Power Cable Specifications
f
f
The power cable is not supplied with air conditioner .
- Select the power supply cable in accordance with relevant local and national regulations .
- Wire size must comply with the applicable local and national code .
- Specifications for local wiring power cord and branch wiring are in compliance with local cord .
Single Phase
Type of
outdoor
unit
Model
Outdoor Units
Input Current [A]
Power Supply
Outdoor Unit
Indoor Unit
Rated
Voltage Range
Outdoor (Down_Amp)
Indoor
Total
MCA
MFA
Hz
Volts
Min.
Max.
Cooling
Heating
A
AC090FCADEH AC090FB4DEH
50
220-240
198
264
24
24
0 .7
24 .7
24 .7
30 .0
AC090FCAPEH AC090FB4PEH
50
220-240
198
264
24
24
1 .0
25 .0
25 .0
30 .0
AC090FCASEH AC090FBMSEH
50
220-240
198
264
22
22
1 .5
23 .5
23 .5
27 .5
AC100FCADEH AC100FB4DEH
50
220-240
198
264
24
24
0 .7
24 .7
24 .7
30 .0
AC100FCASEH AC100FBMSEH
50
220-240
198
264
22
22
1 .5
25 .0
25 .0
30 .0
RC090PHXEA
NS0904PXEA
50
220-240
198
264
24
24
1 .0
25 .0
25 .0
30 .0
RC090SHXEA
NS090SSXEA
50
220-240
198
264
22
22
1 .5
23 .5
23 .5
27 .5
RC100DHXEA
NS1004DXEA
50
220-240
198
264
24
24
0 .7
24 .7
24 .7
30 .0
NS100SDXEA
50
220-240
198
264
24
24
1 .5
25 .5
25 .5
30 .0
RC100SHXEA
NS100SSXEA
50
220-240
198
264
22
22
1 .5
23 .5
23 .5
27 .5
AC071HCAPKH AC071HBMPKH 50/60 220-240
198
264
24
24
2 .7
26 .7
26 .7
30 .0
AC120HCADKH AC120HBMDKH 50/60 220-240
198
264
24
24
2 .7
26 .7
26 .7
30 .0
AC100HCADKH AC100HBMDKH 50/60 220-240
198
264
24
24
2 .7
26 .7
26 .7
30 .0
AC090HCADKH AC090HBMDKH 50/60 220-240
198
264
24
24
2 .7
26 .7
26 .7
30 .0
AC100JXADEH AC100JNCDEH
50
220-240
198
264
22
22
2 .7
24 .7
24 .7
30 .0
AC100JXADEH1 AC100JNCDEH1
AC120JXADEH AC120JNCDEH
50
220-240
198
264
24
24
2 .7
26 .7
26 .7
30 .0
B
AC100FCAPEH AC100FB4PEH
50
220-240
198
264
24
24
1 .0
25 .0
25 .0
30 .0
RC100PHXEA
NS1004PXEA
50
220-240
198
264
24
24
1 .0
25 .0
25 .0
30 .0
RC100DHXEH
NS100HHXEH
50
220-240
198
264
24
24
2 .0
26 .0
26 .0
30 .0
RC100DHXEG
NS100HHXEG
50
220-240
198
264
24
24
2 .0
26 .0
26 .0
30 .0
RC125DHXEB
NS1254DXEA
50
220-240
198
264
24
24
1 .0
25 .0
25 .0
30 .0
NS125SDXEA
50
220-240
198
264
24
24
2 .0
26 .0
26 .0
30 .0
RC125PHXEA
NS1254PXEA
50
220-240
198
264
24
24
1 .0
25 .0
25 .0
30 .0
RC125DHXEH
NS125HHXEH
50
220-240
198
264
24
24
2 .8
26 .8
26 .8
30 .0
RC125DHXEG
NS125HHXEG
50
220-240
198
264
24
24
2 .8
26 .8
26 .8
30 .0
RC140DHXEB
NS1404DXEA
50
220-240
198
264
24
24
1 .0
25 .0
25 .0
30 .0
NS140SDXEA
50
220-240
198
264
24
24
2 .0
26 .0
26 .0
30 .0
AC090HCAPKH AC090HBMPKH 50/60 220-240
198
264
24
24
2 .7
26 .7
26 .7
30 .0
AC140HCADKH AC140HBMDKH 50/60 220-240
198
264
24
24
2 .7
26 .7
26 .7
30 .0
AC140JXADEH AC140JNCDEH
50
220-240
198
264
24
24
2 .7
26 .7
26 .7
30 .0
C
AC100FCAFEH
AC100FB4FEH
50
220-240
198
264
24
24
1 .0
25 .0
25 .0
30 .0
RC140PHXEA
NS1404PXEA
50
220-240
198
264
32
32
1 .0
33 .0
33 .0
40 .0
RC100ZHXEA
NS1004ZXEA
50
220-240
198
264
24
24
1 .0
25 .0
25 .0
30 .0
RC140DHXEH
NS140HHXEH
50
220-240
198
264
32
32
3 .5
35 .5
35 .5
40 .0
RC140DHXEG
NS140HHXEG
50
220-240
198
264
32
32
3 .5
35 .5
35 .5
40 .0
RC155DHXEH
NS155HHXEH
50
220-240
198
264
32
32
4 .6
36 .6
36 .6
40 .3
RC155DHXEG
NS155HHXEG
50
220-240
198
264
32
32
4 .6
36 .6
36 .6
40 .3
AC140HCAPKH AC140HBMPKH 50/60 220-240
198
264
32
32
2 .7
34 .7
34 .7
40 .0
AC120HCAPKH AC120HBMPKH 50/60 220-240
198
264
32
32
2 .7
34 .7
34 .7
40 .0
AC100HCAPKH AC100HBMPKH 50/60 220-240
198
264
32
32
2 .7
34 .7
34 .7
40 .0
Connecting the cable
CAC GD-EU_IM_32793A-23_EN.indd 12
2016-05-25 오후 7:08:25