![SAMES KREMLIN PPH 707 CHEM ICWB M TI Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/sames-kremlin/pph-707-chem-icwb-m-ti/pph-707-chem-icwb-m-ti_user-manual_3687715037.webp)
Index revision : A
37
7116
6.3.7. Procedure E1: Hose replacement
•
Hose replacement:
It is not necessary to separate the quick-dis-
connect plate from the rear support in order to
access the fittings or hoses or remove the
cover.
• Position tool P/N # 900002665 on the fitting.
Screw.
• Withdraw the fitting by pulling it along the axis
using the tool.
•
To replace the hose,
use the old hose as a needle and pull the assembly until the new hose pro-
trudes from the quick-disconnect plate.
WARNING : When replacing a hose, ensure that there is sufficient length for disassembly at a
later stage. The hoses must be secured so that they cannot be torn out.
WARNING : Replace all hoses every 12 to 24 months, depending on the amount of use.
DES03969
For 6/8 dia. fit-
tings
For 2.7/4 and 4/6
dia. fittings