The fluid in the feed hose may be extremely hazardous. If there is 
a leak from the hose or a cut or rupture due to wear or damage or 
incorrect use, the fluid that leaks out may cause fluid penetration 
damage or may seriously damage objects.

Any  misuse  of  the  dispensing  equipment  or  accessories, 

 

such as overpressurizing, modifying parts, using incompatible 
chemicals  and  fluids,  or  using  worn  or  damaged  parts,  can 
cause them to rupture and result in serious injury, including fluid 
injection and splashing fluid in the eyes or on the skin, or in fire, 

 

explosion or property damage.

•  Do not attempt to reconnect the feed hoses or repair them with 

tape or any other method.  

•  Handle and route hoses carefully.

MEDICAL ALERT – FLUID INJECTION WOUNDS

If any fluid appears to penetrate your skin, get EMERGENCY 

MEDICAL CARE AT ONCE. DO NOT TREAT AS A SIMPLE CUT.

Tell the doctor exactly what fluid was injected.

•  Tighten  all  fluid  connections  securely  before  each  use. 

 

High pressure fluid can dislodge a loose coupling or allow high 
pressure fluid to be emitted from the coupling

•  Never use a damaged hose. If any of these conditions exist, 

replace the hose immediately.

Proper hose grounding continuity is essential to maintaining a 
grounded dispensing system. Check the electrical resistance of 
your fluid hoses at least once a week. If your hose does not have 
a tag on it which specifies the maximum electrical resistance, 
contact  the  hose  supplier  or  manufacturer  for  the  maximum 
resistance limits.
Use a resistance meter in the appropriate range for your hose to
check the resistance. If the resistance exceeds the recommended 
limits, replace it immediately. An ungrounded or poorly grounded 
fluid hose can make your system hazardous.

Be  sure  that  all  dispensing  equipment  and  accessories  are 

 

properly rated to withstand the pressures developed by your 

system. Never exceed the maximum working pressure of your 

gun model.

J

The fluid that the spray gun shoot may penetrate the 
skin and body causing severe damage, including  
the need for amputation. Fluid that penetrates or 
is sprayed into the eyes or onto the skin can also 
cause serious injury.

Injection into the skin is a traumatic injury.  
It is important to treat the injury surgically as 
soon as possible. Do not delay treatment to 
research toxicity.
Toxicity is a concern with some exotic materials  
injected directly into the blood stream.  
Consultation with a plastic surgeon may be 
advisable.

EQUIPMENT MISUSE
HAZARD

The maximum working pressure of the gun is 
280 bar. Do not exceed the maximum Working 
pressure.

Do not place hands or fingers on the nozzle.
Do not clean the residues that form around the 
nozzle until the pressure has been completely 
discharged. Do not try and stop leaks with your 
hands or body.

Be sure all fluids and solvents used are chemically 
compatible with the “WETTED PARTS” shown in 
the TECHNICAL DATA. Always read the fluid and 
solvent manufacturer’s literature before using any 
fluid or solvents in your system.

FLUID INJECTION HAZARD

I

Before each use, check the entire hose for cuts, 
leaks, abrasion, bulging cover, or damage or 
movement of the hose couplings.

Do not pull on hoses to move equipment.
Do not use fluids or solvents which are not  
compatible with the inner tube and cover of the 
hose.
Do not expose hose to extreme temperatures; 
check with your hose supplier to determine 
temperature tolerance.

FLUID INJECTION HAZARD

Содержание Larius L200

Страница 1: ...L200 INOX version ALLUMINIUM version L201 INOX version ALLUMINIUM version Automatic guns Air assisted airless w w w l a r i u s c o m REV 01 01 2020 Cod 150084 English OPERATING INSTRUCTIONS...

Страница 2: ...onal market The brand is distributed worldwide through an extensive network of distributors and resellers and is a guarantee of Total Product Quality in the industrial plastics construction wood and r...

Страница 3: ...CTION p 16 FLUID SYSTEM CONNECTION p 17 PNEUMATIC SYSTEM CONNECTION p 18 exploded view of the L200 L201 AUTOMATIC gun p 20 exploded view of the BLOCK WITH SIDE INLETS L200 p 22 exploded view of the BL...

Страница 4: ...t carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has not b...

Страница 5: ...an 2 base for Super Fast Clean or Top Spraying Clean nozzles www larius com 5 L200 L201 REV 01 01 2020 Cod 150084 B COD 21340 COD 21341 COD 21342 COD 21343 VERSIONS Code Description 21340 L200 Air ass...

Страница 6: ...inlet bases The two bases are completely interchangeable without having to make changes to the body of the spray gun rapid couplings to speed up the connection of the spray gun to the air supply line...

Страница 7: ...s steel alluminium carbide polyethylene chemically resistant fluoroelastomer PTFE Material in contact with fluid alluminium POM flluoroelastomer Guns weight L200 1100 g L200 Avional 770 g L201 1230 g...

Страница 8: ...www larius com 8 L200 L201 REV 01 01 2020 Cod 150084 D a ATEX CERTIFICATE...

Страница 9: ...www larius com 9 L200 L201 REV 01 01 2020 Cod 150084 E a DIMENSIONS AND OVERALL L200 GUN DIMENSIONS AND OVERALL E 60 30 43 112 142 30 15 27 5 10 4 8 X6 8 X6 8 X6 GJ 1 4 39 36 5 M4X10 73 45 81...

Страница 10: ...www larius com 10 L200 L201 REV 01 01 2020 Cod 150084 E b DIMENSIONS AND OVERALL L201 GUN 60 41 45 112 142 30 27 5 26 10 4 Gj 1 8 8 X6 8 X6 8 X6 45 85 5 39 25 28 M4X10...

Страница 11: ...VES OR AT OTHER PEOPLE THE CONTACT WITH THE CASTING CAN CAUSE SERIOUS INJURIES IN CASE OF INJURIES CAUSED BY THE GUN CASTING SEEK IMMEDIATE MEDICAL ADVICE SPECIFYING THE TYPE OF THE PRODUCT INJECTED N...

Страница 12: ...with which it can come into contact Never use paints or sol vents containing halogen hydrocarbons as the methylene chloride If these products come into contact with alu minium parts can provoke danger...

Страница 13: ...y gun L201 spray gun DESCRIPTION OF THE EQUIPMENT H Pos Description 1 Head 2 Locking ring nut 3 Gun body 4 Threaded cap for adjustment Pos Description 5 Air connections 6 Material in out 7 Air inlet b...

Страница 14: ...ktheresistance Iftheresistanceexceedstherecommended limits replaceitimmediately Anungroundedorpoorlygrounded fluid hose can make your system hazardous Be sure that all dispensing equipment and accesso...

Страница 15: ...r cardboard which interrupts the grounding continuity Moving parts can pinch or amputate your fingers or other body parts Keep clear of moving parts when starting or operating your system Before check...

Страница 16: ...built with different solutions LARIUS is at your disposal to help design custom solutions with different production requirements NOTE This diagram is merely indicative and has no contractual value Po...

Страница 17: ...www larius com 17 L200 L201 REV 01 01 2020 Cod 150084 ENTRY RIGHT ENTRy left Recirculation FLUID SYSTEM CONNECTION P FLUIDE FLUIDE FLUIDE FLUIDE...

Страница 18: ...www larius com 18 L200 L201 REV 01 01 2020 Cod 150084 PNEUMATIC SYSTEM CONNECTION Q L200 L201...

Страница 19: ...T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k www larius com 19 L200 L201 REV 01 01 2020 Cod 150084...

Страница 20: ...21 17 23 24 25 16 27 28 26 10 29 30 31 32 33 34 38 36 39 13 35 18 22 28 37 27 WARNING Always indicate code and quantity for each part required EXPLODED VIEW OF L200 L201 AUTOMATIC GUN R www larius co...

Страница 21: ...23306 Screw 3 14 21357 Ring 2 15 9287 Ring 1 16 4077 Ring 2 17 21317 Piston 1 18 11105 Ring 1 19 21355 Rod material 1 20 12525 Spring 1 21 21319 Rod plate 1 22 6127 Grub screw 1 23 11814 Spring 1 24...

Страница 22: ...indicate code and quantity for each part required Pos Code Description Q ty 1 4006 Quick coupling 2 2 11781 Quick coupling 1 3 21303 Air inlet block 1 4 8026 1 Grub screw 1 5 21304 Product inlet bloc...

Страница 23: ...Q ty 1 4006 Quick coupling 2 2 11781 Quick coupling 1 3 21305 Air inlet block 1 4 8026 1 Grub screw 1 5 21306 Product inlet block 1 5A 21306 1 Product inlet block Al anticorodal avional version 1 6 9...

Страница 24: ...1953 7 65 21954 9 20 21955 9 40 21956 9 65 21957 9 80 21958 11 25 21959 11 40 Code Measure 21960 11 60 21961 13 20 21962 13 40 21963 13 60 21965 15 25 21966 15 40 21967 15 60 21969 17 25 21970 17 40 C...

Страница 25: ...ar SFC 17 20 1 41 SFC 17 40 1 41 SFC 17 60 1 41 SFC 19 20 1 77 SFC 19 40 1 77 SFC 19 60 1 77 SFC 21 20 2 15 SFC 21 40 2 15 SFC 21 60 2 15 SFC 23 20 2 57 SFC 23 40 2 57 SFC 23 60 2 57 Measure Capacity...

Страница 26: ...llo sporco o intasato Clean or replace it Materialleaksfromthegasketpressing screw Gasket loosened or worn Tighten the gasket pressing screw or change the gasket Atomization imperfect Nozzle worn Repl...

Страница 27: ...T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k...

Страница 28: ...345 INOX Code 21340 AIR ASSISTED AIRLESS automatic gun L200 with side inlets complete with Mist Clean 2 base for Super Fast Clean or Top spraying Clean tip ALLUMINIUM Code 21344 INOX Code 21342 AIR AS...

Страница 29: ...ip Code 21801 Airless spraying gun AT250 complete with Super Fast Clean base Code 11200 Airless gun PLA cm 130 complete with Super Fast Clean base Code K11421 Automatic gun MA98L low pressure Code 113...

Страница 30: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com...

Отзывы: