Connect the cable to the appropriate port of the communication PWB in the unit.
Connect the other end of the cable to the appropriate port of the PC.
Make sure the conduit fitting or cable grand on the knockout is sealed and safe from rain
Replacing the cover
After AC, DC and Communication wires are all connected, make sure the Isolation sheet
with cautionary markings covers over the power circuitry below and no pressure will be
exerted on any connections when the cover is fixed.
Position the cover on the Soleil 2000 carefully and align the four holes on the cover to the
threaded holes of the brass threaded spacers on the enclosure.
Carefully insert the four screws previously removed to take the cover off through the
nylon washers and the aligned holes and fasten them till they are finger-tight.
After verifying that the front cover is in correct position and the seal well in place, fasten
all screws till firmly tight.
Warning :
Never install the Soleil 2000 during rainy day. Moisture
trapped inside the enclosure during those very damp conditions would
damage the sensitive electronic components.