6

between the parameters Input selection and Mic 
Gain.  You can edit the parameters of any of these 
functions by using the large Data Wheel located by 
the main LCD display.  

GLOBAL

The GLOBAL control allows you to set up the various 
system parameters including selecting the input/
output and control for the measurement micro-
phone input.

The Global Switch Has Two Clicks!

Click  Menu Function 

Value

Inp.   Input   

Opt 1, Opt 2, Mic

MG.   Mic Gain  

0 to + 60dB

Selecting the Input

The D1500 accepts inputs from any of the installed 
I/O boards including the optional DIO1 Digital I/O or 
AIO2, I/O board with premium analog-to-digital and 
digital-to-analog converters. You can load any com-
bination of these I/O boards in each of the Option 1 
or Option 2 card slots. You can also select the input 
from a connected measurement microphone here. 
To access the input follow these steps:

•   Press the GLOBAL control switch once or twice 

until you see the: Inp  …...

•   Use the Data Wheel to select OPT 1, OPT 2 or MIC.

NOTE: 

Once you make an edit to the Global set-up, the red 

GLOBAL LED will flash indicating that a change has been 
made to the original set-up.  You will also see that the red 
STORE LED is illuminated

•   To keep the new changes, press STORE again to 

confirm the change to be saved and you will exit the 
GLOBAL mode and both the STORE and GLOBAL the 
LED’s will turn off.

Using the D1500 as an RTA.

This section will take you through a quick set-up us-
ing the D1500 as a real time frequency analyzer. 

First, remove all packing materials (save them in case 
of need for future service) and decide where the unit 
is to be physically placed—it can be used free-stand-
ing or mounted in a standard 19” rack.

Before you move ahead, you should become familiar 
with the various control switch sections.  The D1500 
front panel switches are set up in groups related to 
the function or parts of the operating system they 
control.  Some switches are placed individually, since 
they are dedicated to a single function, and other 
switches, are arranged in groups since their function-
ality is related. The D1500 function switch sections 
are arranged on the front panel as follows: 

BY PASS
AUTO EQ
PARAMETERS
NAVAGATION 
GLOBAL
MIDI
LOAD and STORE

In this quick start example, we'll take you through 
the BYPASS and GLOBAL sections, as well as the NAV-
IGATION and PARAMETER sections.  AUTO EQ, MIDI 
and the LOAD and STORE switches and functions will 
be covered in detail later on in this manual.

You should know this!

Several of the modes that are controlled by the Navi-
gation switches, have a number of parameters as-
sociated that can be adjusted for finer control.  Each 
of these parameters will be explained in detail later 
on in this manual, however you should know that 
you can see these parameters by holding the mode 
switch for 2 seconds.  For example, if you press and 
hold the RTA switch for 2 seconds, you will see all the 
LED’s on the parameter switches light. That indicates 
that all these parameters can be adjusted in the RTA 
mode. If you press and hold the EQ switch for two 
seconds, no parameter switches LED’s light, indicat-
ing there are no adjustable parameters.

You should know this too !

Many of the D1500 control buttons are capable of 
accessing more than one parameter, so as you press 
the switch, you will page through the available pa-
rameters. For example, the GLOBAL switch will toggle 

D1500 Quick Start

Содержание D-150

Страница 1: ...DIGITAL 31 BAND REAL TIME ANALYZER...

Страница 2: ...ly cord or plug damage or if liquid has been spilled or objects have fallen into the unit the unit has been exposed to rain or moisture does not operate normally or has been dropped PRECAUCION Para re...

Страница 3: ...Res Resolution 9 Hold 9 Freq Frequency 9 Using The Analyze Mode 9 Using The D1500 s Eq Display 10 Operating The Phase Meter 10 Using The D1500 As A Vu Meter 10 Using The D1500 As A Signal Generator 1...

Страница 4: ...ith the DN1 D Net network card Samson s D Net is a high speed communication protocol for connected multiple D class units like the D2500 digital equalizer or D3500 feedback management system In additi...

Страница 5: ...to a large VU Level meter that simultaneously displays both Peak and VU levels A comprehensive Signal Generator capable of producing White and Pink Noise as well as a tunable Sine Wave can be used to...

Страница 6: ...n modes 10 DETECT Selects the RTA to operate with either RMS average or PEAK detection Controls and Functions Front Panel Layout 11 INTER INTEGRATION Used in conjunction with DETECT to adjust the RTA...

Страница 7: ...o 99 programs into the internal memory 27 Main Level Meter Twelve segment LED meter displays the input level A POWER SWITCH When set to the ON position the D1500 is powered up and ready for operation...

Страница 8: ...is to be physically placed it can be used free stand ing or mounted in a standard 19 rack Before you move ahead you should become familiar with the various control switch sections The D1500 front pane...

Страница 9: ...ecial microphone usually a con denser microphone designed to pick up sound with an extended frequency range linear or flat response and a natural sound A perfect choice for this is the Samson MM01 Mea...

Страница 10: ...about two seconds and take no tice of the parameters that can be adjusted while using the RTA You ll notice that the SOURCE GAIN DETECT INTEG WEIGHT REF RES HOLD and FREQ are all illumi nated indicati...

Страница 11: ...EVEL Sets the LCD display reference level for use with the ANALYZE mode RES RESOLUTION The D1500 RTA LED meter s can be software set to display different ranges of level using the RESOLU TION paramete...

Страница 12: ...Right input Press the PHASE switch to select the D1500 to phase meter mode If the audio is in phase the Phase meter will read all the way to the right When the D1500 measures an out of phase signal th...

Страница 13: ...Generator Before you get started using the Generator press and hold the GEN switch for about two seconds and take notice of the parameters that can be adjusted while using the Generator You ll notice...

Страница 14: ...ogram number to save under simply press the STORE button again and your set up is saved and can be easily recalled using the LOAD function Loading Programs in the D1500 You can load presets with store...

Страница 15: ...les for IN OUT and THRU to configure a system using traditional MIDI protocol For critical applications where high speed commu nication is needed you can install optional DN1 D net interface cards and...

Страница 16: ...transmit sys tem exclusive messages use the Data Wheel to select SysEx T R Press STORE Use the Data Wheel to select SysEx OFF and the D1500 will not transmit or receive any system exclu sive messages...

Страница 17: ...s F R Now turn the Data Wheel until the dispay reads 12 dB Press the D2500 s Global switch a few times until the display reads F Bw Then turn the Data Wheel until the display reads 1 3 Oct Press STORE...

Страница 18: ...g the D1500 with the D2500 Digital EQ Press RES and use the Data Wheel to select 2 0 dB which will correspond to the D2500 provided that the Frequency Range Global Menu of the D2500 is set to the defa...

Страница 19: ...Data Wheel clockwise until the LED indica tors are operating in a range approximately halfway up the display Operating the D1500 Operating the D1500 Using the signal Generator The D 1500 s internal Si...

Страница 20: ...or for any EQ response curve that you may have saved in memory THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES CLASS B OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MUST NOT CA...

Страница 21: ...see MG and select 30dB to start then press STORE NOTE You may need to come back to this to make the final mic gain adjustment once you start generat ing the PINK NOISE at the desired operating level...

Страница 22: ...once or twice until you see MG then turn the data wheel clockwise and confirm by press ing STORE Be sure to Check the D1500 s Main VU meter as well to set the proper mic level If the Pink Noise sounds...

Страница 23: ...equency signal may be relatively small the negative effects can be substantial The problem is that both drivers are reproducing frequencies at and around the crossover point which arrive at the listen...

Страница 24: ...e the D1500 s Signal Generator to produce a frequency tone tuned to the crossover frequency or use the Pink Noise generator and connect the test tone to your loudspeaker system either from your mixer...

Страница 25: ...imize possible interference by planning your audio electrical and computer cable runs so that they are as far apart from one another as possible and so they don t run parallel to one another If they h...

Страница 26: ...e advantage of CMR Common Mode Rejection we recommend using balanced cables when ever and where ever possible Follow the cable diagrams below for connecting your RTA Balanced XLR to XLR Cable Balanced...

Страница 27: ...Digital Processing Converter 24 bit Delta Sigma 64 128 oversampling Sample rate AIO1 AIO2 32 44 1 48 64 88 2 96 kHz DIO1 96 kHz Type digital 31 band FFT analyzer Frequency range 20 Hz to 20 kHz 31 ban...

Страница 28: ...Samson Technologies Corp 575 Underhill Blvd P O Box 9031 Syosset NY 11791 9031 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 516 364 3888 www samsontech com...

Отзывы: