www.larius.com
41
V
24 mm*
9 mm**
2
1
zEus for sanitation
REV
. 01 - 05/2020 - Cod. 150125
DISCONNECT THE POWER SUPPLY BEFORE
CHECKING OR REPLACING THE BRUSHES.
ELECTRIC MOTOR
• Periodically check on the wear of the pinion (
at least every
1000 working hours
).
• Periodically check the perfect connection among all the
electrical components (
at least every 200 working hours
).
• The length of the brush contact must be higher than 9 mm
to guarantee a good working of the rotary group.
*Length of new brush
**Minimum length of the brush
Replace
Pos.
W
Descrizione
Q. tà
1
20280
Brush 220V 50Hz
4
1
20281
Brush 110V 60Hz
4
2
20282
Brush holder plug
4