38
Testing operations
7 . DIP switch option
ON
1 2 3 4
ON
1 2 3 4
SW507
SW508
f
f
DIP switch(SW507) option
On (default)
Off
Switch 1
Auto address
Manual address
Switch 2
Disable snow prevention control
Enable snow prevention control
Switch 3
Silence Mode option
Switch 4
❋
❋
When snow prevention mode is in use, eco mode(standby mode)will not be functional.
❋
❋
When DPM installation is applied, the time for auto addressing will take 1~2minutes.
During the addressing,
and
will be repeatedly displayed in order for 2 indoor unit connection,
,
and
for 3 indoor unit connection,
,
,
and
for 4 indoor unit connection .
When addressing is completed,
,
,
,
and
will be repeatedly displayed in order for 2 indoor unit
connection,
,
,
,
,
and
for 3 indoor unit connection,
,
,
,
,
,
and
for 4 indoor unit connection .
f
f
DIP switch(SW508) option
On(default)
Off
Switch 1
Auto Silence Mode
Manual Silence Mode
Switch 2
-
-
Switch 3
-
-
Switch 4
-
-
8 . Silence Mode DIP switch option
(AC
TTT
HCAPKH, AC
TTT
HCAPNH, AC
TTT
HCADKH, AC
TTT
HCADNH, AC
TTT
JXADEH, AC
TTT
JXADGH,
AC100JXADEH1)
f
f
DIP switch(SW507) option
Switch 3
Switch 4
Operation
On
On
Disable Silence mode
On
Off
Silence mode 1st step
Off
On
Silence mode 2nd step
Off
Off
Silence mode 3rd step
CAC GD-EU_IM_32793A-23_EN.indd 38
2016-05-25 오후 7:08:49