background image

SAMIL POWER

Expert for PV Grid-tied Inverters

TM

SP-SR-D-V1.0-EN

SolarRiver-D PV Grid-tied Inverter

Product Manual

English

Solar

R

R

i

iver-

D

P

P

V

G

Gr

i

i

d

d-

t

t

i

ie

d

I

Inver

t

ter

Product Manual

Содержание SolarRiver 3400TL-D

Страница 1: ...SAMIL POWER Expert for PV Grid tied Inverters TM SP SR D V1 0 EN SolarRiver D PV Grid tied Inverter Product Manual English SolarR Ri iver D D P PV V G Gri id d t ti ied d I Invert ter Product Manual...

Страница 2: ......

Страница 3: ...partially copy or fully copy it including software etc and should not reproduce or distribute it in any form or by any means All rights reserved Samil Power reserves the right of final interpretation...

Страница 4: ...02...

Страница 5: ...5 7 1 Announcements 5 7 2 PV array connection types 5 7 3 Connection steps of DC connector 5 7 4 Assembly steps of AC connector 5 7 5 Grounding 5 7 6 Connection of communication 5 1 Installation proce...

Страница 6: ...9 40 39 11 Technical Data 41 12 Guarantees 8 1 Communication Interface 8 2 Communication mode 8 2 2 RS485 Communication 8 2 3 WIFI communication 8 2 1 Ethernet communication 8 2 4 GPRS communication 2...

Страница 7: ...e visit the company website www samilpower com for more information 1 4 Symbols Used There are some symbols in this manual in order to ensure personal and property security Please read the following s...

Страница 8: ...d electric shock make sure that existing wiring is in good condition and wire is not undersized Do not operate the SolarRiver D Series inverter with damaged or substandard wire Do not disassemble the...

Страница 9: ...d each individual MPPT can improve the efficiency of the system MPPT range is wide so expanding the voltage range This feature adapts to the current trend which voltage of PV is reduced and the system...

Страница 10: ...rRiver D series inverter 08 Figure 2 Electrical block diagram of SolarRiver D series inverter N PV Insulation Detection DSP B DSP A PE RCMU ARM LCD Ethernet MPPT1 DC DC MPPT2 DC DC DC BUS Inverter DC...

Страница 11: ...ver D series inverter 09 3 5 Terminals of inverter 3 6 Dimension Figure 4 Terminals of PV inverter Figure 5 Dimension AC Output Antenna LAN Relay RS 485 Venting Element DC Input LAN RS 485 RS 485 AC D...

Страница 12: ...IP65 Ingress protection 20 60 C Operating temperature range Protective class Class Communication Type RS485 outdoor IP65 Ingress protection 20 60 C Operating temperature range Protective class Class...

Страница 13: ...are for installation If find some damage or some missing please contact Samil Power s sales Installation 11 Mechanical installation refer to 5 6 Work during mechanical installation Fix the panel of i...

Страница 14: ...ny case The largest input current of MPPT circuit in any case Must observe the following standard and specifications strictly when installing operating and maintaining SolarRiver D series inverter Get...

Страница 15: ...ntenna or antenna cable The inverter is needed at least 30 cm see figure 8 clearance If not observe this there will be malfunction of the system caused by water or high temperature inside the inverter...

Страница 16: ...g to the size of bracket Keep drilling perpendicular to the wall and don t shake when drilling to avoid damage to the wall Then put expansion pipe into the hole use rubber hammer to tap the pipe into...

Страница 17: ...inverter onto the bracket Step 3 Use M5 hex key nut to fix the bottom of the inverter Step4 Lock the inverter and the bracket with lock for safety This is optional for users User can select the lock a...

Страница 18: ...e PV array connection types There are 2 independent MPP trackers in inverter You can choose common string input connection and multi strings input connection We recommend that choose multi strings to...

Страница 19: ...humb or using combination pliers Please ensure that the spring is closed see figure 11 Step3 Push connectors together see figure11 Screw cable gland tight Screw in the nut until it reaches the O ring...

Страница 20: ...gure 13 Incorrect Connections between Load and Inverter 18 Input Output ESC OK Impedance of SolarRiver D inverter AC connector should be less than 2 To ensure anti islanding function reliable wire los...

Страница 21: ...ough the threaded sleeve and pressure screw Step2 Wire the AC side refer to following instructions Screw the green yellow wire to the ground terminator in the AC Connector Screw the N wire blue wire t...

Страница 22: ...ormer or it wil break down In the system all non current carrying metal parts such as shell of combiner distribution and inverter should be connected to the earth Figure 16 grounding of system 5 7 6 C...

Страница 23: ...n of inverter AC side Ensure that the breaker of inverter AC side is OFF Measure THD total harmonic distortion possibly then check the curve If it is distorted seriously the inverter can not run 6 2 S...

Страница 24: ...3 Date and time settings Set according to the local date and time Press left or right arrow key to move the cursor press the up or down arrow keys to change value then press OK to confirm LCD will dis...

Страница 25: ...mation is correct please press OK to confirm the inverter will save all the settings 23 Date Time Press OK to confirm 0 0 1 2 2 3 0 3 1 0 1 0 0 DD DD MM MM hh hh mm mm YYYY YYYY Up Down Increase Decre...

Страница 26: ...or or fault occurs inverter will go to Fault State or Permanent State fault Inverter has checked some recoverable error It can recover if the error disappears If in Fault State continually you should...

Страница 27: ...put output voltage current power temperature and other real time information 7 2 4 Historical data Move the cursor to the History and then press OK the user will see the power amount histogram of ever...

Страница 28: ...ings interface Some settings need to input password There are 3 kinds of password user password installation password and factory password You can enter Clear data Clear events Network and Reset passw...

Страница 29: ...state such as output voltage current frequency fault information GPRS Inform message by message Only choose one optional configuration when inverter is working 8 2 Communication mode When user want t...

Страница 30: ...ngs and then press OK will enter settings interface Home 2012 03 03 10 00 00 Press Esc to Main Menu Power Today Total 0 0 W 0 0 KWh 0 0 KWh 208 4 V 205 9 V 1 045 kw 49 99 Hz t kwh Instantaneous values...

Страница 31: ...or 1 inverter Need to use cable to connect inverter with PC Parameter setting when not using router Refer to settings when using router Main Menu Settings Network Ethernet In Ethernet interface move t...

Страница 32: ...OK to confirm Auto IP DHCP Manud IP Current mode Manual IP Ethernet 2012 03 03 10 22 50 Confirm Auto IP DHCP Manud IP Current mode Manual IP Manual IP 2012 03 03 10 26 05 Press OK to confirm Up Down I...

Страница 33: ...e between inverter and inverter 1 Prepare two 8 PIN RJ45 modular plug hold the RJ45 modular plug with the clip on the bottom the opening where you insert the cable facing you the order number is 1 to...

Страница 34: ...orange white orange as shown in figure 25 Figure 25 2 Connect 4 colour wires to 1 4 5 6 port of Solar Log 8 2 3 WIFI communication You can connect inverter to Internet by router Then you can see the i...

Страница 35: ...tion page Set the SSID of router which WIFI is going to be connected to and input the password known from installation contractor then save these information Step3 Reboot the computer automatically an...

Страница 36: ...at sends fault message to user when inverter is at fault Hardware Requirements SIM card inverter equipped with GPRS mobile telephone Monitor mode message GPRS settings Step1 Use mobile telephone to se...

Страница 37: ...hen save these information Step4 Reboot the computer automatically Step5 Check GPRS information Enter the interface successively Main Menu Settings Network move the cursor to GPRS and press OK If GPRS...

Страница 38: ...ements Is the inverter installed in a clean dry adequately ventilated place Have the DC input switch been opened Do section area and length of cable meet requirements Are the input and output connecti...

Страница 39: ...over 30mA 60mA 150mA 300mA fault Check whether leakage current is too high Disconnect DC and AC side check the surrounding equipment on the AC side Reconnect the input side and check inverter after t...

Страница 40: ...ater corrosive chemical substance or intense cleaning agent is not allowed 10 Decommissioning 10 1 Decommissioning steps 1 Switch off the AC grid 2 Switch Off the DC switch 3 Wait 5 minutes 4 Release...

Страница 41: ...0 2750 2750 3000 3000 3100 3100 2 1 12 12 13 5 13 5 15 15 15 15 4000 4500 5000 5200 550 0 8lagging 0 8leading 3 50 47 52 Model SolarRiver 3400TL D SolarRiver 4000TL D SolarRiver 4500TL D SolarRiver 50...

Страница 42: ...ty Use SolarRiver D inverter for other purpose Install incorrectly or not conform to the rule Improper operation Useunqualified protection when working Modify the equipment without authority Damage be...

Страница 43: ...F7D1401 v1 Belkin Wireless Modem Router F7D2401 v1 F7D2401 B v1 Belkin Modem Router F7D3402 v1 Surf Wireless Router F7D2301 Share Max Wireless Router F7D3301 Surf N300 Wireless N Router F7D2301 V3000...

Страница 44: ...0 HOME ROUTER DIR 600 V B4 DIR 600 V B4 DIR 815 Wireless N Dual Band Router DIR 815 v1 00 DIR 815 v1 00 Wireless N 8 port router DIR 632 IEEE 802 11 Wireless N 150 Home Router DIR 501 DIR 501 IEEE 802...

Страница 45: ...4 v9 Proxim Orinoco AP 700 Orinoco AP 700 Proxim ORiNOCO AP 600 TP Link 150Mbps Wireless Lite N Router TL WR740N 150Mbps Wireless Lite N Router TL WR741ND 300Mbps Wireless N Router TL WR841N TP LINK W...

Страница 46: ......

Страница 47: ......

Страница 48: ...vince P R China 214174 Tel 86 510 83593131 Fax 86 510 81819678 E mail service samilpower com http www samilpower com Factory Add No 66 Taihangshan Road Suyu Economic Development Zone Suqian City Jiang...

Отзывы: