25
8-2-2-7. To query load level command
:
Format
:
Load?
Illustration
:
Don’t need adding any of parameter.
Respond
:
The same as BATT?
< value > can be one of following
Hex
code
Decade
code
Indication
00
0
Load < 5%, All of LED indicators go “OFF”
01
1
Load < 15%, LED 1 indicator glows.
02
2
Load < 25%, LED 1~LED 2 indicators glow.
03
3
Load < 35%, LED 1~LED 3 indicators glow.
04
4
Load < 45%, LED 1~LED 4 indicators glow.
05
5
Load < 55%, LED 1~LED 5 indicators glow.
06
6
Load < 65%, LED 1~LED 6 indicators glow.
07
7
Load < 75%, LED 1~LED 7 indicators glow.
08
8
Load < 85%, LED 1~LED 5 indicators glow.
09
9
Load < 95%, LED 1~LED 5 indicators glow.
0A
10
Load < 105%, LED 1~LED 10 indicators glow.
0B
11
Load > 105%, All of LED indicators glow
blinking to indicate over load.