![SAMES KREMLIN PPH 707 CHEM ICWB M TI Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/sames-kremlin/pph-707-chem-icwb-m-ti/pph-707-chem-icwb-m-ti_user-manual_3687715038.webp)
Index revision : A
38
7116
6.3.8.
Procedure E2: Replacement of fittings
•
Remove the air fitting from the hose:
Hold
the hose using tool P/N 1313955, insert the
hose in the orifice corresponding to the hose
diameter, and loosen using a flat wrench with
diameter corresponding to the fitting diameter.
•
Remove the product fitting:
Loosen the nut
while holding the fitting with two flat wrenches,
then withdraw the fitting from the tube by pulling
along the axis (slighlty rotating the fitting).
• To merely replace the fitting, cut the hose
approximately 20 mm from its end using the
tube cutter (P/N W3SCTU002). Caution: The
cutting plane must be perfectly perpendicular to
the hose.
Reinstallation of fittings:
•
Air fitting
:
Push the hose into the fitting and
tighten securely (for fittings P/N 910002946,
910002947, 910002948 and 910004923).
•
Product fitting
: For screwed fittings (P/N
910003345 and 910002950), fit the nut on the
hose, push the hose onto the fitting body until
the shoulder, and tighten the nut.
For the fitting (P/N 910003413) proceed as the
air fittings.
Nut
Fitting body