background image

2 YEAR Limited Warranty 

 

 

This product  manufactured by Samlex America, Inc. (the “Warrantor”) is warranted to be free 
from defects in workmanship and materials under normal use and service.  This warranty is in 
effect for 2 years from the date of purchase by the user (the “Purchaser”) 
 
 If the defective product is within the warranty period, the Purchaser should contact the place of 
purchase to obtain a Return Authorization Number. 
 
 The defective part or unit should be returned at the Purchaser’s expense to the authorized 
location. A written statement describing the nature of the defect, the date of purchase, the place 
of purchase, and the Purchaser’s name, address and telephone number should also be in-
cluded. 
 
 If upon the Warrantor’s examination, the defect proves to be the result of defective material or 
workmanship, the equipment will be repaired or replaced at the Warrantor’s option without 
charge, and returned to the Purchaser at the Warrantor’s expense if within the warranty period. 
 
 No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is un-
able to remedy the defect after having a reasonable number of opportunities to do so. 
 
 Warranty service shall be performed only by the Warrantor.  Any attempt to remedy the defect 
by anyone other than the Warrantor shall render this warranty void. 
 
 There shall be no warranty for defects or damages caused by faulty installation or hook-up, 
abuse or misuse of the equipment including exposure to excessive heat, salt or fresh water 
spray, or water immersion. 
 
 No other express warranty is hereby given and there are no warranties which extend beyond 
those described herein.  This warranty is expressly in lieu of any other expressed or implied 
warranties, including any implied warranty of merchantability, fitness for the ordinary purposes 
for which such goods are used, or fitness for a particular purpose, or any other obligations on 
the part of the Warrantor or its employees and representatives. 
 
 There shall be no responsibility or liability whatsoever on the part of the Warrantor or its em-
ployees and representatives for injury to any persons, or damage to person or persons, or dam-
age to property, or loss of income or profit, or any other consequential or resulting damage 
which may be claimed to have been incurred through the use or sale of the equipment, includ-
ing any possible failure of malfunction of the equipment, or part thereof. 
 
 The Warrantor assumes no liability for incidental or consequential damages of any kind. 
 
  
  
   
  
  
  
Samlex America Inc. (the “Warrantor”) 
110-17 Fawcett Road 
Coquitlam BC V3K6V2 Canada 
(800) 561-5885 
(604) 525-3836 
 
 
 
 

 

19. 

Содержание SEC-40BRM-220

Страница 1: ...0BRM 220 SEC 80BRM 220 SEC 100BRM 220 Please read this manual before operating your power supply INSTALLATION OPERATING MANUAL EXPANDABLE DC POWER SUPPLY 230V AC INPUT N 1 DC Power System with Battery...

Страница 2: ...RIES FOR BACKUP EXPAND OUTPUT POWER BY ADDING POWER MODULES UP TO 100 AMPS CONTINUOUS POWER VOLT AMPERE METER OPERATION STATUS L E D FAN FAILURE ALARM AND WARNING L E D REMOTE MONITORING AND INDICATIO...

Страница 3: ...re 3 Front panel controls and indicators 4 Rear panel controls 4 5 Protections 5 Installation and operation 6 Operation of battery back up 7 Output voltage adjustment 8 9 Installation and removal of m...

Страница 4: ...2 POLE 2 WIRE RECEPTACLE THAT HAS NO GROUNDING REPLACEMENT OF POWER CORD PLUG THE POWER CORD IS PROVIDED WITH A MOULDED STANDARD EUROPEAN 2 POLE 3 WIRE GROUNDING PLUG SCHUKO 250V 16A THE PLUG MAY BE R...

Страница 5: ...ELOW TO CONNECT ANY DEVICE TO THE POWER SUPPLY THESE CABLE SIZES ARE VALID WHEN THE DEVICE IS WITHIN 6 FT DIS TANCE FROM THE POWER SUPPLY THICKER WIRING WILL BE REQUIRED FOR LONGER DISTANCES THINNER W...

Страница 6: ...PSM is required to be interconnected with one another to a common SHARE BUS through a pair of parallel pins marked JUMP 1 and jumper wires Fig 1 and 2 For proper operation of the current share control...

Страница 7: ...CH The rocker switch will illuminate when switched on 1B BREAKER A circuit breaker provides protection on the input side against overload 2 VOLTMETER AMMETER A combined voltmeter and ammeter are provi...

Страница 8: ...omatically once the short circuit condition is removed CURRENT LIMITING The unit will enter this mode when the load tries to draw more than the limiting values of currents as shown in the specificatio...

Страница 9: ...n the unit by pressing the power on off switch to on position The switch will be illuminated confirming that input power is available 8 A short beep may be generated by the temperature fault alarm cir...

Страница 10: ...D will be as follows At no external load Approx 14V At 10 A load Approx 13 8V At loads 10A Approx 13 8V minus 5mV per Amp above 10A THE BATTERY SHOULD BE LOCATED IN A WELL VEN TILATED AREA TO SAFELY D...

Страница 11: ...utput voltage of the module The adjustment range is 13 8 V to 14 6 V For the forced current share control to work properly it is important that the output voltage of each module connected in parallel...

Страница 12: ...C connectors for PSM 2 and connect them to PSM 2 Now only PSM 2 can energize Switch on the power supply Only PSM No 2 will operate Adjust the output voltage of this module to the desired value with th...

Страница 13: ...ector Connection to the opto coupler PCB and on ward to the D Sub connector for remote indication is made using color coded pair of wires for each of the 5 modules Please see the colour code for PSM 1...

Страница 14: ...RE THAT THERE IS NO BREAK IN THE SHARE BUS DAISY CHAIN AND THAT ALL THE JUMP1 TERMINALS ARE INTERCONNECTED 6 The module can now be removed TROUBLE SHOOTING POWER ON OFF SWITCH DOES NOT LIGHT WHEN SWIT...

Страница 15: ...n LED would extinguish or flash Reduce the load drawn to a value less than the combined maximum rated output of the working modules If the voltage does not rise to the rated voltage of 13 65 V to 13 3...

Страница 16: ...io Filters are used to limit the noise to acceptable level 3 Switching power supplies are also recipients of radio interference The nor mal operation of the power supply can be disturbed due to RF noi...

Страница 17: ...outlet circuits receptacles In such cases disconnect devices connected to the other AC outlet circuits receptacles served by this GFCI 6 Following additional guidelines may be followed to reduce the...

Страница 18: ...the earth ground through the earth ground pin of the AC power outlet receptacle Avoid connecting referencing the DC negative output terminal of the power supply to the earth ground e Connect a 1 4 wav...

Страница 19: ...T LIMIT 48A 72A 96A 120A OUTPUT RIPPLE PEAK TO PEAK 150mV OUTPUT NOISE PEAK TO PEAK 1V 0 9V 0 8V 0 7V COOLING FORCED AIR 2 FANS OPERATING TEMPERATURE 0 TO 40 C PROTECTIONS SHORT CIRCUIT YES CURRENT LI...

Страница 20: ...e and Negative output BUS Bars L N L line and N neutral terminals for 120V 60 Hz input power supply wires LED 1 Terminal for ON status for opto isolated remote indication LED 2 Terminal for LED PSM st...

Страница 21: ...socket for the missing sandwiched module s should be shorted by inserting a shorting link to pre vent a break in the daisy chain Fig 3 Jump 1 Jump 1 Jump 1 Jump 1 Jump 1 1 Female socket terminal of t...

Страница 22: ...y the Warrantor Any attempt to remedy the defect by anyone other than the Warrantor shall render this warranty void There shall be no warranty for defects or damages caused by faulty installation or h...

Страница 23: ...Attach copy of receipt here for your records Date purchased Additional notes Purchased from 20...

Страница 24: ...Thank you for purchasing a Samlex power supply product Samlex America Inc 110 17 Fawcett Road Coquitlam B C V3K 6V2 Canada SEC 40 60 80 100BRM _230_Feb2008...