21
English
No
Hotel TV Function
Description
Category
initial value
11
External Source
USB Media
Mode
Default
When USB is connected to the TV,
y
Default : Popup window appears.
y
Automatic : Enters the USB contents menu
automatically.
y
Disable : Neither the pop-up window or nor the
menu appears.
External Source
Banner
ON
Users can set External Source Banner to On or Off.
On : When TV power On or Mode changed, TV will
display the external source banner.
Off : When TV power On or Mode changed, TV will not
display the external source banner.
Auto Source
OFF
On : When an external source is connected to the TV,
the TV will auto ident and switch the input source.
PC : Auto Ident PC Input only.
Off : Auto Source is Off.
Return
Source
Power On Src
Set the return source after closing .
12
Bathroom Speaker
Sub AMP mode 2
Determines the Sub AMP operation mode.
- 0: Turns the Sub AMP function off (PWM off).
- 1: Determines the Sub volume according to the main
volume control.
That is, the sub volume is determined according to the
Power On Volume, the Min Volume, and the Max
- 2: Determines the volume according to the bathroom
control panel setting.
Sub AMP
volume
6
Sub AMP Volume level at power on initial condition.
13
Eco Solution
Energy Saving
Off
This feature adjusts the brightness of the TV in order to
reduce power consumption.
- Off: Turns off the energy saving function.
- Low: Sets the TV to low energy saving mode.
- Medium: Sets the TV to medium energy saving mode.
- High: Sets the TV to high energy saving mode.
14
Logo/Message
Welcome
message
OFF
Display Welcome Message.
Edit Welcome
Message
Edit Welcome Message.
Hospitality
Logo
OFF
Use can set the logo display Off or the type of logo file
(BMP/AVI).
Hospitality
Logo DL
-
Download the logo file from USB toTV.
Logo Display
Time
5 Seconds
Set the logo display time (3/5/7 Seconds).
15
Cloning
Clone TV to
USB
-
USB Clone: TV
→
USB
Clone USB
to TV
-
USB Clone: USB
→
TV
Setting Auto
Initialize
OFF
When Setting Auto Initialize is set to On, and the power
is turned off and on or the Master Power is turned off
and on, the data is restored to the cloned values.
If there is no cloned value, even when the Setting Auto
Initialize is set to On, it will be ignored and the operation
will be the same as that whenSetting Auto Initialize is
set to Off
[Hotel-590_690_790]BN68-04282R-Eng.indd 21
2012-07-26 오후 2:46:49