background image

 

 

 

 

SA-1500 Series 

Pure Sine Wave Inverter 

User’s Manual 

 

                                   

            

            

Содержание SA-1500 Series

Страница 1: ...3 SA 1500 Series Pure Sine Wave Inverter User s Manual...

Страница 2: ...nel operations 8 9 3 3 Installation 9 3 4 Quick hook up and testing 10 3 5 AC safety grounding 11 12 3 6 Making DC wiring connections 13 3 7 Inverter operation 14 15 3 8 Power output 16 4 Troubleshoot...

Страница 3: ...his includes any space containing gasoline powered machinery fuel tanks or joints fittings or other connection between components of the fuel system 1 2 Precautions When Working with Batteries 1 2 1 I...

Страница 4: ...ion 2 1 1 Power tools circular saws drills grinders sanders buffers weed and hedge trimmers air compressors 2 1 2 Office equipment computers printers monitors facsimile machines scanner 2 1 3 Househol...

Страница 5: ...ge Regulation 10 16 VDC 20 32 VDC Protection Overload Short Circuit Reverse Polarity Fuse Over Under Input Voltage Over Temperature Power Saving Recovery Time 5 Second Interface Control Port RS 232C W...

Страница 6: ...4...

Страница 7: ...ON OFF switch leave in the OFF position during installation 3 1 3 Battery Voltage indicator The battery voltage bar graph indicates the voltage at the input terminals of the power inverter At low inpu...

Страница 8: ...ts input voltage fell below 12 24 VDC 3 1 7 OTP Over Temperature Protection indicator The over temp indicator indicates that the power inverter has shut itself down because its temp has become overhea...

Страница 9: ...7 North America GFCI North America NEMA 5 15R Continental European SCHUKO Australia New Zealand United Kingdom Universal...

Страница 10: ...4 V battery or the other power sources is positive is negative Reverse polarity connection will blow internal fuse and may damage inverter permanently Model voltage Min voltage Max voltage SA 1500 112...

Страница 11: ...AWG wire 3 3 Protection Feature Model DC Input Over Temperature Protection Over voltage Under Voltage Alarm Under Voltage Shut down Restart Shut down Restart Shut down Restart SA 1500 112 17 1VDC 15 8...

Страница 12: ...5 Dust free Do not install the Inverter in a dusty environments where are dust wood particles or other filings shavings These dust can be pulled into the unit when the cooling fan is operating 3 4 6...

Страница 13: ...nverter performances such as poor surge capability and low input voltage warnings frequently and shutdowns UVP warning presents due to DC voltage drop across the cables from the inverter to the batter...

Страница 14: ...12 Also use only high quality copper wiring and keep cable length short a maximum of 3 6 feet...

Страница 15: ...ance with UL standards requires us to test and recommend specific GFCI Samlex has tested the following GFCI protected 20A receptacles and found that they functioned properly when connected to the outp...

Страница 16: ...f power inverter The terminal is positive and black terminal is negative Insert the cables into the terminals and tighten allen nut to clamp the wires securely 3 7 3 Before proceeding further carefull...

Страница 17: ...nternal alarm may sound momentarily This is normal Plug the test load into the AC receptacle on the front panel of the inverter Leave the test load switch off 3 7 7 Set power inverter switch to the ON...

Страница 18: ...operate small microwave oven 0 2 to 0 3 cubic foot capacity that draws about 1700 watts It will provide 3 minutes of cooking time Some induction motors used in refrigerators freezers pumps and other m...

Страница 19: ...ower red zone and cable No output voltage Thermal shutdown Improve ventilation Over Temp indicator Make sure ventilation on load less than openings in inverter 1500W are not obstructed Reduce ambient...

Страница 20: ...will be considered void if the unit has suffered any obvious physical damage or alteration either internally or externally and does not cover damage arising from improper use such as plugging The uni...

Страница 21: ...19 7 Appendix A 7 1 Dip Switch 110V S1 S2 VOUT VAC S3 FREQ Hz S5 S6 BAUD RATE ON ON 100 ON 50 ON ON 1200 OFF ON 110 OF 60 OFF ON 2400 ON OFF 115 ON OFF 4800 OFF OFF 120 OFF OFF 4800 S4 is unavailable...

Страница 22: ...1 2 The connection between this unit and a computer is as follows Computer Power Inverter RXD RXD TXD TXD DSR DTR RTS CTS GND GND 8 1 3 The RS232 interface of this unit employs ASCll code to implemen...

Страница 23: ...nd set DTR to ready for receiving more incoming information 8 2 1 The Baud Rate of the RS232 interface is determined by S5 and S6 of DIP SW as shows in Appendix A Note You have to reset the unit after...

Страница 24: ...following 0 Power saving disable 1 Power saving enable 2 Inquire the status of saving the response information would be either 0 disable or 1 enable 8 2 2 4 Power command Power ON OFF control Format P...

Страница 25: ...result be hexadecimal code replaced by 2 ASCll codes that is between 00 FF 0 255 then convert the Hex code to the binary digit after obtaining 8 bytes digit that can be one of following B0 UVP LSB B1...

Страница 26: ...obtaining a digit between 0 11 that can be one of following Hex code Decade code Indication 00 0 LED 1 glows blinking to indicate low voltage 01 1 LED 1 glows solid 02 2 LED 2 glows solid 03 3 LED 3...

Страница 27: ...or glows 02 2 Load 25 LED 1 LED 2 indicators glow 03 3 Load 35 LED 1 LED 3 indicators glow 04 4 Load 45 LED 1 LED 4 indicators glow 05 5 Load 55 LED 1 LED 5 indicators glow 06 6 Load 65 LED 1 LED 6 in...

Страница 28: ...ill be two short beep sounds from the Inverter All LEDS will be ON and one second later there will be a short Beep sound The amber green and red LEDS of remote controller will be on for 0 5 second the...

Страница 29: ...n every 2 3 seconds The color of LED will determine the mode of operation Green indicates that power saving mode is enabled and amber indicates is disabled Release the button when the LED indicating t...

Страница 30: ...om its sleep condition and restores the output power after a response time of about 8 seconds Please note that on waking up from the power saving sleep mode the inverter requires some time to prepare...

Страница 31: ...s flashing After the output power is made available the inverter searches if any load is connected If the load is less than 2 to 15 watts the output power is shut down after about 15 seconds from the...

Страница 32: ...ted 9 2 6 3 1 Switch on the inverter There will be 2 beeps and green led will start flashing with a flashing sequence of flash flash flash After about 3 seconds there will be 1 beep and the green led...

Страница 33: ...on the inverter There will be 2 beeps and green led will start flashing with a flashing sequence of flash flash flash it will flash for approx 3 seconds Immediately after it starts flashing switch off...

Страница 34: ...rica Inc 110 17 Fawcett Road Coquitlam BC V3K 6V2 Canada Toll free phone 1 800 561 5885 Toll free fax 1 888 814 5210 General Inquiries samlex samlexamerica com WWW http www samlexamerica com SA 1500_M...

Отзывы: