background image

4

ZM Series Layout - Rear Panel

1-   25V, 70V and 100V (output connector) 

- Ten-

contact Euroblock connector for connecting the 25V, 

70V and 100V constant voltage outputs.

2 -   LO-Z (output connector)

 - Two-contact Euroblock 

connector for connecting the 4-Ohm speaker output.

3 -   AMP IN and PRE-AMP OUT (connectors) 

– These 

1/4-inch phone jacks are used to connect an external 

effect processor.

4 -   MOH VOLUME (control knob)

 –This control knob 

allows you to adjust the level of the Music on Hold 

sound source.

5 -   MOH (selection switch)

 – The slide switch is used 

to chose the Music on Hold sound source from the 

output of the internal mixer or an external sound 

source (like a CD or MP3 player). 

6 -   CHIME VOLUME - (control knob) 

– The control knob 

is used to adjust the level of the Chime tone.

7 -   GAIN (control knobs)

 – The trim knobs are used to 

set the input sensitivity for each input channel.

8 -   PRIORITY MIC (switch)

 – When set to on, this slide 

switch configures mic channels 1 and/or 2 to mute 

the other input channels when a signal is present on 

the connected microphones. 

9 -   PHANTOM POWER (switch)

 – Used this slide switch 

to activate the phantom power on mic channels 1 

and/or 2. 

10 -  MIC/LINE INPUTS (connectors)

 – Channels 1 and 

2 employ combination connectors with XLR and 

1/4-inch inputs, which can accept either mic or line 

signals. 

MIC

ON

OFF

ON

OFF

PRIORITY

-6

-50

PHANTOM

GAIN

MIC

ON

OFF

ON

OFF

PRIORITY

-6

-50

PHANTOM

GAIN

MIC

-6

-50

GAIN

MIC

-6

-50

GAIN

MIC

GAIN

-6/+14

-50/-30

GAIN

-6/+14

-50/-30

GAIN

LINE/
EXT. MOH

LINE

REMOTE MIC

MIN

G

C

H

G

C

H

G

C

SW

H

LINK OUT

PRE-AMP
OUT

LINK IN

AMP IN

MAX

VOLUME

VOLUME

MIN

MAX

MIN

MAX

INT.

EXT.

MUSIC ON HOLD

CHIME

TELE-PAGING

MIC

1

2

3

4

7

6

5

9

8

11

10

12

13

14

15

16

17

18

19

OUTPUT

COM

Constant Voltage 100V/70V/25V

Lo-Z

FUSE T2AL/250V

FM

75

300

125 WATT ZONE AMPLIFIER

ZM125

SAMSON

WARNING

DO NOT EXPOSE 

THIS EQUIPMENT 

TO RAIN OR 

MOISTURE

CAUTION

FOR CONTINUED 

PROTECTION AGAINST 

RISK OF FIRE, REPLACE 

ONLY SAME TYPE FUSE

AVIS

RISQUE DE CHOC 

ELECTRONIQUE NE 

PAS OUVRIR

ATTENTION

UTILISER UN FUSIBLE 

DE RECHANGE MEME 

TYPE

115Vac/230Vac

50Hz/60Hz, 167W

115 V

230 V

11 -  MIC INPUTS (connectors)

 – Channels 3 and 4 

are microphone level inputs on standard XLR 

connectors.

12 - MIC/LINE INPUTS (connectors)

 – Input channels 5 

and 6 feature 1/4-inch and RCA connectors for mic 

or line level input signals.

13 - REMOTE MIC input connector

 – Connect the 

paging microphone to this four-contact Euroblock 

connector.

14 - REMOTE MIC GAIN (control knob)

 – This trim 

control is used to set the input sensitivity for the 

remote microphone input.

15 - TELE PAGING (connector) 

– This three-contact 

Euroblock connector is used to connect the ZM 

series to a business telecom system so that pages 

can be made from any handset. 

1

6 -  MOH OUTPUT (connector)

 - This three-contact 

Euroblock connector is used to attach an external 

sound source for the Music on Hold system.

17 -  LINK IN and LINK OUT (connectors)

 - Use these 

connectors to expand your system by adding a 

second ZM series mixer/amplifier.

18 - VOLTAGE SELECTION (switch) 

 - Used to select the 

operation voltage for either 115 or 230 Volts. Be 

sure to check the correct operating voltage for your 

particular country.

19 - AC INLET

 – Connect the supplied IEC power cable 

here.

Содержание ZM125

Страница 1: ...AX MIN MAX MIN MAX MIN MAX ALL ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 12dB 0 dB 12dB 12 0 12 125Hz 250Hz 500Hz 1kHz 8kHz 3 0 4 10 20 ON OFF MIN MAX 2kHz 4kHz SAMSON MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX...

Страница 2: ...NG TYPE PLUG POLARIZED PLUG HAS TWO BLADES WITH ONE WIDER THAN THE OTHER GROUNDING TYPE PLUG HAS TWO BLADES AND A THIRD GROUNDING PRONG 4HE WIDE BLADE OR THE THIRD PRONG ARE PROVIDED FOR YOUR SAFETY F...

Страница 3: ...or objects have fallen into the unit the unit has been exposed to rain or moisture does not operate normally or has been dropped PRECAUCION Para reducir el riesgo de incendios o descargas no permita q...

Страница 4: ...samsontech com Table of Contents Introduction 1 ZM Series Features 2 ZM Series Layout Front Panel 3 ZM Series Layout Rear Panel 4 Designing an Installation Plan 5 Operating The ZM Series 8 Operating...

Страница 5: ...he ZM75 and ZM125 can be table top or mounted in a standard 19 inch equipment rack using the included rack mount ears The sleek black finish matches just about any d cor plus the steel chassis adds to...

Страница 6: ...ce or pre recorded announcement to your telephone system A convenient telephone paging input on a Euroblock terminal allows you to interface your PBX system for handset paging 12dB 0 dB 12dB 12 0 12 1...

Страница 7: ...6 LEVEL control knob The six control knobs are used to set the individual level of the input sources 7 MASTER control knob This control knob adjusts the overall system volume 12dB 0 dB 12dB 12 0 12 1...

Страница 8: ...G C H G C H G C SW H LINK OUT PRE AMP OUT LINK IN AMP IN MAX VOLUME VOLUME MIN MAX MIN MAX INT EXT MUSIC ON HOLD CHIME TELE PAGING MIC 1 2 3 4 7 6 5 9 8 11 10 12 13 14 15 16 17 18 19 OUTPUT COM Const...

Страница 9: ...connecting microphones with phantom power to operate condenser type mics The ZM series also has a special priority feature so when you speak on the microphone the music is automati cally muted You can...

Страница 10: ...using an equipment rack such as one of the Samson SRK series To select a good location for your equipment rack you should consider several points including the proximity to each of the sound zones if...

Страница 11: ...mplifiers have built in transformers on each channel that step up the output voltage and reduce the current allowing you to connect to a series of speakers with step down transformers over long cable...

Страница 12: ...lly if multiple amplifiers are used in a rack Connecting the Speakers to the ZM Amplifier Make the speaker connections using the Euroblock output connectors on the rear panel It is never a good idea t...

Страница 13: ...l If your mixer has balanced outputs we recommend the use of three conductor cabling and connectors unbalanced two conductor connections can also be used but you ll get better signal quality and less...

Страница 14: ...S com plus equalizer like the Samson D2500 digital equalizer or feedback management systems like the Samson D3500 Connect the PRE AMP OUT to the input of the signal processor Then connect the output o...

Страница 15: ...eries constant voltage outputs are connected to two ceiling speakers in each of the Dining Rooms with their transformers set to a 12 watt tap The third constant voltage output powers two speakers in t...

Страница 16: ...older Points 1 2 3 Tip signal Sleeve ground Cold Pin 3 no connection Tip signal Sleeve ground 2 3 1 Male XLR Hot 2 Cold 3 Common 1 End View Solder Points 1 2 3 Tip signal Sleeve ground Cold Pin 3 no c...

Страница 17: ...PAY ATTENTION TO THE WARNING SYMBOL AND AVOID ELECTRICAL SHOCK DO NOT HOLD OR TOUCH THE COMMON AND 70 OR 100 VOLT WIRE CONNECTION WHILE OPERATING THE AMPLIFIER Follow the guidelines below to select th...

Страница 18: ...Ratio at rated power output Better than 90dB Crosstalk at all control maximum 70dB at 1kHz Rated Output Power at THD 0 36 60Watts 120Watts Total Harmonic Distortion THD at 1kHz rated power Less than 0...

Страница 19: ...15 Block Diagram...

Страница 20: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com...

Отзывы: