background image

6  |  SAMLEX AMERICA INC. 

SECTION 4 |

 INSTALLATION

4.1   Please refer to Fig. 1. The Remote Control can be flush mounted on a wall 

or a panel by making a suitable cut-out to accommodate the projection in 
the back. 

4.2   Please ensure that the inverter PST-3000-12 / PST-3000-24 is switched OFF 

before connecting RC-300 to the inverter.

4.3   Connect one end of the cable set to the RJ-50 Modular Jack (7) at the 

back and the Remote and the other end to the RJ-50 Modular Jack on the 
inverter. Ensure that the connection is firm and the tab on the plug securely 
locks in the jack. 

SECTION 5 | 

OPERATION

NOTE:
This Remote Control will operate only after the inverter PST-3000-12 / PST-3000-24 
has been first switched ON using the local ON/OFF Switch on the inverter or 
using the external ON/OFF control provided on the inverter (for details, please 
refer to Section 8 of Owner's Manual for PST-3000-12 / PST-3000-24 under head-
ing "Optional Wired Remote Control - Model RC-300).

5.1   Switch ON PST-3000-12 / PST-3000-24 using the local ON/OFF Switch on the 

inverter or using external ON/OFF control provided on the inverter (for de-
tails, please refer to Section 8 of Owner's Manual for PST-3000-12 / PST-3000-
24 under heading "Optional Wired Remote Control - Model RC-300). Once 
the inverter turns ON, the operational status of the inverter will be displayed 
through the LCD screen (3, Fig 1) and LEDs (4, 5, 6; Fig 1).

5.2   See under headings “LCD Display” (Section 3.3 and 3.4) and “LED Display” 

(Section 3.5)  for information on the operating conditions. Please read Sec-
tion 11 - "Troubleshooting Guide" of the Owner's Manual for PST-3000-12 / 
PST-3000-24 for identifying abnormal conditions indicated by the LEDs.

5.3   The output of the inverter can be switched ON/OFF using the ON/OFF Push 

Button (1, Fig 1).

5.4  No Load Current Draw 

As stated above, the ON/OFF Switch on the inverter is required to be in ON 
condition for the Remote to operate. When the ON/OFF switch on the Remote 
Control is turned ON, all the circuitry inside the inverter becomes fully alive and 
the AC output is made available. In this condition, even when no load is being 
supplied (or, if a load is connected but has been switched OFF), the inverter 
draws a small amount of current from the batteries to keep the circuitry alive 
and is ready to deliver the required power on demand. This is called the “idle 

Содержание RC-300

Страница 1: ...Remote Control for Inverter RC 300 Please read this manual BEFORE operating your RC 300 Remote Control Owner s Manual ...

Страница 2: ...OWNER S MANUAL Index SECTION 1 Safety 3 SECTION 2 Description 3 SECTION 3 Layout of Controls Indications Dimensional Drawings 3 SECTION 4 Installation 6 SECTION 5 Operation 6 SECTION 6 Specifications 7 SECTION 7 Warranty 8 ...

Страница 3: ... dimen sional drawing 3 2 ON OFF Control ON OFF Push Button 1 is used to switch ON and switch OFF the inverter Every time the ON OFF Push Button is pressed a beep will be heard This Remote Control will operate only after the inverter PST 3000 has been first turned ON using the local ON OFF Switch on the inverter or using external ON OFF control provided in the inverter Read under heading Optional ...

Страница 4: ...e Display Push Button 2 is pressed and will then switch OFF into Sleep Mode To wake up press the Display Push Button 2 4 32 5 32 5 65 110 OVER LOAD OVER TEMP POWER DISPLAY MODEL RC 300 Pure Sine Wave 8 5 15 8 5 15 48 Overall Depth 25 5 Front View Back View 1 1 1 2 3 4 5 6 7 R2 R2 32 5 32 5 4 32 5 32 5 98 80 LEGEND 1 Power ON OFF Push Button 2 Push Button to Change Display Screen 3 LCD Screen 4 LED...

Страница 5: ...2 3 4 5 6 7 8 9 10 Figure 2 Remote Control RC 300 Pintout of Modular Jack RJ 50 Fig 2 Remote Control RC 300 Pinout of Modular Jack RJ 50 The standard numbering system of the pins of a Modular Jack when looking into the Jack is from left to right As the conductors of the cable are cross connected rolled over the pinouts at the Modular Jack in the inverter will be a mirror image of the pinout of the...

Страница 6: ...FF control provided on the inverter for de tails please refer to Section 8 of Owner s Manual for PST 3000 12 PST 3000 24 under heading Optional Wired Remote Control Model RC 300 Once the inverter turns ON the operational status of the inverter will be displayed through the LCD screen 3 Fig 1 and LEDs 4 5 6 Fig 1 5 2 See under headings LCD Display Section 3 3 and 3 4 and LED Display Section 3 5 for...

Страница 7: ...e inverter to prevent unnecessary current drain from the battery SECTION 6 SPECIFICATIONS MODEL NUMBERS OF COMPATIBLE INVERTERS PST 3000 12 PST 3000 24 CABLE SET RJ 50 10P10C with crossed over rolled over connections Length 25 ft 7 62 meters OPERATING TEMPERATURE RANGE 0 to 40 C 32 F to 104 F DIMENSIONS L X W X D 110 x 65 x 24 7 mm 4 33 x 2 56 x 0 97 in Weight Without cable with cable 85 gm 256 gm...