background image

DigiKEY

Inserters

elektronik

Sams elektronik d.o.o. • [email protected] • www.sams.rs

4

TECHNICAL SUPPORT AND SERVICE

Sams elektronik has made every effort to ensure that the equipment works in perfect condition. In 

the event that problems that occur can not be resolved, or if you have any questions regarding this 

equipment or information about other products produced from Sams elektronik, contact your local sales 

representative or call Sams elektronik directly through one of the ways listed below:

Sales: +381 11 3806 254

Technical support: +381 11 2402 212

Service: +381 11 4056 051

Email: 

Sales - [email protected]

Technical support and service - [email protected]

Web site: www.sams.rs

Address: 

SAMS ELEKTRONIK d.o.o.

48 Zivka Davidovica st

11050 Belgrade

Serbia

WARNING

TO AVOID ELECTRIC SHOCK, DO NOT OPEN COVER.

DEVICE MAINTENANCE REQUIRES PROFESSIONAL PERSON AUTHORIZED BY THE MANUFACTURER.
1.   Read all safety and operating instructions before using the device.

2.   Keep all safety and operating instructions.

3.   Follow the instructions from the user manual.

4.   Do not upgrade device, except in the case advised by the manufacturer.

5.   Do not use the device in the presence of water and / or moisture.

6.  Do not pour water or moisten the device with any type of liquid.

7.   Openings on device are provided for ventilation.

8.  Do not block air flow through the ventilation openings.

9.   This product is powered by AC ~ 230V ± 10%, 50Hz.

10.   This product is equipped with a three-wire cord with grounding.

11.  This device is equipped with a protective fuse in the power outlet. Do not bypass fuse.

12.  Do not replace the fuse. Replacement can be made by a person authorized by the manufacturer.

13.   Do not bend the power cord so that it can be damaged.

14.  Connect connectors as in the enclosed instructions. Deviations from the allowed values predicted 

for the inputs and outputs of the device can cause severe damage and warranty void.

15.  Do not use the device in an environment that contains flammable or explosive materials in any 

physical state.

16.   Turn off the power corde before cleaning. Do not use liquid, aerosol or flammable cleaners. Use 

only a dry cloth.

17.   Servicing  is  performed  by  a  qualified  person.  Removing  the  cover  user  is  exposed  to  high 

voltages.

18.   Never use the device when the cover is open and the device is powered on.

19.  Do not expose to extreme high or low temperatures.

20.  Do not expose to sudden temperature changes.

21.   Call service in the following cases:

 

- The power cord or plug is damaged

 

- Liquid or foreign objects is inside the device

 

- The machine is exposed to water and moisture

 

- The device does not function according to specification

 

- The unit has been dropped or damaged

 

- The characteristics are significantly changed 

22.   Use only specified replacement parts. 

23.   Professional person authorized by the manufacturer must check the device after completion of 

service.

24.   Allow a free rack unit (1RU) above and below the device for ventilation or put rack fan under the 

device.

Pictures and drawings listed in this user manual are for information purposes only and may differ 

from the actual device. Design and specifications of the device may change without prior notice.

Содержание DigiKEY-1

Страница 1: ... 06 november 2014 Z10 3 edition 1 Code 004 108 ENGLISH Sams elektronik d o o 48 Zivka Davidovica st 11050 Belgrade Serbia Tel Fax 381 11 3806 253 381 11 2402 212 sams sams rs www sams rs Read the instructions before using the device Keep this manual for periodic usage USER MANUAL FOR USE AND MAINTENANCE ...

Страница 2: ...urer servicer has not completed repair or replacement within a reasonable time or if the manufacturer servicer did not perform repair or replacement without significant inconvenience to the consumer 5 The consumer may not terminate the contract if the lack of conformity of the product is negligible 6 The product will function properly when used in accordance with the user manual 7 Period of servic...

Страница 3: ...igh voltage In poor conditions the user may be exposed to shock The symbol exclamation mark in a triangle is to alert the user to comply by the terms of use in user s manual which is supplied with the device SAFETY WARNINGS ELECTRICAL SHOCK HAZARD DO N OT O PEN CAUTION RIZIK OD S TRUJNOG UDARA NE O TVARATI DOK JE P OD N APONOM UPOZORENJE CLASS I DEVICE Grounding is connected to the chassis of the ...

Страница 4: ...ice is equipped with a protective fuse in the power outlet Do not bypass fuse 12 Do not replace the fuse Replacement can be made by a person authorized by the manufacturer 13 Do not bend the power cord so that it can be damaged 14 Connect connectors as in the enclosed instructions Deviations from the allowed values predicted for the inputs and outputs of the device can cause severe damage and warr...

Страница 5: ...NSTALLATION 8 FUNCTIONS 8 BLOCK DIAGRAM 9 GRAPHIC CONFIGURATION 9 NETWORK SETUP 10 NETWORK ACCESS AND DEVICE CONTROL 10 HORISONTAL DELAY 12 VERTICAL DELAY 12 FADE IN TIME 12 FADE LEVEL 12 SELF KEY LEVEL 12 GPI ACTIVE 12 TEST 13 IP ADDRESS SUBNET MASK AND GATEWAY 13 PROBLEMS AND SOLUTIONS IN A NETWORK ENVIRONMENT 13 NOTES 16 Page Description TABLE OF CONTENTS ...

Страница 6: ...e device must be stored in a room without moisture The system maintains only person authorized by Sams elektronik doo Any voluntarily opening device upgrading or servicing is strictly prohibited and is subject to warranty void and the possibility of injury Places for fastening PROCEDURES FOR SAFE USE OF THE DEVICE 1 Remove the protective wrap from the chassis For devices that are AC 230V 50Hz powe...

Страница 7: ...onizer Lock on analog BB reference or on to SDI PGM Low jitter 0 2UI 10Hz Bypass relay protection for PGM Analog preview output Programable fade time Programable fade level TECHNICAL SPECIFICATIONS GENERAL INFORMATION Code 004 108 Weight 2 Kg Type 1RU rack frame Dimensions 1RU x 19 x 100mm Delivery includes device power corde user manual DIGITAL INPUT Number 3 program relay bypass key fill BNC fem...

Страница 8: ... to the video mixer External reference input Device supports signal generator like Sams MSG 2 SDI input SDI FILL input SDI KEY input SDI output CVBS monitoring SDI linear keyer DigiKEY 1 www sams co yu T C P I P G P I R E F K E Y F I L L P G M 1 T C P I P G P I R E F K E Y F I L L P G M 2 3 4 5 6 INSTALLATION FUNCTIONS When device is ON For best signal quality use Belden 1694A coaxial cable for SD...

Страница 9: ... sams sams rs www sams rs elektronik 9 BLOCK DIAGRAM GRAPHIC CONFIGURATION TCP IP PROGRAM IN PROGRAM OUT FILL IN ALPHA KEY IN ALPHA KEY CVBS OUT FOR MONITORING PROGRAM SDI OUT GPI FILL PROGRAM SDI IN ANALOG REFERENCE WEB BROWSER VIDEO MIXER ...

Страница 10: ...he device will be assigned a new address If there is a problem with connecting the device check the firewall and allow UDP port 3040 NOTE The device will be found from across the network only if the device was connected to a network cable before turning on If the program NETFINDER does not find the device on the network try the following Connect the inserter directly to the computer The computer s...

Страница 11: ...DigiKEY Inserters Sams elektronik d o o sams sams rs www sams rs elektronik 11 After a few seconds the next page will open Web browser welcome screen Web browser configuration ...

Страница 12: ...u to set the level of transparency from 0 to 100 over settings in alpha key in Note This setting can not be seen on the analog output for monitoring At the bottom of the page you can see the status of the device PGM Program input If it s green it s OK If it is red check cable or program source FILL if it is green everything is OK If it is red check cable or fill source KEY if it is green everythin...

Страница 13: ...dresa uređaja je 192 168 0 200 Ukoliko je adresa zauzeta povezati uređaj sa kompjuterom preko TCP IP u lokalu i tada promeniti adresu uređaju Ukoliko postoji problem sa povezivanjem uređaja proveriti firewall i dozvoliti port UDP 3040 If the software NETFINDER is not able to locate the device in the network try the following 1 Right click on Local Area Connection 2 Select option Change Windows Fir...

Страница 14: ...DigiKEY Inserters elektronik Sams elektronik d o o sams sams rs www sams rs 14 4 Click on button Add program 5 Click button Browse 6 Select application NETFINDER 8 Click Open and OK OK and OK ...

Страница 15: ...ng hands 8 Click on that icon 9 In the opened window click the button Add new 10 Enter the MAC address of the device MAC address is entered without dashes dots and spaces and press OK 11 If the field is not marked with the MAC address of the device click on it 12 In the right part of the window in the drop down menu instead of Ask me choose Automaticallz process the request 13 In the IP Address fi...

Страница 16: ...DigiKEY Inserters elektronik Sams elektronik d o o sams sams rs www sams rs 16 NOTES ...

Отзывы: