![background image](http://html1.mh-extra.com/html/samson/6132/6132_mounting-and-operating-instructions_3798053012.webp)
3-2
EB 6132 EN
Design and principle of operation
3.1
Technical data
Type
Type 6132-04
Version
Rail-mounting unit
Input
Input 0.2 to 1 bar (3 to 15 psi), overloadable up to 2 bar
Selected using switches inside the
device
0 to 20 mA · 4 to 20 mA
0 to 10 V · 2 to 10 V · 0 to 5 V · 1 to 5 V
Permissible load
0/4 to 20 mA
≤ 750 Ω at 20 mA
0/2 to 10 V
≥ 2 kΩ
Supply voltage
24 V DC (18 to 36 V) 1.5 W;
230 V AC, 115 V AC, 24 V AC
(–15/+10 %) 50/60 Hz, 3 VA
Characteristic
1)
Characteristic
Output linear to input
Hysteresis
≤ 0.05 %
Deviation from terminal-based linearity
≤ 0.02 %
Dead band
≤ 0.03 %
Ripple of output signal
≤ 0.05 %
Effect of temperature
≤ 0.15 %/10 K for zero and span
EMC noise emission
EN 61000-6-3, EN 61326
EMC noise immunity
EN 61000-6-2, EN 61326
Device safety
EN 61010
Class of protection
I
Overvoltage category
II
Degree of contamination
2
Ambient conditions, degree of protection, weight
Permissible ambient temperature
–20 to +70 °C
Perm. storage temperature
–40 to +85 °C
Perm. transportation temperature
–40 to +85 °C
Degree of protection acc. to EN 60529
IP 20
Conformity
Weights
AC supply voltage
Approx. 0.32 kg
DC supply voltage
Approx. 0.25 kg
Содержание 6132
Страница 4: ...Contents EB 6132 EN 13 Disposal 13 1 14 Certificates 14 1 15 Annex 15 1 15 1 After sales service 15 1...
Страница 10: ...2 2 EB 6132 EN...
Страница 14: ...3 4 EB 6132 EN...
Страница 20: ...5 4 EB 6132 EN Installation...
Страница 22: ...6 2 EB 6132 EN...
Страница 24: ...7 2 EB 6132 EN...
Страница 30: ...10 2 EB 6132 EN...
Страница 32: ...11 2 EB 6132 EN...
Страница 34: ...12 2 EB 6132 EN...
Страница 36: ...13 2 EB 6132 EN...
Страница 39: ...EB 6132 EN 14 3...
Страница 40: ...14 4 EB 6132 EN...
Страница 42: ...15 2 EB 6132 EN...
Страница 43: ......