4.2.3. Raccordement de la gaine de ventilation
Connect the
∅
220 mm ventilation duct with
∅
236 mm dropped edge to the duct of the customer's filter unit using
a suitable hose clamp.
4.2.4. Vibrrating table
Remove the locking plate for carrying the vibrating table.
4.2.5. Ground connection
The various equipment of the powder station requiring grounding are connected to the grounding bars located on
the frame at the back of the powder station.
It is imperative to connect the grounding bars of the control unit to the grounding bar of the
control cabinet or to a factory or building earth.
4.2.6. Sensitivity adjustment of powder level sensors
• Raise the powder level above the sensor and adjust
the setting screw with a small flathead screwdriver
until the indicator light on the amplifier tilts.
• Bring the powder level back down below the sensor
and check that the light is off.