5.4.1
Appropriate cables & cable entries
An integral part of the device safety is the correct selection of the cables, wires and cable
entries.
Attention!
Cables and wires must comply with the requirements of the IEC 60079-
0/1/7 & 14.
Attention!
The supply line must have a sufficient cross-section. The cable pro-
tection must comply with national and international regulations.
For non-binding configuration and planning guidelines, please visit
our website:
5.4.2
Fusing
The power supply fusing depends on the cable cross-section and length. 300 mA mT-
fuse is recommended.
Attention!
Please pay attention to the national and international regulations regarding
selectivity and line protection.
5.4.3
Tests prior to switching on voltage
Attention!
Prior to starting the device, perform all tests as indicated by the na-
tional regulations. Furthermore, check the correct function and instal-
lation of the device in accordance with this User Manual and other ap-
plicable regulations.
Attention!
Incorrect installation or operation of the camera may lead to a loss of
warranty!
Attention!
Do not switch on the camera at temperatures below 0°C!