30 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 31
SECTION 11 |
Spécificités
Model No.
SEC-1250UL
INPUT
Input Voltage and Frequency
120VAC, 50/60 Hz (Default)
(108 to 132VAC)
230 VAC, 50/60Hz (By internal Jumper setting)
(207 to 253VAC)
Input Current
At 120VAC
10.4A
At 230VAC
5.6A
AC Input Connection
Attached Power Cord
6 ft length
3 x AWG#16 wire size
NEMA5-15P Plug
OUTPUT
Bulk Stage Current
Full Power Bulk Stage
Current (Default)
50A
Half Power Bulk Stage
Current (Selected by
Switch):
25 ±1A
Charging Voltages
Bulk Stage
13.5± 0.05VDC
Absorption, Level 1
13.5± 0.05VDC
Absorption, Level 2
14.4 ± 0.05VDC (Default)
14.0 ± 0.05VDC (By DIP
Switch setting)
Float Stage
13.5± 0.05VDC
No. of Charging Banks
2
Maximum Battery Capacity
500Ah
Output Connections
Tubular Hole with Set Screw
Hole Diameter
7.9 mm ; 5/16 in
Set screw size
5/16” x 24TPI
CHARGING PROFILES
Charging Stages
3 Stages (Default) :
• Bulk, Absorption and Float
• Timed Absorption Stage
o 4 Hours (Default)
o 8 Hours (By DIP Switch setting)
2 Stages (By DIP Switch setting):
• Bulk and Float
Threshold of Current for
Change Over
From Float to Absorption
Level 1
10±1A
From Absorption Level 2
to Float
5±0.5A
Battery Temperature
Compensation
Battery Temperature Sensor Model TF-500 (included)
Temperature Coefficient
-28 mV/°C
MONITORING
LED Display
Green LED indicates “Half Power Mode” is selected
Analogue Meters
Voltmeter
0 to 15V
Ammeter
0 to 50A
REMOTE CONTROL (Optional)
Remote Control & Remote
Control Port
RJ-45 (8P8C) Modular Port
Optional Remote Control Model 900-RC
(comes with 10M cable)