background image

10

Operating The ZM Series

Using Music On Hold 

The ZM series include a MOH (Music On Hold) function 

allowing you to connect the ZM series to a business 

telephone system. With MOH, when customers call in to the 

business and are put on hold, they hear background music 

from an external source or from the internal source if the 

optional TCM-3 tuner/CD player is installed.  You can make 

the call-in experience more pleasant or take advantage of 

valuable time by playing a pre-recorded commercial message 

using MOH.

You can set the volume of the MOH signal using the MOH 

Level control. 

Using the TELE-Paging function

You can connect the ZM75 and ZM 125 to a business 

telephone system using the TELE PAGING CONNECTOR 

allowing announcement paging from any telephone. Usually, 

the telephone system provides a dedicated output and has 

the ability to send a page using a certain extension number. 

Check the manufacturer's operating manual of the telephone 

system for operation detail.

Using External Effects AMP IN and PRE-AMP OUT

The ZM series provides a convenient patch point between the 

mixer and power amp allowing you to connect an external

signal processor like dynamics (like the Samson S com 

plus), equalizer (like the Samson D2500 digital equalizer) or 

feedback management systems (like the Samson D3500). 

Connect the PRE-AMP OUT to the input of the signal 

processor. Then, connect the output of the signal processor to 

the AMP IN to complete the circuit.

Expanding The ZM system using LINK IN / LINK OUT

If the system installation requires more inputs and outputs, 

you can use an external mixer or additional ZM series mixer/

amplifiers using the LINK IN and LINK OUT connectors. 

Connect the LINK out of the first ZM mixer/amp to the LINK in 

of the second.

Using The Graphic Equalizer

The ZM75 and ZM125 feature an onboard seven-band 

equalizer for adjusting the systems overall frequency 

response. The Equalizer includes seven filters, providing 12 

dB of cut and boost at 125Hz, 250Hz, 500Hz, 1kHz, 2kHz, 4kHz 

and 8kHz. You can use the equalizer to contour the system 

response for music or speech.  The Graphic EQ can also be 

useful for removing feedback. If feedback occurs, try lowering 

the mid range frequencies 1k and 2K.

 

If you encounter difficulty with any aspect of setting up or 

using your ZM Series,  contact your local Samson dealer.  If 

purchased in the United States, you can call Samson Technical 

Support (1-800-372-6766) between 9 AM and 5 PM EST.

EFFECTS PROCESSOR

INPUT

OUTPUT

1

2

3

4

5

6

7

8

9

*

0

#

1

2

3

4

5

6

7

8

9

*

0

#

+12dB

0 dB

-12dB

+12

0

-12

125Hz

250Hz

500Hz

1kHz

8kHz

2kHz

4kHz

Содержание ZM125

Страница 1: ...AX MIN MAX MIN MAX MIN MAX ALL ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 12dB 0 dB 12dB 12 0 12 125Hz 250Hz 500Hz 1kHz 8kHz 3 0 4 10 20 ON OFF MIN MAX 2kHz 4kHz SAMSON MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX...

Страница 2: ...NG TYPE PLUG POLARIZED PLUG HAS TWO BLADES WITH ONE WIDER THAN THE OTHER GROUNDING TYPE PLUG HAS TWO BLADES AND A THIRD GROUNDING PRONG 4HE WIDE BLADE OR THE THIRD PRONG ARE PROVIDED FOR YOUR SAFETY F...

Страница 3: ...or objects have fallen into the unit the unit has been exposed to rain or moisture does not operate normally or has been dropped PRECAUCION Para reducir el riesgo de incendios o descargas no permita q...

Страница 4: ...samsontech com Table of Contents Introduction 1 ZM Series Features 2 ZM Series Layout Front Panel 3 ZM Series Layout Rear Panel 4 Designing an Installation Plan 5 Operating The ZM Series 8 Operating...

Страница 5: ...he ZM75 and ZM125 can be table top or mounted in a standard 19 inch equipment rack using the included rack mount ears The sleek black finish matches just about any d cor plus the steel chassis adds to...

Страница 6: ...ce or pre recorded announcement to your telephone system A convenient telephone paging input on a Euroblock terminal allows you to interface your PBX system for handset paging 12dB 0 dB 12dB 12 0 12 1...

Страница 7: ...6 LEVEL control knob The six control knobs are used to set the individual level of the input sources 7 MASTER control knob This control knob adjusts the overall system volume 12dB 0 dB 12dB 12 0 12 1...

Страница 8: ...G C H G C H G C SW H LINK OUT PRE AMP OUT LINK IN AMP IN MAX VOLUME VOLUME MIN MAX MIN MAX INT EXT MUSIC ON HOLD CHIME TELE PAGING MIC 1 2 3 4 7 6 5 9 8 11 10 12 13 14 15 16 17 18 19 OUTPUT COM Const...

Страница 9: ...connecting microphones with phantom power to operate condenser type mics The ZM series also has a special priority feature so when you speak on the microphone the music is automati cally muted You can...

Страница 10: ...using an equipment rack such as one of the Samson SRK series To select a good location for your equipment rack you should consider several points including the proximity to each of the sound zones if...

Страница 11: ...mplifiers have built in transformers on each channel that step up the output voltage and reduce the current allowing you to connect to a series of speakers with step down transformers over long cable...

Страница 12: ...lly if multiple amplifiers are used in a rack Connecting the Speakers to the ZM Amplifier Make the speaker connections using the Euroblock output connectors on the rear panel It is never a good idea t...

Страница 13: ...l If your mixer has balanced outputs we recommend the use of three conductor cabling and connectors unbalanced two conductor connections can also be used but you ll get better signal quality and less...

Страница 14: ...S com plus equalizer like the Samson D2500 digital equalizer or feedback management systems like the Samson D3500 Connect the PRE AMP OUT to the input of the signal processor Then connect the output o...

Страница 15: ...eries constant voltage outputs are connected to two ceiling speakers in each of the Dining Rooms with their transformers set to a 12 watt tap The third constant voltage output powers two speakers in t...

Страница 16: ...older Points 1 2 3 Tip signal Sleeve ground Cold Pin 3 no connection Tip signal Sleeve ground 2 3 1 Male XLR Hot 2 Cold 3 Common 1 End View Solder Points 1 2 3 Tip signal Sleeve ground Cold Pin 3 no c...

Страница 17: ...PAY ATTENTION TO THE WARNING SYMBOL AND AVOID ELECTRICAL SHOCK DO NOT HOLD OR TOUCH THE COMMON AND 70 OR 100 VOLT WIRE CONNECTION WHILE OPERATING THE AMPLIFIER Follow the guidelines below to select th...

Страница 18: ...Ratio at rated power output Better than 90dB Crosstalk at all control maximum 70dB at 1kHz Rated Output Power at THD 0 36 60Watts 120Watts Total Harmonic Distortion THD at 1kHz rated power Less than 0...

Страница 19: ...15 Block Diagram...

Страница 20: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com...

Отзывы: