 8 3 7 6 5 ...
Страница 105: ...PCBDiagramandPartsList 5 8 Outdoor Unit PCB cont PF 6 1 INVERTER PCB 3 PHASE I AC100MXADNH 1 2 8 4 6 5 3 7 ...
Страница 114: ...6 3 WiringDiagram ThisDocumentcannotbeusedwithoutSamsung sauthorization 3 phase PF 6 PF 6 1 Schematic Diagram ...