11
The 1 m / 39.37"
distance may be modified if trials carried out by the user indicate this is
necessary.
•
Using the grounding air hose, connect the gun to an air regulator that can supply
at least 3 bar / 43.5 psi.
•
Using the fluid hose, connect the gun fluid fitting to the pump. Tighten the fittings
firmly.
Note: In some particular cases, if the air hose (4) is not conductive, the fluid hose
(3) must be conductive. One of the 2 gun hoses (air or fluid) must be conductive.
6.2
Installation Diagram - Air pressure adjustment with or without
gauge at gun handle
1 - P 0 : Air pressure
(wall)
2 - Air hose
7
Storage
Our equipment must be stored in its original packaging.
In case of prolonged storage, it is preferable to carry out preventive maintenance for all
lubricants before startup.
Storage before installation
•
Storage ambient temperature 0 / +50 °C (32° F / 122° F°).
•
Protect the complete unit from dust/dirt, water/condensation, moisture, vibration
and shock.
•
Do not remove the packaging until just before assembly.
Storage after installation
•
Protect the unit from dust/dirt, water/condensation, moisture and shock.
3 - P 1: Pressure
measured at
gun grip
in the course of
operation
(air needle
open)
4 – Guns, model
FSTART Gravity