background image

3

1

IMPORTANT SAFETY INSTRUCTIONS

 

THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION, 

MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USE, READ AND UNDERSTAND ALL 

CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT LABELS, PLUS YOUR VEHICLE’S BATTERY 

MANUFACTURER GUIDELINES. FAILURE TO DO SO COULD RESULT IN INJURY AND/OR PROPERTY 

DAMAGE.

To ensure reliable service, your power inverter must be installed and used properly. Please read the installation 

and operating instructions thoroughly prior to installation and use. Pay particular attention to the WARNING 

and CAUTION statements in this manual. The CAUTION statements advise against certain conditions and 

practices that may result in damage to your inverter. The WARNING statements identify conditions or practices 

that may result in personal injury.  Read All Instructions Before Using This Power Inverter!

WARNINGS 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION OR INJURY

1.  Do not connect to AC distribution wiring. This inverter is NOT grid interactive.
2.  Remove appliance plug from outlet strip or turn off inverter before working on the appliance. Multiple 

outlet power strips with switches and circuit breakers only interrupt power to the “hot” receptacle 

terminals. 

For SSW-350-12A & SSW-600-12A, the “Neutral” terminals remain powered with respect to 

the “Ground” terminals.

3.  Do not make any electrical connections or disconnections in areas designated as IGNITION PROTECTED. 

This includes 12 V DC cigarette plug connections, and terminal connections.

4.  This is not a toy - keep away from children.
5.  DO NOT install object into air vents.

CAUTIONS  

1.  The chassis and the input Negative terminal of the inverter are internally connected to the AC Ground. 

Hence, the input Negative terminal should be used as the grounding terminal.

 Do not use with Positive 

Grounded Electrical Systems (the majority of modern automobiles, RVs, trucks and boats are Negative 

Grounded Electrical Systems). 

2.  Observe correct polarity when connecting the DC input terminals of the inverter to the battery. Connect 

Positive of the battery to the Positive input connector of the inverter and the Negative of the battery to 

the Negative input terminal of the inverter. 

Reverse polarity connection will result in a blown fuse and 

may cause permanent damage to the inverter. Damage due to reverse polarity is not covered under 

warranty.

3.  This inverter will not operate high wattage appliances that exceed the output power limit or the surge 

power limit.

4.  For SSW-350-12A & SSW-600-12A, grounding the Neutral will cause the inverter to shut down. Hence, 

do not connect the Neutral of the AC output receptacles to Ground.

5.  Do not operate this inverter if it is wet. 
6.  Do not install in engine compartment – please install in a well ventilated area.
7.  This inverter is not tested for use with medical devices.

Содержание SSW-350-12A

Страница 1: ...Owner s Manual Please read this manual before operating your inverter Pure Sine Wave Power Inverter SSW 350 12A SSW 600 12A SSW 1000 12A SSW 1500 12A SSW 2000 12A...

Страница 2: ...ctions 3 2 How Your Inverter Works 5 3 Installation Environments 6 4 Operating Tips 10 5 Protective Features of the Inverter 12 6 Special Features 13 7 Troubleshooting Guide 14 8 Fuse Replacement 16 9...

Страница 3: ...t to the Ground terminals 3 Do not make any electrical connections or disconnections in areas designated as IGNITION PROTECTED This includes 12 V DC cigarette plug connections and terminal connections...

Страница 4: ...higher voltage drop Similarly thicker and shorter wire has lower resistance and hence produces lower voltage drop Hence symptoms of low DC input voltage battery power can result from wires that are ei...

Страница 5: ...ge is a DC to DC conversion process that raises the low voltage DC at the inverter input to high voltage DC of approximately 150 VDC The second stage is the actual inverter stage that converts the hig...

Страница 6: ...r source must provide between 11 0 and 15 0 VDC and the required current This DC power source must be a well regulated DC power supply or alternator and deep cycle battery system typically found in ve...

Страница 7: ...heck to make sure you have not reversed the polarity Reverse polarity connection will result in a blown fuse and may cause permanent damage to the inverter Damage due to reverse polarity is not covere...

Страница 8: ...crimped soldered at the bare ends of the wires for secure connections 2 Ensure that the inverter s power switch is turned off and that no flammable fumes are present 3 Identify the Positive and Negati...

Страница 9: ...as the ground car floor or other solid surface The power cord allows easy positioning of the inverter The inverter should only be used in locations that meet the following criteria DRY Do not allow w...

Страница 10: ...switch ON again SIZING CHART FOR TYPICAL LOADS THAT REQUIRE HIGH STARTING SURGE The manufacturers specifications of the appliances and devices indicate only the running power required The surge power...

Страница 11: ...be used 5 Divide the total Watt Hours of energy on the AC side by 10 to get the total Ampere Hour of energy on the 12 VDC side to support the operation of the appliances 6 The Ampere Hour AH capacity...

Страница 12: ...al occurs the protection circuit activates and shuts down the inverter which prevents electric shock to humans Turn OFF the inverter unplug the fault AC appliance and then turn ON is the only way to r...

Страница 13: ...ES 1000W NO YES YES YES YES 1500W NO YES YES YES YES 2000W NO YES YES YES YES 1 Standard USB charging port 5 VDC 500mA 2 Compatible with specific SAMLEX SSW series remote control only Connection with...

Страница 14: ...nd Green LEDs are not lit No audible alarm Inverter has shut down due to overload In Models SSW 350 and SSW 600 this shut down could also be due to ground fault on the load side These models have buil...

Страница 15: ...e voltage drop due to thinner wires or loose connections in the DC input circuit Recharge the battery Use thicker DC input wires and tighten all DC input circuit connections AC output is available Aud...

Страница 16: ...that this inverter is equipped with a DC side fuses that are located inside the inverter Normally these fuses will not blow unless a serious problem occurs Please DO NOT replace the fuses yourself We...

Страница 17: ...CTOR NO NO YES YES YES PROTECTIONS LOW INPUT VOLTAGE WARNING ALARM 11 0 VDC LOW INPUT VOLTAGE SHUTDOWN 10 5 VDC HIGH INPUT VOLTAGE SHUTDOWN 15 3 VDC OVERLOAD SHUTDOWN YES COOLING LOAD CONTROLLED FAN Y...

Страница 18: ...pt to remedy the defect by anyone other than the Warrantor shall render this warranty void There shall be no warranty for defects or damages caused by faulty installation or hook up abuse or misuse of...

Страница 19: ...110 17 Fawcett Rd Coquitlam BC Canada V3K 6V2 T 604 525 3836 F 604 525 5221 1 800 561 5885 e mail samlex samlexamerica com website www samlexamerica com SSW_Series_Inverters_Manual_Dec2010_1 0 1...

Отзывы: