background image

www.larius.com

15

L200 - L201

REV.

 01 - 01/2020 - Cod. 150084

FIRE OR EXPLOSION HAZARD

Static electricity is created by the flow of fluid through the pump 

and hose. If every part of the equipment is not properly grounded, 

sparking may occur, and the system may become hazardous.
Sparks may also occur when plugging in or unplugging a power 
supply cord. Sparks can ignite fumes from solvents and the fluid 
being dispensed, dust particles and other flammable substances, 
whether you are pumping indoors or outdoors, and cause a fire 
or explosion, serious injury, and property damage.

GROUNDING

To  reduce  the  risk  of  static  sparking,  ground  the  pump  and 
all  other  equipment  used  or  located  in  the  dispensing  area. 

 

Check your local electrical code for detailed grounding instructions 

for your area and type of equipment and be sure to ground all of 
the following equipment.

•  Pump: ground the pump by connecting a grounding wire from 

the pump’s grounding lug to a true earth ground.

•  Air compressor or hydraulic power supply: ground according to 

local code and manufacturer’s recommendations.

•  Fluid hoses: use only grounded hoses with a maximum of 150 

mt.  Combined  hose  length  to  ensure  grounding  continuity. 

 

Refer to hose grounding continuity, above.

•  Flo-gun:  obtain  grounding  through  connection  a  properly 

grounded fluid hose and pump.

•  Fluid supply container: according to local code.

•  All solvent pails used when flushing: according to local code. 

Use only metal pails. Do not place the pail on a non-conductive 
surface,  such  as  paper  or  cardboard,  which  interrupts  the 
grounding continuity.

Moving parts can pinch or amputate your fingers or other body 
parts.  Keep  clear  of  moving  parts  when  starting  or  operating 

your system. 

Before checking or servicing the gun, pump, or any other system 
component follow the PRESSURE DISCHARGING PROCEDURE 
to prevent the pump from starting accidentally.

Do not plug in or unplug any power supply cords 
in the dispensing area when there is any chance 
of igniting fumes still in the air.
If you experience any static sparking or feel even 
a slight shock while using this equipment, STOP 
DISPENSING IMMEDIATELY. Check for proper 
grounding of the entire system. Do not use the 
system again until the cause of the problem is 
identified and corrected.

Before flushing, be sure the entire system and 
flushing pails are properly grounded. Refer to 
GROUNDING, above. Always use the lowest 
possible fluid pressure, and maintain firm  
metal-to-metal contact between the gun and 
grounded metal pail during flushing to reduce 
the risk of fluid injection injury, static sparking 
and splashing. 

CONDITIONS OF GUARANTEE

N

The conditions of guarantee do not apply in the 

following situations:

- improper washing and cleaning of components 

causing malfunction, wear or damage to the 
equipment or any of its parts;

- improper use of the equipment;
- use that does not conform with applicable  

national legislation;

- incorrect or faulty installation;
-  modifications, interventions and maintenance  

that have not been authorised by the  
manufacturer;

- use of non-original spare parts or parts that do 

not correspond to the specific model;

- total or partial non-compliance with the  

instructions provided.

 

L

MOVING PARTS HAZARD

M

Содержание Larius L200

Страница 1: ...L200 INOX version ALLUMINIUM version L201 INOX version ALLUMINIUM version Automatic guns Air assisted airless w w w l a r i u s c o m REV 01 01 2020 Cod 150084 English OPERATING INSTRUCTIONS...

Страница 2: ...onal market The brand is distributed worldwide through an extensive network of distributors and resellers and is a guarantee of Total Product Quality in the industrial plastics construction wood and r...

Страница 3: ...CTION p 16 FLUID SYSTEM CONNECTION p 17 PNEUMATIC SYSTEM CONNECTION p 18 exploded view of the L200 L201 AUTOMATIC gun p 20 exploded view of the BLOCK WITH SIDE INLETS L200 p 22 exploded view of the BL...

Страница 4: ...t carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has not b...

Страница 5: ...an 2 base for Super Fast Clean or Top Spraying Clean nozzles www larius com 5 L200 L201 REV 01 01 2020 Cod 150084 B COD 21340 COD 21341 COD 21342 COD 21343 VERSIONS Code Description 21340 L200 Air ass...

Страница 6: ...inlet bases The two bases are completely interchangeable without having to make changes to the body of the spray gun rapid couplings to speed up the connection of the spray gun to the air supply line...

Страница 7: ...s steel alluminium carbide polyethylene chemically resistant fluoroelastomer PTFE Material in contact with fluid alluminium POM flluoroelastomer Guns weight L200 1100 g L200 Avional 770 g L201 1230 g...

Страница 8: ...www larius com 8 L200 L201 REV 01 01 2020 Cod 150084 D a ATEX CERTIFICATE...

Страница 9: ...www larius com 9 L200 L201 REV 01 01 2020 Cod 150084 E a DIMENSIONS AND OVERALL L200 GUN DIMENSIONS AND OVERALL E 60 30 43 112 142 30 15 27 5 10 4 8 X6 8 X6 8 X6 GJ 1 4 39 36 5 M4X10 73 45 81...

Страница 10: ...www larius com 10 L200 L201 REV 01 01 2020 Cod 150084 E b DIMENSIONS AND OVERALL L201 GUN 60 41 45 112 142 30 27 5 26 10 4 Gj 1 8 8 X6 8 X6 8 X6 45 85 5 39 25 28 M4X10...

Страница 11: ...VES OR AT OTHER PEOPLE THE CONTACT WITH THE CASTING CAN CAUSE SERIOUS INJURIES IN CASE OF INJURIES CAUSED BY THE GUN CASTING SEEK IMMEDIATE MEDICAL ADVICE SPECIFYING THE TYPE OF THE PRODUCT INJECTED N...

Страница 12: ...with which it can come into contact Never use paints or sol vents containing halogen hydrocarbons as the methylene chloride If these products come into contact with alu minium parts can provoke danger...

Страница 13: ...y gun L201 spray gun DESCRIPTION OF THE EQUIPMENT H Pos Description 1 Head 2 Locking ring nut 3 Gun body 4 Threaded cap for adjustment Pos Description 5 Air connections 6 Material in out 7 Air inlet b...

Страница 14: ...ktheresistance Iftheresistanceexceedstherecommended limits replaceitimmediately Anungroundedorpoorlygrounded fluid hose can make your system hazardous Be sure that all dispensing equipment and accesso...

Страница 15: ...r cardboard which interrupts the grounding continuity Moving parts can pinch or amputate your fingers or other body parts Keep clear of moving parts when starting or operating your system Before check...

Страница 16: ...built with different solutions LARIUS is at your disposal to help design custom solutions with different production requirements NOTE This diagram is merely indicative and has no contractual value Po...

Страница 17: ...www larius com 17 L200 L201 REV 01 01 2020 Cod 150084 ENTRY RIGHT ENTRy left Recirculation FLUID SYSTEM CONNECTION P FLUIDE FLUIDE FLUIDE FLUIDE...

Страница 18: ...www larius com 18 L200 L201 REV 01 01 2020 Cod 150084 PNEUMATIC SYSTEM CONNECTION Q L200 L201...

Страница 19: ...T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k www larius com 19 L200 L201 REV 01 01 2020 Cod 150084...

Страница 20: ...21 17 23 24 25 16 27 28 26 10 29 30 31 32 33 34 38 36 39 13 35 18 22 28 37 27 WARNING Always indicate code and quantity for each part required EXPLODED VIEW OF L200 L201 AUTOMATIC GUN R www larius co...

Страница 21: ...23306 Screw 3 14 21357 Ring 2 15 9287 Ring 1 16 4077 Ring 2 17 21317 Piston 1 18 11105 Ring 1 19 21355 Rod material 1 20 12525 Spring 1 21 21319 Rod plate 1 22 6127 Grub screw 1 23 11814 Spring 1 24...

Страница 22: ...indicate code and quantity for each part required Pos Code Description Q ty 1 4006 Quick coupling 2 2 11781 Quick coupling 1 3 21303 Air inlet block 1 4 8026 1 Grub screw 1 5 21304 Product inlet bloc...

Страница 23: ...Q ty 1 4006 Quick coupling 2 2 11781 Quick coupling 1 3 21305 Air inlet block 1 4 8026 1 Grub screw 1 5 21306 Product inlet block 1 5A 21306 1 Product inlet block Al anticorodal avional version 1 6 9...

Страница 24: ...1953 7 65 21954 9 20 21955 9 40 21956 9 65 21957 9 80 21958 11 25 21959 11 40 Code Measure 21960 11 60 21961 13 20 21962 13 40 21963 13 60 21965 15 25 21966 15 40 21967 15 60 21969 17 25 21970 17 40 C...

Страница 25: ...ar SFC 17 20 1 41 SFC 17 40 1 41 SFC 17 60 1 41 SFC 19 20 1 77 SFC 19 40 1 77 SFC 19 60 1 77 SFC 21 20 2 15 SFC 21 40 2 15 SFC 21 60 2 15 SFC 23 20 2 57 SFC 23 40 2 57 SFC 23 60 2 57 Measure Capacity...

Страница 26: ...llo sporco o intasato Clean or replace it Materialleaksfromthegasketpressing screw Gasket loosened or worn Tighten the gasket pressing screw or change the gasket Atomization imperfect Nozzle worn Repl...

Страница 27: ...T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k...

Страница 28: ...345 INOX Code 21340 AIR ASSISTED AIRLESS automatic gun L200 with side inlets complete with Mist Clean 2 base for Super Fast Clean or Top spraying Clean tip ALLUMINIUM Code 21344 INOX Code 21342 AIR AS...

Страница 29: ...ip Code 21801 Airless spraying gun AT250 complete with Super Fast Clean base Code 11200 Airless gun PLA cm 130 complete with Super Fast Clean base Code K11421 Automatic gun MA98L low pressure Code 113...

Страница 30: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com...

Отзывы: