INVERTERS - GENERAL INFORMATION

Why an inverter is needed

The utility grid supplies you with alternating current (AC) electricity. AC is the standard
form of electricity for anything that “plugs in” to the utility power. Direct current (DC)
electricity flows in a single direction. Batteries provide DC electricity. AC alternates its
direction many times per second. AC is used for grid service because it is more practical
for long distance transmission. For more details read 

“Characteristics of Sinusoidal AC

Power” on page 7

An inverter converts DC to AC, and also changes the voltage. In other words, it is a
power adapter. It allows a battery-based system to run conventional AC appliances
directly or through conventional home wiring. There are ways to use DC directly, but for
a modern lifestyle, you will need an inverter for the vast majority, if not all of your loads
 (

 in electrical terms, “loads” are devices that use electrical energy

).

Incidentally, there is another type of inverter called grid-interactive. It is used to feed
solar (or other renewable) energy into a grid-connected home and to feed excess energy
back into the utility grid. This inverter is 

NOT grid interactive

Inverter should meet the application

To choose an inverter; you should first define your needs. Where is the inverter to be
used? Inverters are available for use in buildings (including homes), for recreational
vehicles, boats, and portable applications. Will it be connected to the utility grid in some
way? Electrical conventions and safety standards differ for various applications, so don’t
improvise.

Electrical Standards

The DC input voltage must conform to that of the electrical system and battery bank. 12
volts is recommended for small, simple systems. 24 and 48 volts are the common
standards for higher capacities. A higher voltage system carries less current, which makes
the system wiring cheaper and easier.

The inverter’s AC output must conform to the conventional power in the region in order
to run locally available appliances. The standard for AC utility service in North America
is 120 and 240 Volts at a frequency of 60 Hertz (cycles per second). In Europe, South
America, and most other places, it is 230 volts at 50 Hertz.

Power capacity

 

– “Continuous” and “Surge”

How much load can an inverter handle? Its power output is rated in Watts. Read details
under 

“Characteristics of Sinusoidal AC Power” on page 7. 

 There are two levels of

power rating -a 

continuous rating

 and a 

surge rating

. Continuous means the amount of

power the inverter can handle for an indefinite period of hours. When an inverter is rated
at a certain number of Watts, that number generally refers to its continuous rating. The

“surge power”

 indicates the power to handle instantaneous overload of a few seconds to

provide the higher power required to start certain type of devices and appliances.

Page 4

Содержание PSE-24125A

Страница 1: ...Owner s Manual Please read this manual before operating your Inverter DC AC Inverters PSE 24125A PSE 24175A PSE 24275A...

Страница 2: ...s that may not Operate Correctly with Modified Sine Wave Inverters 12 Limiting Electromagnetic Interference 13 Layout 14 Features Controls and Indications 15 16 Specifying Batteries Chargers andAltern...

Страница 3: ...entilation do not install in a low clearance compartment Preventing fire and explosion hazards Working with the inverter may produce arcs or sparks Thus the inverter should not be used in areas where...

Страница 4: ...AC power This may lead to overloading overheating of the neutral conductor and is a risk of fire A split phase transformer isolated or auto transformer of suitable wattage rating 25 more than the watt...

Страница 5: ...ble for use in buildings including homes for recreational vehicles boats and portable applications Will it be connected to the utility grid in some way Electrical conventions and safety standards diff...

Страница 6: ...r will further limit its ability to start a motor A battery bank that is undersized in poor condition or has corroded connec tions can be a weak link in the power chain The inverter cables and the bat...

Страница 7: ...VAC To obtain 240 VAC from a 120 VAC inverter use a 120 VAC to 240 VAC transformer If you do not already have a pump installed you can get a 120 volt pump if you don t need more than 1 2 HP Idle powe...

Страница 8: ...d for resistive type of loads that have unity 1 Power Factor In a reactive type of load like electric motor driven loads florescent lights computers audio video equipment etc the phase of the sine wav...

Страница 9: ...ected to earth Examples are the neutral conductor in AC wiring and the negative conductor in many DC systems A grounded system is a system in which one of the current carrying conductors is grounded A...

Страница 10: ...ected to a black current carrying conductor which is also called Line Live Hot pole The other flat pin is connected to the white current carrying conductor also called the Neutral Return Cold pole The...

Страница 11: ...nection that connects to the ground rod or to the water pipe or to another connection that is solidly bonded to the earth ground The connections must be tight against bare metal Use star washers to pe...

Страница 12: ...the value of the above high voltage See the diagram below The output wave form of the inverter is a modified sine wave see the diagram given below In a sine wave the voltage rises and falls smoothly...

Страница 13: ...ance of low frequency filter capacitors power factor improvement capacitors NOTE Electric motors and microwaves will run hotter when operated with modified sine wave Please ensure proper ventilation f...

Страница 14: ...pon a number of factors external to the power supply like proximity of the inverter to the EMI receptors types and quality of connecting wires and cables etc EMI due to factors external to the inverte...

Страница 15: ...Page 14 LAYOUT g f PSE 24125A PSE 24175A Rear View Bottom View a c d e b h i PSE 24275A Front View b a c d e k j f g h i Rear View...

Страница 16: ...erature LED Indicator Light This light will turn RED and the inverter will automatically shut down when the internal temperature exceeds the designed parameters for safe operation When this occurs tur...

Страница 17: ...ed as an accessory Use this receptacle if you require power to be drawn from the front panel This will require connection As this receptacle e is fed through a 15A breaker j the power drawn from here...

Страница 18: ...of deep cycle lead acid batteries wet and sealed A wet cell battery has a high tolerance to overcharg ing However it will release hydrogen gas when charging that must be properly vented and the water...

Страница 19: ...is not linear but is more or less according to the table below Table 1 Battery Capacity versus Rate of Discharge Hours of Discharge Usable Capacity 20 100 10 87 8 83 6 75 5 70 3 60 2 50 1 40 Using th...

Страница 20: ...l connection of batteries When two or more batteries are connected in series their voltages add up but their AH capacity remains the same For example when two 12 V 105 AH batteries are connected in se...

Страница 21: ...formula 2 above the DC current to be delivered by the 24 V batteries 1000 W 20 50 Amperes Next the energy required by the load in Ampere Hours AH is determined For example if the load is to operate fo...

Страница 22: ...of batteries through a battery isolator of appropriate capacity The battery isolator is a solid state electronic circuit that will allow the alternator to charge the two sets of batteries when the eng...

Страница 23: ...are isolated from the chassis Similarly the neutral pole of the AC receptacles the neutral wire is not bonded to the chassis System grounding to suit the national local electrical codes is to be unde...

Страница 24: ...to reduce the risk of dropping a metal tool on the battery It could spark or short circuit the battery or other electrical parts and could cause an explosion Remove metal items like rings bracelets an...

Страница 25: ...stranded copper wire cables rated at 90 C minimum Do not use aluminium cable as it has higher resistance per unit length Cables can be bought at a marine welding supply store The cables from the batt...

Страница 26: ...e DC side cables To further reduce RF interference shield the cables with sheathing copper foil braiding Taping battery cables together to reduce inductance Do not keep the battery cables far apart In...

Страница 27: ...therefore not a neutral Do not touch this slot as it will be at an elevated voltage with respect to the metal chassis earth ground and may produce an electrical shock when touched AC output connection...

Страница 28: ...tal Use star washers to penetrate paint and corrosion Grounding of PSE 24275A to earth or to other designated ground Please see details regarding grounding under AC Power Distribution and Grounding on...

Страница 29: ...ill be indicated It should read between 24 to 26 volts if the batteries are fully charged Switch on the AC load s The green LED bar graph current indicator d will show the current drawn by the inverte...

Страница 30: ...ge at the DC input terminals will be lower than the voltage at the battery terminals due to the voltage drop in the battery cables and connectors The drop in the voltage at the DC input terminals of t...

Страница 31: ...per limit the AC output of the inverter is shut down temporarily The red Over Temp LED b is lighted and a buzzer is sounded The unit will automatically reset after the unit has cooled down Shut down d...

Страница 32: ...the cause of the shut down REMEDY 1 Check the continuity of the battery input circuit 2 Check that the battery fuse is intact Replace if blown 3 Check that all connections in the battery input circui...

Страница 33: ...ture or insufficient air exchange REMEDY 1 Reduce the load 2 The load is not suitable as it requires higher power to operate Use an inverter with higher power rating 1 Reduce the load 2 The load is no...

Страница 34: ...for connection to external distribution panel Receptacle NEMA 5 15R Dimensions W x D x H mm Weight Kg This is the active power for resistive type of loads which have power factor 1 Reactive loads may...

Страница 35: ...a reasonable number of opportunities to do so Warranty service shall be performed only by the Warrantor Any attempt to remedy the defect by anyone other than the Warrantor shall render this warranty v...

Страница 36: ...604 525 3836 Fax 604 525 5221 Website www samlexamerica com Head Office Samlex America Inc 103 4268 Lozells Ave Burnaby BC Canada V5A 0C6 USA Shipping Warehouse Kent WA Canadian Shipping Warehouse Del...

Отзывы: