5 SERVICE, OPERATION, MAINTENANCE AND
INSPECTION INTERVALS
A failure to observe the inspection intervals described in table below may result in
damage to the pump
Section
Operation
Interval
5.1
Drain liquid separator to remove contaminants
Weekly
5.2
Check grease cartridges (if equipped)
Weekly
5.3
Winterization
When below 0°C
5.4
Lubrication of bearings
Per 500 duty hours
5.5
Inspection and cleaning of service liquid’s supply pipe
Monthly
5.6
Inspection and cleaning of internal channels
Monthly
5.1 Draining the liquid separator
While the pump is stopped, the liquid separator must be drained to remove contaminants.
5.2 Check grease cartridges
If the pump is equipped with an automatic lubrication feature. It must be inspected and
replaced as needed.
When the pump is commissioned for the first time, the cartridges must be activated by
turning the arrow in the clockwise direction.
The cartridge is set to 12, which corresponds to an emptying time of 12 months.
The cartridge must be replaced when empty.
It is only allowed to use automatic lubricator of type
LAGD 125/WA2
.
DOC3707
5.3 Winterization
If the pump needs to be used at a temperature below freezing point of the service liquid, it is necessary to
protect the liquid from freezing by adding anti freeze liquid.