REMEDY
1 Check the continuity of the battery
input circuit.
2 Check that the battery fuse is intact.
Replace if blown
3 Check that all connections in
the battery input circuit are tight
Visibly check the fuse element if it is
blown. The fuses are solderd and are
not easily replaceble.Call Technical
Support for repair.
1 Check that the battery is fully
charged. Recharge, if low
2 Check that the battery cables are thick
enough to carry the required current
over the required length. Use thicker
cables, if required.
3 Tighten connections of the battery
input circuit
4 Reduce the load
1 Check that the battery is fully charged.
Recharge, if low
2 Check that the battery cables are thick
enough to carry the required current
over the required length. Use thicker
cables, if required.
3Tighten connections of the battery
input circuit
1 Check that the battery is fully
charged. Recharge, if low
2 Check that the battery cables are thick
enough to carry the required current
over the required length. Use thicker
cables, if required.
3Tighten connections of the battery
input circuit
TROUBLESHOOTING GUIDE
SYMPTOM
On switching on, the green
LED does not light.
Buzzer is off.
There is no AC voltage
Low AC output voltage
(No buzzer alarm)
Buzzer alarm is sounded
when load is switched on.
Voltage at DC input
terminals reads between
10 and 10.7 V for 12 V
version or between 20
to 21.4V for 24V version
Green LED is on. AC output
voltageis available.
Buzzer alarm is sounded
when load is switched on.
Voltage at the DC input
terminals reads below
10 to 10.7V for 12V
version or 20 to 21.4V
for 24V version. Green LED
is off There is no AC output.
POSSIBLE CAUSE
There is no voltage at
the DC input terminals
Polarity of the input voltage
has been reversed that has
blown the internal DC side
fuses (note: Reverse polarity
may cause permanent damage)
Low input voltage at the
inverter terminals and the
load is close to the maximum
allowable power
DC input voltage is
less than 10.7V for
PST-200S-12A or less
than 21.4 V for
PST-200S-24A
.
Shut-down due to low
input DC voltage (Less
than 10V for 12V
version or less than 20V for
24V version.)
page 26
Содержание PST-100S-12E
Страница 33: ...www samlex com www samlex solar com...