12 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 13
SECTION 2 |
General Information
TABLE 2.1: INVERTER SIZING FACTOR
Type of Device or Appliance
Inverter
Sizing Factor
(See Note 1)
Air Conditioner / Refrigerator / Freezer (Compressor based)
5
Air Compressor
4
Sump Pump / Well Pump / Submersible Pump
3
Dishwasher / Clothes Washer
3
Microwave (where rated output power is the cooking power)
2
Furnace Fan
3
Industrial Motor
3
Portable Kerosene / Diesel Fuel Heater
3
Circular Saw / Bench Grinder
3
Incandescent / Halogen / Quartz Lamps
3
Ceramic / PTC type of heaters
5
Laser Printer / Other Devices using Quartz Lamps for heating
4
Switch Mode Power Supplies (SMPS): no Power Factor correction
2
Photographic Strobe / Flash Lights
4 (See Note 2)
NOTES:
1 Multiply the Running Active Power Rating {Watts} of the appliance by this Factor to arrive at
the Continuous Power Rating of the inverter for powering this appliance.
2 For photographic strobe / flash unit, the surge power of the inverter should be > 4 times the
Watt Sec rating of photographic strobe / flash unit.