background image

Receive
Frequency

Receiving Status

Group Call Status

Battery Information
Battery on First Use

Since batteries leave factory without a fully charging, please charge the new batteries before using. Under normal circumstances, the
battery on first use needs 5 hours of charging. The first three times of fully charging and discharging provides batteries the best capacity.
When you find out the battery is low, it is required to charge or replace it.

Compatible Battery Type

Please use the  specific battery for the use of other batteries may cause explosion, resulting in bodily injury.

Safety Precautions

1. Do not dispose the batteries in the fire.
2. Do not dispose the batteries as household wastes, and it must be collected and treated properly.
3. Do not rip off the shell from the battery without permission.

p

y

p

Notes:

1. When charging, the temperature should be between 5

~40 

,otherwise it may cause the leakage or even damage the battery.

2. Please shut down the transceiver with battery loaded before charging it. The use of the transceiver while charging is ongoing
will affect the normal battery charging.
3. Do not put back and charge the battery that is already full, for it will significantly reduce the cycle life.
4. Since continuous charging will shorten the life of the battery, it is unwise to place the transceiver or battery on the charger, or take
the charger as a placement seat for the transceiver.
5. Do not charge the battery when it is wet. You should dry it first in order to avoid any danger.
6. If the battery’s usage time is very short even when it has been charged in completely correct way, it can be concluded that the
battery life is due and should be replaced by a new one.

Extension of Battery life

1. The performance of the battery will be reduced when the temperature drops below 0

. In cold weather, it is advised to

spare another battery for emergency. Please do not dispose the cold batteries that can not work at low temperature but may be
usable at room temperature.

Содержание FPCN30A

Страница 1: ...0A Features With GROUP button Voice commander scrambler VOX Sensitive settings With LCD Display Key Lock and Tone Setting Squelch tail elimination 20 Memory Channel Manufacture Guangdong Samzuk Techno...

Страница 2: ...ng the antenna is no less than y p p g 1 to 2 inches i e 2 5 to 5cm away from your lips when transmitting signals It is very important to keep the correct distance from the transceiver since the farth...

Страница 3: ...ergy very sensitive equipment Prohibit the use of airports and aircraft radio Medical devices Pacemaker Advanced Medical Technology Association of the United States proposes holding the handheld trans...

Страница 4: ...the battery or charge to the battery in these areas Because of such gases in the spark will cause an explosion or fire resulting in casualties Mentioned above with a potentially explosive gas areas in...

Страница 5: ...ace the original power cord and plug provided If plugs and sockets do not match please ask the qualified electrician to install an outlet to avoid electric shock 5 To avoid damage to the power cord or...

Страница 6: ...y 13 Keys 12 10 14 Battery 8 15 Belt screw 3 13 16 Charger 14 16 Press the MENU key enter into the menu selecting mod Press or key choice the function Press the GROUP OK key to speak to all channel op...

Страница 7: ...se the leakage or even damage the battery 2 Please shut down the transceiver with battery loaded before charging it The use of the transceiver while charging is ongoing will affect the normal battery...

Страница 8: ...light Green light Please do the following steps to charge State Be charging Charging completed Indicator Light g p g 1 Insert the AC plug of the power adapter into the AC power outlet 2 Insert the DC...

Страница 9: ...ket at the top of the transceiver Rotate the antenna clockwise until tightening up as shown 2 Removal of the antenna Rotate the antenna counterclockwise to remove it Installation Removal of Belt clip...

Страница 10: ...Setting content 0 19 OFF 1 9 1 9 Group channel setting Voice Operation 4 5 6 BEP CMP SCA After pressing MENU into function menu and GRP will be shown on display press OK key then you can select 0 19 t...

Страница 11: ...nu and choice SQL press OK key then you can select 1 9 through by or then press OK key again press the EXIT key to give up setting After pressing MENU into function menu and choice BEP press OK key th...

Страница 12: ...nal the LED indicator will turn green for long When the function is activated the transceiver will check whether there are calls on the channels that are set to be scanned If a channel is tested to ha...

Страница 13: ...y Users in the channel through Meun Troubleshooting Guide Battery may have been exhausted Please update or recharging the battery Battery may not be installed correctly Please remove the battery and r...

Страница 14: ...u send please get close and try again It can not reach others of a group Maintenance and Cleaning 1 Do not lift the transceiver directly by its antenna or external microphone 2 Dust the transceiver wi...

Страница 15: ...Our company reserves the right of final explanation to these commitments above...

Страница 16: ...ertification number has been approved by Industry Canada to operate with the antenna types with the maximum permissible gain indicated Antenna types not approved having a gain greater than the maximum...

Отзывы: