Dimension and technical specification for Samson 15 PW 

 
 

Unit external dimensions: 
Height: 730  mm   

Width: 730 mm 

 

Depth: 450 mm 

 
Weight 194 kg 
 
Flue outlet: 
Flue pipe diameter Dn 160 
1-connector pipe 1” – male thread 1” 
 
Nominal power 7,5 kW 
Water jacket capacity 10 l 
 
 

 

 

 
Introduction  
Thank you for choosing SAMSON 15 PW wood stove with water jacket. It is important that 
you  read  carefully  all  instructions  before  installing  and  using  the  stove.  Understanding  the 
instructions and guarantee terms will ensure safety of operation and your lasting enjoyment.  
Install and use the stove with due diligence and in accordance with local codes. The water part 
must  be  connected  to  the  central  heating  open  installation  system  in  compliance  with  local 
norms of heating and heat engineering.  
Careless installation is a major cause of safety hazard, including fire.  
When in doubt, contact a chimney inspector and/or a building administrator.  
The  unit  is  made  up  of  cast  iron  elements  put  together  by  means  of  fire-proof  mastics.  The 
water jacket is made of a high grade 5 mm thick boiler steel.  
 
Before connecting the stove to a chimney flue servicing, have it inspected and approved 
by an authorised chimney inspector.  
The results of such inspection should be confirmed in the form provided below. 
 
 

Содержание 15 PW

Страница 1: ...OWNER S MANUAL WOOD STOVE with a Water Jacket SAMSON 15 PW...

Страница 2: ...joyment Install and use the stove with due diligence and in accordance with local codes The water part must be connected to the central heating open installation system in compliance with local norms...

Страница 3: ...es may cause problems The room where the stove is located should have at least 12m of floor area The wall against which the stove is installed and the floor in front of the stove must be made from non...

Страница 4: ...ter temperature may occasionally exceed 95 C to the detriment of the piping e g made of plastic The intake pipe diameter should be 1 2 or 3 4 All pipes mounted in unheated rooms as well as the expansi...

Страница 5: ...ely protected in compliance with local norms provided that open and closed central hating systems are separated by means of a heat exchanger Establishing the first fire Before establishing the first f...

Страница 6: ...ove must not be installed in a place where there is a lot of human traffic Flammable materials must be kept at least 1 5 m away from the hearth To avoid burns make sure that children stay away from th...

Страница 7: ...hazard Do not overfire Do not modify air inlets in any way Do not disassembly the burning chamber Do not put out the fire with water Do not burn coal coke chipboard chemically treated wood plastics or...

Страница 8: ...Glass cleaning Allow the glass to cool before cleaning There is a variety of special glass cleaners available on the market Read instructions before using them Do not use abrasive cleaners to clean t...