38 | SAMLEX AMERICA INC.
8.4.6 DC Input Connection
The DC input terminals for battery connection (8 & 9 in Fig. 6.1) have cylindrical hole with
set screw:
- Hole size: 11 mm / .433" with M-8 set screw
DO NOT insert the stranded bare end of the wire directly into the tubular hole as the set
screw will not pinch all the strands, resulting in a partial/loose contact.
To ensure firm contact, a pair of pin type terminal lugs have been provided as follows:
• For up to AWG#1/0 or 50 mm
2
wire size (Part No. PTNB 50-20)
8.4.7 Reducing RF Interference
Please comply with recommendations given in Section 3 on page 13 - "Limiting Electro-
magnetic Interference (EMI)".
8.5 AC SIDE CONNECTIONS
WARNING! Preventing Paralleling of the AC Output
1. The AC output of the inverter cannot be synchronized with another AC
source and hence, it is not suitable for paralleling. The AC output of the in-
verter should never be connected directly to an electrical breaker panel / load
center which is also fed from the utility power/ generator. Such a connection
will result in parallel operation and AC power from the utility / generator will
be fed back into the inverter which will instantly damage the output section
of the inverter and may also pose a fire and safety hazard. If an electrical
Breaker Panel / Load Center is being fed from the utility power / generator
and the inverter is required to feed this panel as backup power source, the
AC power from the utility power/ generator and the inverter should first be
fed to a Manual Selector Switch / Automatic Transfer Switch and the output
of the Manual Selector Switch / Automatic Transfer Switch should be con-
nected to the Electrical Breaker Panel / Load Center. Samlex America, Inc.
Automatic Transfer Switch, Model No. STS-30 is recommended for this
application.
2. To prevent possibility of paralleling and severe damage to the inverter, never
use a simple jumper cable with a male plug on both ends to connect the AC
output of the inverter to a handy wall receptacle in the home / RV.