Samson D-150 Скачать руководство пользователя страница 19

17

•   Now run your mic, MP3, or CD player signal, press 

RTA on the D1500 and check the LCD Meters on 
the D1500.  

•   While the D1500 is set to RTA, you may need to 

adjust the GAIN to set the reference point of the 
display.

Once you confirm that the system is operating nor-
mally and that the RTA can read the system response 
with the test mic, you can move ahead and generate 
the Pink Noise to help you flatten the system. 
•   Connect the D1500 Left and Right Outputs to a 

pair of inputs on your mixing console.

•   Now make sure that the input gain controls and 

faders on the inputs on your mixers have the 
D1500 outputs connected and turned up to about 
0dB.

•  Press the GEN switch on the D1500.
•   To change the operating level reference scale press 

the REF switch and use the Data Wheel to make 
the change.

•   To be extra safe with your gear (this may get really 

loud! really!), start with a very low signal level by 
selecting the GAIN switch and turning the Data 
Wheel counter-clockwise all the way to –98dB.

•   Next, press the SOURCE switch and turn the Data 

Wheel until the display reads: SRC: PINK.

•   To turn up the Pink Noise signal, make sure that 

GEN is still selected and then press the GAIN switch 
and turn the Data Wheel clockwise until your hear 
the level of the pink Noise get about as loud as the 
system was when you played your mic, MP3, or CD 
player signal,

•   Now, press the RTA switch and you should see the 

various frequency meters bouncing along.  

 If the LED meters read very low on the display, or you 
don’tsee them at all, you will need to do one, or a 
combination, of the following:  
1 - Press Global and use the data wheel to select 
MG (Mic Gain). Next, turn the Data Wheel clockwise 
to increases the Mic Gain in 10 dB steps. Press the 
STORE switch to accept the change. Repeat this step 
until the LED indicators are operating in a range 
approximately halfway up the display.
2 - Press the RTA switch and then the GAIN switch. 
Turn the Data Wheel clockwise until the LED indica-
tors are operating in a range approximately halfway 
up the display.

Operating the D1500  

Operating the D1500  

Using the signal Generator

The D 1500’s internal Signal Generator can be used 
to produce Pink Noise, White Noise or a tunable Sine 
Wave.
You can use the Generator for a variety of applica-
tions including using the Pink Noise signal to flatten 
the response curve of a speaker system with an ana-
log equalizer, or using the Sine Wave to output a sine 
wave for tuning a crossover at a specific frequency.

Before you get started using the Generator, press and 
hold the GEN switch for about two seconds and take 
notice of the parameters that can be adjusted while 
using the Generator. You’ll notice that the SOURCE, 
GAIN, REF and FREQ are illuminated indicating that 
these parameters can be edited.

The following example outlines a typical application 
for using the D1500’s RTA and Pink Noise Generator 
to flatten a loudspeaker system in a small to medium 
size venue using a traditional analog graphic equal-
izer.
•   Connect your mixer, equalizer and power amplifiers 

as you normally would and confirm that you have 
normal output by playing a signal like that from a 
mic, MP3, or CD player. It’s a good idea to set the 
system to the same level that you will be ultimately 
using during normal operation.  Once you get the 
system up and running mute the mic/MP3/CD, but 
keep set up so you can use it to set the measure-
ment mic level.

•   Connect a measurement microphone like the 

Samson MM01 to the D1500 rear panel MIC INPUT. 
Place the microphone on a stand and position it 
about ear level, approximately 3 meters, or 10 feet, 
from your speaker. 

Note:

The proper spot to position the measurement 

microphone will vary depending on the size of the 
space the loudspeaker system is operating in.  

•   Press the Global switch once or twice until you see 

Inp in the LCD display, then select Mic and press 
STORE

•   Press Global again, and use the Data Wheel to set 

a Mic Gain of +20 dB to start.  Press store. You may 
need to adjust the Mic GAIN up or down depend-
ing on your exact situation.

Содержание D-150

Страница 1: ...DIGITAL 31 BAND REAL TIME ANALYZER...

Страница 2: ...ly cord or plug damage or if liquid has been spilled or objects have fallen into the unit the unit has been exposed to rain or moisture does not operate normally or has been dropped PRECAUCION Para re...

Страница 3: ...Res Resolution 9 Hold 9 Freq Frequency 9 Using The Analyze Mode 9 Using The D1500 s Eq Display 10 Operating The Phase Meter 10 Using The D1500 As A Vu Meter 10 Using The D1500 As A Signal Generator 1...

Страница 4: ...ith the DN1 D Net network card Samson s D Net is a high speed communication protocol for connected multiple D class units like the D2500 digital equalizer or D3500 feedback management system In additi...

Страница 5: ...to a large VU Level meter that simultaneously displays both Peak and VU levels A comprehensive Signal Generator capable of producing White and Pink Noise as well as a tunable Sine Wave can be used to...

Страница 6: ...n modes 10 DETECT Selects the RTA to operate with either RMS average or PEAK detection Controls and Functions Front Panel Layout 11 INTER INTEGRATION Used in conjunction with DETECT to adjust the RTA...

Страница 7: ...o 99 programs into the internal memory 27 Main Level Meter Twelve segment LED meter displays the input level A POWER SWITCH When set to the ON position the D1500 is powered up and ready for operation...

Страница 8: ...is to be physically placed it can be used free stand ing or mounted in a standard 19 rack Before you move ahead you should become familiar with the various control switch sections The D1500 front pane...

Страница 9: ...ecial microphone usually a con denser microphone designed to pick up sound with an extended frequency range linear or flat response and a natural sound A perfect choice for this is the Samson MM01 Mea...

Страница 10: ...about two seconds and take no tice of the parameters that can be adjusted while using the RTA You ll notice that the SOURCE GAIN DETECT INTEG WEIGHT REF RES HOLD and FREQ are all illumi nated indicati...

Страница 11: ...EVEL Sets the LCD display reference level for use with the ANALYZE mode RES RESOLUTION The D1500 RTA LED meter s can be software set to display different ranges of level using the RESOLU TION paramete...

Страница 12: ...Right input Press the PHASE switch to select the D1500 to phase meter mode If the audio is in phase the Phase meter will read all the way to the right When the D1500 measures an out of phase signal th...

Страница 13: ...Generator Before you get started using the Generator press and hold the GEN switch for about two seconds and take notice of the parameters that can be adjusted while using the Generator You ll notice...

Страница 14: ...ogram number to save under simply press the STORE button again and your set up is saved and can be easily recalled using the LOAD function Loading Programs in the D1500 You can load presets with store...

Страница 15: ...les for IN OUT and THRU to configure a system using traditional MIDI protocol For critical applications where high speed commu nication is needed you can install optional DN1 D net interface cards and...

Страница 16: ...transmit sys tem exclusive messages use the Data Wheel to select SysEx T R Press STORE Use the Data Wheel to select SysEx OFF and the D1500 will not transmit or receive any system exclu sive messages...

Страница 17: ...s F R Now turn the Data Wheel until the dispay reads 12 dB Press the D2500 s Global switch a few times until the display reads F Bw Then turn the Data Wheel until the display reads 1 3 Oct Press STORE...

Страница 18: ...g the D1500 with the D2500 Digital EQ Press RES and use the Data Wheel to select 2 0 dB which will correspond to the D2500 provided that the Frequency Range Global Menu of the D2500 is set to the defa...

Страница 19: ...Data Wheel clockwise until the LED indica tors are operating in a range approximately halfway up the display Operating the D1500 Operating the D1500 Using the signal Generator The D 1500 s internal Si...

Страница 20: ...or for any EQ response curve that you may have saved in memory THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES CLASS B OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MUST NOT CA...

Страница 21: ...see MG and select 30dB to start then press STORE NOTE You may need to come back to this to make the final mic gain adjustment once you start generat ing the PINK NOISE at the desired operating level...

Страница 22: ...once or twice until you see MG then turn the data wheel clockwise and confirm by press ing STORE Be sure to Check the D1500 s Main VU meter as well to set the proper mic level If the Pink Noise sounds...

Страница 23: ...equency signal may be relatively small the negative effects can be substantial The problem is that both drivers are reproducing frequencies at and around the crossover point which arrive at the listen...

Страница 24: ...e the D1500 s Signal Generator to produce a frequency tone tuned to the crossover frequency or use the Pink Noise generator and connect the test tone to your loudspeaker system either from your mixer...

Страница 25: ...imize possible interference by planning your audio electrical and computer cable runs so that they are as far apart from one another as possible and so they don t run parallel to one another If they h...

Страница 26: ...e advantage of CMR Common Mode Rejection we recommend using balanced cables when ever and where ever possible Follow the cable diagrams below for connecting your RTA Balanced XLR to XLR Cable Balanced...

Страница 27: ...Digital Processing Converter 24 bit Delta Sigma 64 128 oversampling Sample rate AIO1 AIO2 32 44 1 48 64 88 2 96 kHz DIO1 96 kHz Type digital 31 band FFT analyzer Frequency range 20 Hz to 20 kHz 31 ban...

Страница 28: ...Samson Technologies Corp 575 Underhill Blvd P O Box 9031 Syosset NY 11791 9031 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 516 364 3888 www samsontech com...

Отзывы: