background image

pipe Dn28 must be used to connect the water jacket to the system. The application of smaller 
diameter pipes is prohibited. The water system must be equipped with a water overflow tank 
in compliance with the binding regulations (See: figure below)  
 

INSTALLATION DIAGRAM FOR SAMSON 15 PW 

 

 

Specification  

 

1 – the stove Samson 15 PW 

5 – water supply from the water mains 

2 - central heating installation 

6 – expansion pipe –EP 

3 - open compensation tank 

7 – safety pipe – SP 

4 – overflow pipe – OP 

 

 
It is essential that the safety pipe (SP), expansion pipe (EP) and overflow pipe (OP) be made 
of steel or copper with the diameters specified below:  
SP-steel- 1”, copper – Dn28  
EP-steel- 1”, copper – Dn28  
OP-steel- 1”, copper – Dn28  
 

It is strictly prohibited to mount any cut-off devices on water piping. 

 
It is recommended to use a water intake steel pipe from the cut-off valve to the expansion tank 
to protect the same against overheating, since the water temperature may occasionally exceed 
95°C (to the detriment of the piping, e.g. made of plastic). The intake pipe diameter should be 

1

/

2

”  or 

3

/

4

”.  All  pipes  mounted  in  unheated  rooms  as  well  as  the  expansion  valve  should  be 

insulated to protect them against freezing and/or damage to the water jacket.  
 
Water jacket assembly guidelines  
To  ensure  the  satisfactory,  safe  and  problem-free  use  of  the  stove  with  a  water  jacket,  the 
following guidelines are recommended.  
It  is  of  utmost  importance  that  the  water  jacket  be  connected  by  authorised  and  experienced 
professionals. The same principle applies to flue gas outlet pipes. Failure to comply with the  
binding norms and regulations or any installation errors may jeopardise  your life. Therefore, 
in order to fully enjoy the system, only professional installation firms should be employed.  
 
To improve the functioning of Samson 15 PW water jacket, we recommend the application of 
an open overflow/buffer tank with a float and automatic water replenishing system to ensure 
smooth operation of the system and protect the water jacket against damage due to inadequate 

Содержание 15 PW

Страница 1: ...OWNER S MANUAL WOOD STOVE with a Water Jacket SAMSON 15 PW...

Страница 2: ...joyment Install and use the stove with due diligence and in accordance with local codes The water part must be connected to the central heating open installation system in compliance with local norms...

Страница 3: ...es may cause problems The room where the stove is located should have at least 12m of floor area The wall against which the stove is installed and the floor in front of the stove must be made from non...

Страница 4: ...ter temperature may occasionally exceed 95 C to the detriment of the piping e g made of plastic The intake pipe diameter should be 1 2 or 3 4 All pipes mounted in unheated rooms as well as the expansi...

Страница 5: ...ely protected in compliance with local norms provided that open and closed central hating systems are separated by means of a heat exchanger Establishing the first fire Before establishing the first f...

Страница 6: ...ove must not be installed in a place where there is a lot of human traffic Flammable materials must be kept at least 1 5 m away from the hearth To avoid burns make sure that children stay away from th...

Страница 7: ...hazard Do not overfire Do not modify air inlets in any way Do not disassembly the burning chamber Do not put out the fire with water Do not burn coal coke chipboard chemically treated wood plastics or...

Страница 8: ...Glass cleaning Allow the glass to cool before cleaning There is a variety of special glass cleaners available on the market Read instructions before using them Do not use abrasive cleaners to clean t...

Отзывы: