background image

2 YEAR Limited Warranty 

The sinewave inverter manufactured by Samlex Europe B.V. ( the “ Warrantor “ )
is warranted to be free from defects in workmanship and materials under normal use and 
service. This warranty is in effect for 2 years from the date of purchase by the user 
( the “ Purchaser “)

For a warranty claim, the Purchaser should contact the place of purchase to obtain a 
Return Authorization Number. 

The defective part or unit should be returned at the Purchaser’s expense to the 
authorized location. A written statement describing the nature of the defect, the date 
of purchase, the place of purchase, and the Purchaser’s name, address and 
telephone number should also be included. 

If upon the Warrantor’s examination, the defect proves to be the result of defective 
material or workmanship, the equipment will be repaired or replaced at the Warrantor’s 
option without charge, and returned to the Purchaser at the Warrantor’s expense. 

No refund of the purchase price will be granted to the Purchaser, unless the Warrantor 
is unable to remedy the defect after having a reasonable number of opportunities to do so. 

Warranty service shall be performed only by the Warrantor. Any attempt to remedy the 
defect by anyone other than the Warrantor shall render this warranty void. There shall 
be no warranty for defects or damages caused by faulty installation or hook-up, abuse 
or misuse of the equipment including exposure to excessive heat, salt or fresh water 
spray, or water immersion. 

No other express warranty is hereby given and there are no warranties which extend 
beyond those described herein. This warranty is expressly in lieu of any other expressed 
or implied warranties, including any implied warranty of merchantability, fitness for the 
ordinary purposes for which such goods are used, or fitness for a particular purpose, 
or any other obligations on the part of the Warrantor or its employees and representatives. 

There shall be no responsibility or liability whatsoever on the part of the Warrantor or its 
employees and representatives for injury to any persons, or damage to person or persons, 
or damage to property, or loss of income or profit, or any other consequential or resulting 
damage which may be claimed to have been incurred through the use or sale of the 
equipment, including any possible failure of malfunction of the equipment, or part there of. 

The Warrantor assumes no liability for incidental or consequential damages of any kind. 

                                                  WWW.SAMLEX.COM
                                           WWW.SAMLEX-SOLAR.COM

page 31

Содержание PST-100S-12E

Страница 1: ...S 12E PST 100S 24E PST 150S 12E PST 150S 24E PST 200S 12E PST 200S 24E Model No PURE SINEWAVE INVERTER OWNER S MANUAL Please read this manual before operating your inverter Switch Mode Pure Sinewave I...

Страница 2: ...Grounding 9 10 Limiting Electromagnetic Interference EMI 10 Powering direct embeded SMPS 11 Principle of Operation 12 Layout 11 Specifying Batteries Chargers and Alternators 14 15 16 17 Installation 1...

Страница 3: ...n do not install in a low clearance compartment Preventing fire and explosion hazards Working with the inverter may produce arcs or sparks Thus the inverter should not be used in areas where there are...

Страница 4: ...f the inverter to a handy wall receptacle in the home RV Preventing input over voltage It is to be ensured that the input voltage of the inverter does not exceed 16 5VDC for 12V version or 33 VDC for...

Страница 5: ...Where is the inverter to be used Inverters are available for use in buildings incuding homes for recreational vehicles boats and portable applications Will it be connected to the utility grid in some...

Страница 6: ...her limit its ability to start a motor A battery bank that is undersized in poor condition or has corroded connections can be a weak link in the power chain The inverter cables and the battery interco...

Страница 7: ...ut causing lights to dim or blink Idle power Idle power is the consumption of the inverter when it is on but no loads are running It is wasted power so if you expect the inverter to be on for many hou...

Страница 8: ...Power Factor In a reactive type of load like electric motor driven loads fluorescent lights computers audio video equipment etc the phase of the sine wave form of the current drawn by load may lead o...

Страница 9: ...ility supplied electricity Inductive loads like microwaves and motors run faster quieter and cooler Reduces audible and electrical noise in fans fluorescent lights audio amplifiers TV fax and answerin...

Страница 10: ...nductor that does not normally carry current except under fault conditions and is also connected to earth It is used to connect the exposed metal surfaces of electrical equipment together and then to...

Страница 11: ...ar was hers to penetrate paint and corrosion The inverter contains internal switching devises which generate conducted and radiated electromagnetic interference EMI The magnitude of EMI is limited to...

Страница 12: ...o 4 This will mean that for a particular rated RMS current applicable for a linear load the general purpose SMPS will draw much larger peak currents approx up to 4 times more than its rated current In...

Страница 13: ...he fuse inside the inverter and may cause permanent damage Ensure that the cigar lighter socket used for powering the inverter has the correct polarity with respect to the cigar lighter plug s positiv...

Страница 14: ...t and sealed A wet cell battery has a high tolerance to overcharging However it will release hydrogen gas when charging that must be properly vented and the waterlevel must be checked frequently Seale...

Страница 15: ...ip is not linear but is more or less according to the table below Table 1 Battery Capacity versus Rate of Discharge Hours of Discharge Usable Capacity 20 100 10 87 8 83 6 75 3 60 2 50 1 40 Using the a...

Страница 16: ...onnection of batteries When two or more batteries are connected in series their voltages add up but their AH capacity remains the same For example when two 12 V 105 AH batteries are connected in serie...

Страница 17: ...d by the inverter 1000W Then using formulae 2 above the DC current to be delivered by the 12 V batteries 1000W 10 100 Amperes Next the energy required by the load in Ampere Hours AH is determined For...

Страница 18: ...to these two sets of batteries through a battery separator of appropriate capacity The battery separator is a device that will allow the alternator to charge the two sets of batteries when the engine...

Страница 19: ...rain snow or liquids of any type To reduce the risk of overheating and fire do not obstruct the suction and discharge openings of the cooling fan To ensure proper ventilation do not install in a low c...

Страница 20: ...tages generated during conditions of high winds for wind generators high water flow rates for hydro generators or cold temperatures for solar panels It is therefore to be ensured that the diversion lo...

Страница 21: ...ate capacity in line with the positive cable The fuse should be within 50 cm from the battery The following size of cables and fuse are recommended The distance shown is the distance between the batte...

Страница 22: ...e battery cables far apart In case it is not convenient to twist the cables keep them taped together to reduce their inductance Reduced inductance of the battery cables helps to reduce induced voltage...

Страница 23: ...nt 5mA Grounding to earth or to other designated ground Please see details regarding grounding under AC Power Distribution and Grounding on page 9 For safety the metal chassis of the inverter is requi...

Страница 24: ...the DC side circuit will still be alive even when the switch is in the off position Hence disconnect the DC and AC sides before working on any circuits connected to the inverter When the inverter is...

Страница 25: ...E When the inverter is turned off using the optional Remote Control RC 15 only the final output section is turned off The rest of circuits are still in standby condition Hence even in this off conditi...

Страница 26: ...it has been permanently damaged Shut down due to over temperature In case of failure of the cooling fan or in the case of inadequate heat removal due to higher ambient temperatures insufficient air e...

Страница 27: ...t over the required length Use thicker cables if required 3Tighten connections of the battery input circuit TROUBLESHOOTING GUIDE SYMPTOM On switching on the green LED does not light Buzzer is off The...

Страница 28: ...ove the cause of the shut down 1 Check that the fans are working If not the fan fan control circuit may be defective Call Technical support 2 If the fans are working check that the ventilation slots o...

Страница 29: ...have power factor of 0 8 to 0 6 The power that can be delivered to such type of loads will reduce by this factor See page 7 for details Low Input Voltage Warning Alarm 10 7 V 21 4 V Low Input Voltage...

Страница 30: ...power factor of 0 8 to 0 6 The power that can be delivered to such type of loads will reduce by this factor See page 7 for details Low Input Voltage Warning Alarm 10 7 V 21 4 V Low Input Voltage Shut...

Страница 31: ...power factor of 0 8 to 0 6 The power that can be delivered to such type of loads will reduce by this factor See page 7 for details Low Input Voltage Warning Alarm 10 7 V 21 4 V Low Input Voltage Shut...

Страница 32: ...ly by the Warrantor Any attempt to remedy the defect by anyone other than the Warrantor shall render this warranty void There shall be no warranty for defects or damages caused by faulty installation...

Страница 33: ...www samlex com www samlex solar com...

Отзывы: