background image

LOAD AND BATTERY CONNECTIONS 

 

THE LOAD & BATTERY TERMINALS ON THE POWER SUPPLY HAVE A TUBU-
LAR HOLE OF DIAMETER 8mm (0.31”) WITH A SET SCREW. 
 
ALWAYS ENSURE THAT THE CONNECTIONS ARE SECURE AND THE SCREWS 
ARE TIGHTENED PROPERLY.  

 
LOOSELY TIGHTENED CONNECTIONS RESULT IN EXCESSIVE VOLTAGE 
DROP AND MAY CAUSE OVERHEATED WIRES AND MELTED INSULATION. 

 

THE ENDS OF THE CABLES TO BE CONNECTED TO THE LOAD AND BATTERY 
TERMINALS ON THE POWER SUPPLY SHOULD HAVE PIN TYPE OF CONNEC-
TOR FOR MAKING A FIRM CONNCECTON. 

4 PIECES OF PIN TYPE CONNEC-

TORS ARE ENCLOSED WITH THE POWER SUPPLY. CRIMP THESE TO THE 
ENDS OF THE CABLES. 
 

USE MULTI STRANDED WELDING TYPE CABLE OR BATTERY CABLE
(NEOPRENE SYNTHETIC INSULATION, 90

o

C). USE PROPER SIZE OF CABLE, 

AS INDICATED BELOW,  TO CONNECT ANY DEVICE TO THE POWER SUPPLY. 
THESE CABLE SIZES ARE VALID WHEN THE DEVICE  IS WITHIN  6 FT. DIS-
TANCE FROM THE POWER SUPPLY. 

THICKER WIRING WILL BE REQUIRED 

FOR LONGER DISTANCES. THINNER WIRES WILL CAUSE OVERHEATING 
AND EXCESSIVE VOLTAGE DROP : 

  

SEC-100BRM-220 

 

   100 A   

# 2 AWG |   UP TO 

SEC-80BRM-220  

 

   80 A   

# 4 AWG |   6’  

SEC-60BRM/SEC-40BRM-220 

    UP TO 60 A 

# 6 AWG |   DISTANCE 

 

 

 

 

 

ENSURE THAT THE AC POWER IS SWITCHED OFF WHEN ANY DEVICE IS BE-
ING CONNECTED TO THE POWER SUPPLY.  
 
DO NOT ALLOW THE ENDS OF THE POSITIVE AND NEGATIVE  WIRES TO 
TOUCH EACH OTHER. 

 

FUSE REPLACEMENT

 

 

ENSURE PROPERLY RATED FUSE ( 250 V, 4A ) IS USED IN EACH OF THE 
MODULES. 

 

ENVIRONMENT 

 
DO NOT EXPOSE POWER SUPPLY TO RAIN, SNOW OR WATER SPRAY 

 

DIS-ASSEMBLY AND REPAIR 

 

THE POWER SUPPLY SHOULD BE DISASSEMBLED OR REPAIRED BY A 
QUALIFIED TECHNICIAN. INCORRECT REASSEMBLY OR REPAIR MAY  RE-
SULT  IN A  RISK OF ELECTRIC SHOCK  OR FIRE  WHICH MAY RESULT IN 
PERSONAL INJURY AND PROPERTY DAMAGE

 

2. 

Содержание SEC-40BRM-220

Страница 1: ...0BRM 220 SEC 80BRM 220 SEC 100BRM 220 Please read this manual before operating your power supply INSTALLATION OPERATING MANUAL EXPANDABLE DC POWER SUPPLY 230V AC INPUT N 1 DC Power System with Battery...

Страница 2: ...RIES FOR BACKUP EXPAND OUTPUT POWER BY ADDING POWER MODULES UP TO 100 AMPS CONTINUOUS POWER VOLT AMPERE METER OPERATION STATUS L E D FAN FAILURE ALARM AND WARNING L E D REMOTE MONITORING AND INDICATIO...

Страница 3: ...re 3 Front panel controls and indicators 4 Rear panel controls 4 5 Protections 5 Installation and operation 6 Operation of battery back up 7 Output voltage adjustment 8 9 Installation and removal of m...

Страница 4: ...2 POLE 2 WIRE RECEPTACLE THAT HAS NO GROUNDING REPLACEMENT OF POWER CORD PLUG THE POWER CORD IS PROVIDED WITH A MOULDED STANDARD EUROPEAN 2 POLE 3 WIRE GROUNDING PLUG SCHUKO 250V 16A THE PLUG MAY BE R...

Страница 5: ...ELOW TO CONNECT ANY DEVICE TO THE POWER SUPPLY THESE CABLE SIZES ARE VALID WHEN THE DEVICE IS WITHIN 6 FT DIS TANCE FROM THE POWER SUPPLY THICKER WIRING WILL BE REQUIRED FOR LONGER DISTANCES THINNER W...

Страница 6: ...PSM is required to be interconnected with one another to a common SHARE BUS through a pair of parallel pins marked JUMP 1 and jumper wires Fig 1 and 2 For proper operation of the current share control...

Страница 7: ...CH The rocker switch will illuminate when switched on 1B BREAKER A circuit breaker provides protection on the input side against overload 2 VOLTMETER AMMETER A combined voltmeter and ammeter are provi...

Страница 8: ...omatically once the short circuit condition is removed CURRENT LIMITING The unit will enter this mode when the load tries to draw more than the limiting values of currents as shown in the specificatio...

Страница 9: ...n the unit by pressing the power on off switch to on position The switch will be illuminated confirming that input power is available 8 A short beep may be generated by the temperature fault alarm cir...

Страница 10: ...D will be as follows At no external load Approx 14V At 10 A load Approx 13 8V At loads 10A Approx 13 8V minus 5mV per Amp above 10A THE BATTERY SHOULD BE LOCATED IN A WELL VEN TILATED AREA TO SAFELY D...

Страница 11: ...utput voltage of the module The adjustment range is 13 8 V to 14 6 V For the forced current share control to work properly it is important that the output voltage of each module connected in parallel...

Страница 12: ...C connectors for PSM 2 and connect them to PSM 2 Now only PSM 2 can energize Switch on the power supply Only PSM No 2 will operate Adjust the output voltage of this module to the desired value with th...

Страница 13: ...ector Connection to the opto coupler PCB and on ward to the D Sub connector for remote indication is made using color coded pair of wires for each of the 5 modules Please see the colour code for PSM 1...

Страница 14: ...RE THAT THERE IS NO BREAK IN THE SHARE BUS DAISY CHAIN AND THAT ALL THE JUMP1 TERMINALS ARE INTERCONNECTED 6 The module can now be removed TROUBLE SHOOTING POWER ON OFF SWITCH DOES NOT LIGHT WHEN SWIT...

Страница 15: ...n LED would extinguish or flash Reduce the load drawn to a value less than the combined maximum rated output of the working modules If the voltage does not rise to the rated voltage of 13 65 V to 13 3...

Страница 16: ...io Filters are used to limit the noise to acceptable level 3 Switching power supplies are also recipients of radio interference The nor mal operation of the power supply can be disturbed due to RF noi...

Страница 17: ...outlet circuits receptacles In such cases disconnect devices connected to the other AC outlet circuits receptacles served by this GFCI 6 Following additional guidelines may be followed to reduce the...

Страница 18: ...the earth ground through the earth ground pin of the AC power outlet receptacle Avoid connecting referencing the DC negative output terminal of the power supply to the earth ground e Connect a 1 4 wav...

Страница 19: ...T LIMIT 48A 72A 96A 120A OUTPUT RIPPLE PEAK TO PEAK 150mV OUTPUT NOISE PEAK TO PEAK 1V 0 9V 0 8V 0 7V COOLING FORCED AIR 2 FANS OPERATING TEMPERATURE 0 TO 40 C PROTECTIONS SHORT CIRCUIT YES CURRENT LI...

Страница 20: ...e and Negative output BUS Bars L N L line and N neutral terminals for 120V 60 Hz input power supply wires LED 1 Terminal for ON status for opto isolated remote indication LED 2 Terminal for LED PSM st...

Страница 21: ...socket for the missing sandwiched module s should be shorted by inserting a shorting link to pre vent a break in the daisy chain Fig 3 Jump 1 Jump 1 Jump 1 Jump 1 Jump 1 1 Female socket terminal of t...

Страница 22: ...y the Warrantor Any attempt to remedy the defect by anyone other than the Warrantor shall render this warranty void There shall be no warranty for defects or damages caused by faulty installation or h...

Страница 23: ...Attach copy of receipt here for your records Date purchased Additional notes Purchased from 20...

Страница 24: ...Thank you for purchasing a Samlex power supply product Samlex America Inc 110 17 Fawcett Road Coquitlam B C V3K 6V2 Canada SEC 40 60 80 100BRM _230_Feb2008...

Отзывы: