TYPICAL INSTALLATION
• When using volatile cleaning products, the equipment
must be grounded thereby reducing the risk of static
and electric shocks and providing an escape route
for electrical current.
• For cleaning in closed areas, locate the pump
away from any storage tanks and provide adequate
ventilation.
• If flammable materials are placed in the cleaning
area, take appropriate precautions to avoid sparks.
AIR AND FLUID HOSES
• use only electrically conductive hoses
SPRAY GUN/DISPENSE VALVE
• Ground through connection to a properly grounded
fluid hose and pump
SOLVENT PAILS USED WHEN FLUSHING
• Use only metal pails
• Place the pail only on grounded surface
• Don't place the pail on a non-conductive surface, such
as paper or cardboard, which interrups grounding
continuity
GROUNDING PUMP
• Use supplied grounding wire (
1
) and clamp (
2
)
• Connect the other end of the wire to a true earth
ground (
3
)
GROUNDING
The figure (
1
) shows a typical installation with all the
recommended accessories for the pump to operate
correctly.
It is recommended to install an air supply shut-off valve
(to be closed at the end of the work).
MAINTAINING GROUNDING CONTINUITY DURING
FLUSHING OR PRESSURE RELIEF
• Firmly hold the metal part of the spray gun / dispense
valve on the side of a grounded metal pail, then
activate the spray gun / dispense valve
From customer
suplply air
From customer
supply product
Air regulation
filter
Air supply
shut-off valve
Material
outlet
Material
input
NOVA 10:1
11
ED.
01 - 09/2023 - Cod. 150209
IT
EN
I
Fig 1
J
Fig. 1