18
Warning!
Batteries with cell connection may NOT be charged.
Explosive gases could result from battery overheating.
Note
Only use cables with the designated wire cross sections to connect the charger to the battery.
Model No.
Supply battery
WSC-1230, WSC-1230SB
AWG # 10 ~ AWG # 8
WSC-1215, WSC-1215SB, WSC-2415
AWG # 12 ~ AWG # 10
WSC-2408
AWG # 14 ~ AWG # 12
Switch 1
Switch 2
I phase voltage
Uo phase voltage
U phase voltage
OFF
OFF
13.5V/27.0V
14.0V/28.0V
13.5V/27.0V
OFF
ON
13.5V/27.0V
14.4V/28.8V
13.5V/27.0V
ON
OFF
13.8V/27.6V
14.4V/28.8V
13.8V/27.6V
ON
ON
13.8V/27.6V
14.8V/29.6V
13.8V/27.6V
7
Making Connections
8 Settings
ENG
8.1 Charging voltage setting
The switch field S1 can be used to select the charging voltage, equalization voltage, charging
time and the operation mode of this charger (see Figure 11 Switch, Page. 7).
Warning!
Please follow the table below to ensure correct operation of the charger
Settings for the charging voltage for WSC-1215, WSC-1215SB, WSC-1230,
WSC-1230SB, WSC-2408 and WSC-2415:
Table 8-1 Switch Configure Charging Voltage
Table 8-2 Switch Configure Equalize Voltage
Switch 3
Equalization voltage
OFF
Same as Uo phase voltage
ON
15.5V/31.0V
Содержание WSC-1230
Страница 3: ...3 Figure 4 WSC 1215 WSC 2408 Charger Top View mm Figure 3 Charger Rear View...
Страница 4: ...4 Figure 6 WSC 1230 WSC 2415 Charger Top View mm Figure 5 WSC 1215 WSC 2408 Charger Side View mm...
Страница 5: ...5 Figure 8 Making Connections Figure 7 WSC 1230 WSC 2415 Charger Side View mm...
Страница 6: ...6 Figure 9 Cable Setup Figure 10 Fork...
Страница 7: ...7 Figure 12 Temperature Sensor TF 100 Figure 11 Switch...
Страница 8: ...8 Figure 14 Remote Controller RC 600 Dimension mm Figure 13 Remote Controller RC 600...
Страница 9: ...9 Figure 16 Remote Controller RC 601D Dimension mm Figure 15 Remote Controller RC 601D...
Страница 10: ...10 Figure 18 Temperature Sensor Setup Figure 17 Making Connections RC 601D...
Страница 31: ...www samlex com www samlex solar com...