3.  OPERATION 

The M 250 and M 350 guns may be used with or without extension poles length 300 or 600 mm (+ 900 

or 1800 mm for MP 200 handle) with an angle head or not. 
The projector is composed of : base (hand-tight or wrench-tight), tip (reversing or flat). 
For MP 200 handle a selection of rollers (9" x 1/2" - 9" 3/4" - 9" 3/8") is available to be fitted directly to 

the handle or at the extremity of a 900 or 1800 mm extension pole. 

4.  SERVICING 

Before doing any service work on gun, installing or removing spray tip or filter…, : 
-  Shut off the pump air pressure, 
-  Lock the gun trigger with the safety device, 
-  Relieve pressure from circuit by opening pump pressure relief valve, 
-  Carefully loosen gun swivel slightly to relieve any residual pressure. 

  Never work on gun when connected to hose. 

Always engage trigger lock-off when gun is not spraying. 

 

COMPLETE BALL VALVE PLUNGER ASSEMBLY (M 250) REPLACEMENT  

(REFER TO DOC. 573.173.050) 

Unscrew base (1) then valve seat (2) - wrench # 19.  
Unsnap trigger guard (3) from bottom of gun handle (7). 
Unscrew nut (25) (use wrench provided with the gun), remove push rod tree (24) and push rods 

(22 and 23). 
Push ball valve assembly (4) from rear to remove it. Lubricate with vaseline. 
Replace ball valve assembly (4) and valve seat (2) with new ones. Reassemble the gun by 

following the previous operations in the reverse order. 
Screw on nut (25) until one thread is showing through the nut 

  do not force past this point. 

However, if nut is not screwed in far enough, improper trigger adjustment will result. By screwing 

valve seat (2) push rod tree (24) must lightly move back. 

 

COMPLETE BALL VALVE PLUNGER ASSEMBLY (M 350) REPLACEMENT 

Unscrew base (1) and nut (28) in seat (29) with the wrench provided. 
Unsnap trigger guard (3) from bottom of gun handle (7). 
Unscrew nut (25) (use wrench provided with the gun), remove push rod tree (24) and push rods 

(22 + 23). 
Push ball valve assembly (30) from rear to remove it. Lubricate with vaseline. 
Replace ball valve and seat assembly (30) with new one. 
Reassemble the gun by following the previous operations in the reverse order. 
Hand tighten retainer nut (28) (in the seat 2), tighten nut (25) then pull trigger back and tighten 

retainer nut with wrench provided.  

 

GUN FILTER (M 250 / M 350) REPLACEMENT 

Remove gun swivel (7) from the gun. Unsnap trigger guard (3) from bottom of gun handle. 
Unscrew gun handle (20) and remove gun filter (19). Clean or replace filter (19). 
Lubricate threads with vaseline and tighten gun handle (20) (using wrench if necessary). 

Содержание M 250

Страница 1: ...50 AIRLESS MANUAL SPRAY GUNS MP 200 AIRLESS HANDLE Manual 0501 573 187 112 Date 3 01 05 Supersede 573 077 112 Modif up to date SAMES KREMLIN SAS l 13 chemin de Malacher 38 240 MEYLAN France 33 0 4 76 41 60 60 www sames kremlin com ...

Страница 2: ...ssets of 6 720 000 Euros Head office 13 chemin de Malacher 38 240 MEYLAN France Tel 33 0 1 49 40 25 25 Fax 33 0 1 48 26 07 16 Herewith declares that Spray gun is in conformity with EC Maquinery Directive Directive 98 37 EC as amended and with national implementing legislation Established in Stains on March 1st 2003 Daniel TRAGUS President 2 SAFETY INSTRUCTIONS WARNING Any misuse of the equipment o...

Страница 3: ...our times the maximum service pressure of the pump see data sheet Be certain the hoses are not crimped leaking and not unrolled Be certain the hoses are in good condition and showing no evidence of damage Use only air hose with static conductor to connect the pump with the spray gun All fittings must be tight and in good condition PUMP Interconnect the equipment with ground use the connection prov...

Страница 4: ...23 Push ball valve assembly 4 from rear to remove it Lubricate with vaseline Replace ball valve assembly 4 and valve seat 2 with new ones Reassemble the gun by following the previous operations in the reverse order Screw on nut 25 until one thread is showing through the nut do not force past this point However if nut is not screwed in far enough improper trigger adjustment will result By screwing ...

Страница 5: ...l leaks of the complete system under pressure 5 CLEANING Change material with solvent and spray until the fluid is not colored with material Remove base and tip to clean them with a brush no metallic parts and solvent Insist particularly on threads Do not keep the dipping in solvent 6 FIXING AND TIGHTNESS OF AIRLESS TIP Fixing of reversing tip on the gun is ensured by the base P N 922 562 000 Tigh...

Отзывы: