![background image](http://html1.mh-extra.com/html/samson/15-pw/15-pw_owners-manual_3825296004.webp)
pipe Dn28 must be used to connect the water jacket to the system. The application of smaller
diameter pipes is prohibited. The water system must be equipped with a water overflow tank
in compliance with the binding regulations (See: figure below)
INSTALLATION DIAGRAM FOR SAMSON 15 PW
Specification
1 – the stove Samson 15 PW
5 – water supply from the water mains
2 - central heating installation
6 – expansion pipe –EP
3 - open compensation tank
7 – safety pipe – SP
4 – overflow pipe – OP
It is essential that the safety pipe (SP), expansion pipe (EP) and overflow pipe (OP) be made
of steel or copper with the diameters specified below:
SP-steel- 1”, copper – Dn28
EP-steel- 1”, copper – Dn28
OP-steel- 1”, copper – Dn28
It is strictly prohibited to mount any cut-off devices on water piping.
It is recommended to use a water intake steel pipe from the cut-off valve to the expansion tank
to protect the same against overheating, since the water temperature may occasionally exceed
95°C (to the detriment of the piping, e.g. made of plastic). The intake pipe diameter should be
1
/
2
” or
3
/
4
”. All pipes mounted in unheated rooms as well as the expansion valve should be
insulated to protect them against freezing and/or damage to the water jacket.
Water jacket assembly guidelines
To ensure the satisfactory, safe and problem-free use of the stove with a water jacket, the
following guidelines are recommended.
It is of utmost importance that the water jacket be connected by authorised and experienced
professionals. The same principle applies to flue gas outlet pipes. Failure to comply with the
binding norms and regulations or any installation errors may jeopardise your life. Therefore,
in order to fully enjoy the system, only professional installation firms should be employed.
To improve the functioning of Samson 15 PW water jacket, we recommend the application of
an open overflow/buffer tank with a float and automatic water replenishing system to ensure
smooth operation of the system and protect the water jacket against damage due to inadequate