16
English
Installation Procedure
Installation Pr
oc
edur
e
Step 12 Connecting the power and
communication cables
Bushing bracket installation
When using conduit, the bushing bracket must be
installed as shown in the picture to attach the conduit.
1
2
3
5
4
CAUTION
• Always remember to connect the refrigerant pipes
before performing the electric connections.
When disconnecting the system, always disconnect
the electric cables before disconnecting the
refrigerant pipes.
CAUTION
• Always remember to connect the air conditioner to
the grounding system before performing the electric
connections. Use a crimp ring terminal at the end of
each wire.
The indoor unit is powered through the outdoor unit by
means of a H05RN-F connection cable (or a more power
model), with insulation in synthetic rubber and a jacket
in polychloroprene (neoprene), in accordance with the
re
α
uirements specified in the standard EN 60335-2-40.
1
Remove the screw on the electrical component box
and remove the cover plate.
2
Route the connection cord through the side of the
indoor unit and connect the cable to the terminals
refer to the figure below.
3
Route the other end of the cable to the outdoor unit.
4
Reassemble the electrical component box cover,
carefully tightening the screw.
L
1(L) 2(N)
F1
F2
L
N
F2
N
F1
Indoor power supply
Power supply
Max/
Min(V)
Indoor power cable
208 to 230V,
60 Hz
±10%
0.0012 inch
ࠏॱ
(0.75mm
2
ॱ
),
3 wires
Communication cable
0.0012 inch
ࠏॱ
(0.75mm
2
ॱ
), 2 wires
0.35(9.0)
0.
54
(
13
.8
)
0.30(7.5)
0.50(12.6)
0.39(9.8)
push
Click
1 conduit tube
2 conduit tubes
Communication
cable
Indoor Power
cable
Main power
cable
Cable clamp
Indoor Unit
Outdoor Unit
Cable
Tie
AC power: M4 screw
Communication: M3.5 screw
Unit:inch(mm)